219 research outputs found

    Structural and Magnetic Characterization of Large Area, Free-Standing Thin Films of Magnetic Ion Intercalated Dichalcogenides Mn0.25TaS2 and Fe0.25TaS2

    Get PDF
    Free-standing thin films of magnetic ion intercalated transition metal dichalcogenides are produced using ultramicrotoming techniques. Films of thicknesses ranging from 30nm to 250nm were achieved and characterized using transmission electron diffraction and X-ray magnetic circular dichroism. Diffraction measurements visualize the long range crystallographic ordering of the intercalated ions, while the dichroism measurements directly assess the orbital contributions to the total magnetic moment. We thus verify the unquenched orbital moment in Fe0.25TaS2 and measure the fully quenched orbital contribution in Mn0.25TaS2. Such films can be used in a wide variety of ultrafast X-ray and electron techniques that benefit from transmission geometries, and allow measurements of ultrafast structural, electronic, and magnetization dynamics in space and time

    Biosensing platform combining label-free and labelled analysis using Bloch surface waves

    Get PDF
    Bloch surface waves (BSW) propagating at the boundary of truncated photonic crystals (1D-PC) have emerged as an attractive approach for label-free sensing in plasmon-like sensor configurations. Due to the very low losses in such dielectric thin film stacks, BSW feature very low angular resonance widths compared to the surface plasmon resonance (SPR) case. Besides label-free operation, the large field enhancement and the absence of quenching allow utilizing BSW coupled fluorescence detection to additionally sense the presence of fluorescent labels. This approach can be adapted to the case of angularly resolved resonance detection, thus giving rise to a combined label-free / labelled biosensor platform. It features a parallel analysis of multiple spots arranged as a one-dimensional array inside a microfluidic channel of a disposable chip. Application of such a combined biosensing approach to the detection of the Angiopoietin-2 cancer biomarker in buffer solutions is reported

    Ultrafast sublattice pseudospin relaxation in graphene probed by polarization-resolved photoluminescence

    Get PDF
    Electronic pseudospin degrees of freedom in two-dimensional materials exhibit unique carrier-field interactions which allow for advanced control strategies. Here, we investigate ultrafast sublattice pseudospin relaxation in graphene by means of polarization-resolved photoluminescence spectroscopy. A comparison with microscopic Boltzmann simulations allows us to determine a lifetime of the optically aligned pseudospin distribution of 12±2fs. This experimental approach extends the toolbox of graphene pseudospintronics, providing additional means to investigate pseudospin dynamics in active devices or under external fields

    Automated universal chip platform for fluorescence based cellular assays

    Get PDF
    Dieser Beitrag ist mit Zustimmung des Rechteinhabers aufgrund einer (DFG geförderten) Allianz- bzw. Nationallizenz frei zugänglich.This publication is with permission of the rights owner freely accessible due to an Alliance licence and a national licence (funded by the DFG, German Research Foundation) respectively.The advantage of cell based assays used as biosensors is the direct access to hardly obtainable parameters like toxicity, mutagenicity and pharmacological effectiveness. Within the last few years we established a micro fluidic platform including a peristaltic micro pump as well as several valves, manifolds and micro channels [1]. For optical online monitoring the micro fluidic system is bonded to a glass slide. Furthermore the biochip is fixed on an electrically heated support. The pneumatically actuated peristaltic pump as well as the temperature control is performed by a control device. For the fluorescence based online monitoring a robotic guided fluorescence measurement module was developed, which supports the detection of fluorescence in microtiter plates and microfluidic systems. This measurement module allows the fluorescence detection of two different excitation / detection wavelengths (480 / 530 nm and 570 / 620 nm) and was successfully characterised using EGFP and Rhodamine 6G. Additionally three cell based assays with bacterial, yeast and human cells were characterized

    Assessing Organizational Readiness for Depression Care Quality Improvement: Relative Commitment and Implementation Capability

    Get PDF
    Background: Depression is a major cause of morbidity and cost in primary care patient populations. Successful depression improvement models, however, are complex. Based on organizational readiness theory, a practice’s commitment to change and its capability to carry out the change are both important predictors of initiating improvement. We empirically explored the links between relative commitment (i.e., the intention to move forward within the following year) and implementation capability. Methods: The DIAMOND initiative administered organizational surveys to medical and quality improvement leaders from each of 83 primary care practices in Minnesota. Surveys preceded initiation of activities directed at implementation of a collaborative care model for improving depression care. To assess implementation capability, we developed composites of survey items for five types of organizational factors postulated to be collaborative care barriers and facilitators. To assess relative commitment for each practice, we averaged leader ratings on an identical survey question assessing practice priorities. We used multivariable regression analyses to assess the extent to which implementation capability predicted relative commitment. We explored whether relative commitment or implementation capability measures were associated with earlier initiation of DIAMOND improvements. Results: All five implementation capability measures independently predicted practice leaders’ relative commitment to improving depression care in the following year. These included the following: quality improvement culture and attitudes (p = 0.003), depression culture and attitudes (p \u3c0.001), prior depression quality improvement activities (p \u3c0.001), advanced access and tracking capabilities (p = 0.03), and depression collaborative care features in place (p = 0.03). Higher relative commitment (p = 0.002) and prior depression quality improvement activities appeared to be associated with earlier participation in the DIAMOND initiative. Conclusions: The study supports the concept of organizational readiness to improve quality of care and the use of practice leader surveys to assess it. Practice leaders’ relative commitment to depression care improvement may be a useful measure of the likelihood that a practice is ready to initiate evidence-based depression care changes. A comprehensive organizational assessment of implementation capability for depression care improvement may identify specific barriers or facilitators to readiness that require targeted attention from implementers

    Correlation energy of an electron gas in strong magnetic fields at high densities

    Full text link
    The high-density electron gas in a strong magnetic field B and at zero temperature is investigated. The quantum strong-field limit is considered in which only the lowest Landau level is occupied. It is shown that the perturbation series of the ground-state energy can be represented in analogy to the Gell-Mann Brueckner expression of the ground-state energy of the field-free electron gas. The role of the expansion parameter is taken by r_B= (2/3 \pi^2) (B/m^2) (\hbar r_s /e)^3 instead of the field-free Gell-Mann Brueckner parameter r_s. The perturbation series is given exactly up to o(r_B) for the case of a small filling factor for the lowest Landau level.Comment: 10 pages, Accepted for publication in Phys.Rev.

    Label-free and fluorescence biosensing platform using one dimensional photonic crystal chips

    No full text
    The increasing demand for early detection of diseases drives the efforts to develop more and more sensitive techniques to detect biomarkers in extremely low concentrations. Electromagnetic modes at the surface of one dimensional photonic crystals, usually called Bloch surface waves, were demonstrated to enhance the resolution and constitute an attractive alternative to surface plasmon polariton optical biosensors. We report on the development of Bloch surface wave biochips operating in both label-free and fluorescence modes and demonstrate their use in ovalbumin recognition assays

    Identifying quality improvement intervention publications - A comparison of electronic search strategies

    Get PDF
    Abstract Background The evidence base for quality improvement (QI) interventions is expanding rapidly. The diversity of the initiatives and the inconsistency in labeling these as QI interventions makes it challenging for researchers, policymakers, and QI practitioners to access the literature systematically and to identify relevant publications. Methods We evaluated search strategies developed for MEDLINE (Ovid) and PubMed based on free text words, Medical subject headings (MeSH), QI intervention components, continuous quality improvement (CQI) methods, and combinations of the strategies. Three sets of pertinent QI intervention publications were used for validation. Two independent expert reviewers screened publications for relevance. We compared the yield, recall rate, and precision of the search strategies for the identification of QI publications and for a subset of empirical studies on effects of QI interventions. Results The search yields ranged from 2,221 to 216,167 publications. Mean recall rates for reference publications ranged from 5% to 53% for strategies with yields of 50,000 publications or fewer. The 'best case' strategy, a simple text word search with high face validity ('quality' AND 'improv*' AND 'intervention*') identified 44%, 24%, and 62% of influential intervention articles selected by Agency for Healthcare Research and Quality (AHRQ) experts, a set of exemplar articles provided by members of the Standards for Quality Improvement Reporting Excellence (SQUIRE) group, and a sample from the Cochrane Effective Practice and Organization of Care Group (EPOC) register of studies, respectively. We applied the search strategy to a PubMed search for articles published in 10 pertinent journals in a three-year period which retrieved 183 publications. Among these, 67% were deemed relevant to QI by at least one of two independent raters. Forty percent were classified as empirical studies reporting on a QI intervention. Conclusions The presented search terms and operating characteristics can be used to guide the identification of QI intervention publications. Even with extensive iterative development, we achieved only moderate recall rates of reference publications. Consensus development on QI reporting and initiatives to develop QI-relevant MeSH terms are urgently needed

    Ultrafast transmission electron microscopy using a laser-driven field emitter: Femtosecond resolution with a high coherence electron beam

    Get PDF
    We present the development of the first ultrafast transmission electron microscope (UTEM) driven by localized photoemission from a field emitter cathode. We describe the implementation of the instrument, the photoemitter concept and the quantitative electron beam parameters achieved. Establishing a new source for ultrafast TEM, the Göttingen UTEM employs nano-localized linear photoemission from a Schottky emitter, which enables operation with freely tunable temporal structure, from continuous wave to femtosecond pulsed mode. Using this emission mechanism, we achieve record pulse properties in ultrafast electron microscopy of 9 Å focused beam diameter, 200 fs pulse duration and 0.6 eV energy width. We illustrate the possibility to conduct ultrafast imaging, diffraction, holography and spectroscopy with this instrument and also discuss opportunities to harness quantum coherent interactions between intense laser fields and free-electron beams
    • …
    corecore