16 research outputs found

    Reducing the False-Positive Rate for Isovalerylcarnitine in Expanded Newborn Screening: The Application of a Second-Tier Test

    Get PDF
    Abstract The isodecyl neopentanoate is an ingredient used in the cosmetic industry to prepare a nipple fissure balm. We report on 12 newborns that showed elevated C5-acylcarnitine levels upon newborn screening following treatment with balm. The first 3 neonates were immediately recalled for confirmatory tests and resulted negative for both isovaleric acidemia and short/branched chain acyl-CoA dehydrogenase deficiency. In the other 9 cases, the immediate recall was avoided by applying a new second-tier test able to confirm the presence of pivaloylcarnitine. The concentration of C5-acylcarnitine was measured in the days following the suspension of balm application. Abnormal concentrations of C5-acylcarnitine did not seem to be associated with free carnitine deficiency, probably due to the short time of exposure. A direct correlation between balm ingestion and the elevation in pivaloylcarnitine has been demonstrated in 10 adult volunteers. The commercial balm containing a pivalic acid derivative is causal of false-positive results during newborn screening, and it could have the potential to cause secondary carnitine deficiency when used chronically

    Development of Strategies to Decrease False Positive Results in Newborn Screening

    No full text
    The expansion of national newborn screening (NBS) programmes has provided significant benefits in the diagnosis and early treatment of several rare, heritable conditions, preventing adverse health outcomes for most affected infants. New technological developments have enabled the implementation of testing panel covering over 50 disorders. Consequently, the increment of false positive rate has led to a high number of healthy infants recalled for expensive and often invasive additional testing, opening a debate about the harm-benefit ratio of the expanded newborn screening. The false-positive rate represents a challenge for healthcare providers working in NBS systems. Here, we give an overview on the most commonly used strategies for decreasing the adverse effects due to inconclusive screening results. The focus is on NBS performance improvement through the implementation of analytical methods, the application of new and more informative biomarkers, and by using post-analytical interpretive tools. These strategies, used as part of the NBS process, can to enhance the positive predictive value of the test and reduce the parental anxiety and healthcare costs related to the unnecessary tests and procedures

    Heptadecanoylcarnitine (C17) a novel candidate biomarker for newborn screening of propionic and methylmalonic acidemias

    No full text
    BACKGROUND: 3-Hydroxypalmitoleoyl-carnitine (C16:1-OH) has recently been reported to be elevated in acylcarnitine profiles of patients with propionic acidemia (PA) or methylmalonic acidemia (MMA) during expanded newborn screening (NBS). High levels of C16:1-OH, combined with other hydroxylated long chain acylcarnitines are related to long-chain 3-hydroxyacyl-CoA dehydrogenase deficiency (LCHADD) and trifunctional protein (TFP) deficiency. METHODS: The acylcarnitine profile of two LCHADD patients was evaluated using liquid chromatography-tandem mass spectrometric method. A specific retention time was determined for each hydroxylated long chain acylcarnitine. The same method was applied to some neonatal dried blood spots (DBSs) from PA and MMA patients presenting abnormal C16:1-OH concentrations. RESULTS: The retention time of the peak corresponding to C16:1-OH in LCHADD patients differed from those in MMA and PA patients. Heptadecanoylcarnitine (C17) has been identified as the novel biomarker specific for PA and MMA patients through high resolution mass spectrometry (Orbitrap) experiments. We found that 21 out of 23 neonates (22 MMA, and 1PA) diagnosed through the Tuscany region NBS program exhibited significantly higher levels of C17 compared to controls. Twenty-three maternal deficiency (21 vitamin B12 deficiency, 1 homocystinuria and 1 gastrin deficiency) samples and 82 false positive for elevated propionylcarnitine (C3) were also analyzed. CONCLUSIONS: We have characterized a novel biomarker able to detect propionate disorders during expanded newborn screening (NBS). The use of this new biomarker may improve the analytical performances of NBS programs especially in laboratories where second tier tests are not performed

    Tandem mass spectrometry, but not T-cell receptor excision circle analysis, identifies newborns with late-onset adenosine deaminase deficiency

    No full text
    Background: Adenosine deaminase (ADA)-severe combined immunodeficiency (SCID) is caused by genetic variants that disrupt the function of ADA. In its early-onset form, it is rapidly fatal to infants. Delayed or late-onset ADA-SCID is characterized by insidious progressive immunodeficiency that leads to permanent organ damage or death. Quantification of T-cell receptor excision circles (TRECs) or tandem mass spectrometry (tandem-MS) analysis of dried blood spots (DBSs) collected at birth can identify newborns with early-onset ADA-SCID and are used in screening programs. However, it is not clear whether these analyses can identify newborns who will have delayed or late-onset ADA-SCID before symptoms appear. Objective: We performed a retrospective study to evaluate whether tandem-MS and quantitative TREC analyses of DBSs could identify newborns who had delayed-onset ADA-SCID later in life. Methods: We tested stored DBSs collected at birth from 3 patients with delayed-onset ADA-SCID using tandem-MS (PCT EP2010/070517) to evaluate levels of adenosine and 2'-deoxyadenosine and real-time PCR to quantify TREC levels. We also analyzed DBSs from 3 newborns with early-onset ADA-SCID and 2 healthy newborn carriers of ADA deficiency. Results: The DBSs taken at birth from the 3 patients with delayed-onset ADA-SCID had adenosine levels of 10, 25, and 19 mu mol/L (normal value, <1.5 mu mol/L) and 2'-deoxyadenosine levels of 0.7, 2.7, and 2.4 mu mol/L (normal value, <0.07 mu mol/L); the mean levels of adenosine and 2'-deoxyadenosine were respectively 12.0- and 27.6-fold higher than normal values. DBSs taken at birth from all 3 patients with delayed-onset ADA deficiency had normal TREC levels, but TRECs were undetectable in blood samples taken from the same patients at the time of diagnosis. Conclusion: Tandem-MS but not TREC quantification identifies newborns with delayed-or late-onset ADA deficiency
    corecore