201 research outputs found

    Journal Staff

    Get PDF
    There are fewer longitudinal studies from China on symptoms as described for the sick building syndrome (SBS). Here, we performed a two-year prospective study and investigated associations between environmental parameters such as room temperature, relative air humidity (RH), carbon dioxide (CO2), nitrogen dioxide (NO2), sulphur dioxide (SO2), ozone (O-3), particulate matter (PM10), and health outcomes including prevalence, incidence and remission of SBS symptoms in junior high schools in Taiyuan, China. Totally 2134 pupils participated at baseline, and 1325 stayed in the same classrooms during the study period (2010-2012). The prevalence of mucosal symptoms, general symptoms and symptoms improved when away from school (school-related symptoms) was 22.7%, 20.4% and 39.2%, respectively, at baseline, and the prevalence increased during follow-up (P<0.001). At baseline, both indoor and outdoor SO2 were found positively associated with prevalence of school-related symptoms. Indoor O-3 was shown to be positively associated with prevalence of skin symptoms. At follow-up, indoor PM10 was found to be positively associated with new onset of skin, mucosal and general symptoms. CO2 and RH were positively associated with new onset of mucosal, general and school-related symptoms. Outdoor SO2 was positively associated with new onset of skin symptoms, while outdoor NO2 was positively associated with new onset of skin, general and mucosal symptoms. Outdoor PM10 was found to be positively associated with new onset of skin, general and mucosal symptoms as well as school-related symptoms. In conclusion, symptoms as described for SBS were commonly found in school children in Taiyuan City, China, and increased during the two-year follow-up period. Environmental pollution, including PM10, SO2 and NO2, could increase the prevalence and incidence of SBS and decrease the remission rate. Moreover, parental asthma and allergy (heredity) and pollen or pet allergy (atopy) can be risk factors for SBS

    Acute Effects of a Fungal Volatile Compound

    Get PDF
    Objective: 3-Methylfuran (3-MF) is a common fungal volatile product with active biologic properties, and previous studies have indicated a contribution to airway disease. The aim of the present study was to assess the acute health effects of this compound in humans. Design: Acute effects were assessed via chamber exposure to (1 mg/m(3)) 3-MF. Participants and measurements: Twenty-nine volunteers provided symptom reports, ocular electromyograms, measurement of eye tear film break-up time, vital staining of the eye, nasal lavage, acoustic rhinometry, transfer tests, and dynamic spirometry. Results: No subjective ratings were significantly increased during exposure. Blinking frequency and the lavage biomarkers myeloperoxidase and lysozyme were significantly increased, and forced vital capacity was significantly decreased during exposure to 3-MF compared with air control. Conclusions and relevance to clinical practice: Acute effects in the eyes, nose, and airways were detected and might be the result of the biologically active properties of 3-MF. Thus, 3-MF may contribute to building-related illness

    Exploring the role of indoor microbiome and environmental characteristics in rhinitis symptoms among university students

    Get PDF
    IntroductionRhinitis is one of the most prevalent chronic respiratory diseases worldwide. There is emerging evidence suggesting that the indoor microbiome may contribute the onset and exacerbation of rhinitis symptoms, but comprehensive studies on this topic remain scarce.MethodsIn this study, we assessed the microbiome assemblage of settled air dust collected in Petri dishes in 86 dormitory rooms of Shanxi University, China using 16s rRNA sequencing. A self-administered questionnaire, including questions about rhinitis symptoms and personal information, was completed by 357 students residing in these dormitories. Logistic and linear regression model was applied to examine the associations between environmental characteristics, indoor microbiome, and rhinitis.ResultsThe most abundant genera in the dormitories were Ralstonia (15.6%), Pelomonas (11.3%), Anoxybacillus (9.3%) and Ochrobactrum (6.2%). Taxa richness in the class of Actinobacteria and Fusobacteriia was negatively/protectively associated with rhinitis (p<0.05). Six bacterial genera, including those from Actinobacteria (Actinomyces), Fusobacteriia (Fusobacterium), and Bacteroidetes (Prevotella and Capnocytophaga), were negatively/protectively associated with rhinitis. Conversely, seven genera, predominantly from Alphaproteobacteria and Betaproteobacteria (Sphingomonas, Caulobacter, uncharacterized Caulobacteraceae and Comamonadaceae), were positively associated with rhinitis. Living in higher floor level and higher indoor PM2.5 concentrations were associated with a higher abundance of taxa potentially protective against rhinitis and a lower abundance of taxa potentially increasing the risk of rhinitis (P<0.01). However, having curtain indoor and higher indoor CO2 concentrations were associated with a lower abundance of taxa potentially protective against rhinitis and a higher abundance of taxa potentially increasing the risk of rhinitis (P<0.01).DiscussionThis study enhances our understanding of the complex interactions between environmental characteristics, indoor microbiomes, and rhinitis, shedding light on potential strategies to manipulate indoor microbiome for disease prevention and control

    Respiratory health among office workers in Malaysia and endotoxin and (1,3)-b-glucan in office dust

    Get PDF
    Objective: To examine the associations between endotoxin and (1,3)-β-glucan concentrations in office dust and respiratory symptoms and airway inflammation among 695 office workers in Malaysia. Methods: Health data were collected using a questionnaire, sensitisation testing and measurement of fractional exhaled nitric oxide (FeNO). Indoor temperature, relative air humidity (RH) and carbon dioxide (CO 2) were measured in the offices and settled dust was vacuumed and analysed for endotoxin and (1,3)-β-glucan concentrations. Associations were analysed by two level multiple logistic regression. Results: Overall, 9.6% of the workers had doctor-diagnosed asthma, 15.5% had wheeze, 18.4% had daytime attacks of breathlessness and 25.8% had elevated FeNO (≥25 ppb). The median levels in office dust were 11.3 EU/mg endotoxin and 62.9 ng/g (1,3)-β-glucan. After adjusting for personal and home environment factors, endotoxin concentration in dust was associated with wheeze (P = 0.02) and rhino conjunctivitis (P = 0.007). The amount of surface dust (P = 0.04) and (1,3)-β-glucan concentration dust (P = 0.03) were associated with elevated FeNO. Conclusion: Endotoxin in office dust could be a risk factor for wheeze and rhino conjunctivitis among office workers in mechanically ventilated offices in a tropical country. The amount of dust and (1,3)-β-glucan (a marker of indoor mould exposure) were associated with Th2 driven airway inflammation

    Universiti Putra Malaysia, 43400 UPM Serdang, Selangor, Malaysia f Environmental Health, Allied Health Science College Sg Buloh, Ministry of Health Malaysia

    Get PDF
    • Elevated FeNO, a marker of lower airway inflammation, was found in many students. • Signs of dampness in the classroom were related to airway infections among students. • Students in classrooms with signs of dampness had 31% higher FeNO values. • Higher quantities of DNA from Aspergillus versicolor were related to higher FeNO. • DNA from Aspergillus versicolor were related to asthma and respiratory symptoms. Few health studies exist on dampness and mould in schools in the tropics. We studied associations between fraction of exhaled nitric oxide (FeNO), respiratory symptoms and airway infections among students and dampness and fungal DNA in schools in Malaysia. A total of 368 randomly selected students from 32 classrooms in 8 secondary schools in Penang, Malaysia, participated (58% participation rate). Information on current respiratory symptoms and the home environment was collected by a standardised questionnaire. FeNO was measured by NIOX MINO (50 ml/min). The classrooms were inspected and dust was collected by vacuuming on special filters and was analysed for five fungal DNA sequences by quantitative PCR. Linear mixed models and 3-level multiple logistic regression (school, classroom, student) were applied adjusting for demographic data and the home environment. Totally 10.3% reported doctor's diagnosed asthma, 15.1% current wheeze, 12.4% current asthma, 37.3% daytime breathlessness, 10.2% nocturnal breathlessness, 38.9% airway infections and 15.5% had pollen or furry G R A P H I C A L A B S T R A C T a b s t r a c t a r t i c l e i n f o Contents lists available at ScienceDirect Science of the Total Environment j o u r n a l h o m e p a g e : w w w . e l s e v i e r . c o m / l o c a t e / s c i t o t e n v pet allergy. The geometric mean of FeNO was 19.9 ppb and 45% had elevated FeNO (N20 ppb). Boys had higher levels of FeNO. Chinese had less daytime breathlessness than Malay (OR = 0.30: p b 0.001). Indoor carbon dioxide levels were low (380-720 ppm). Dampness was observed in 18% of the classrooms and was associated with respiratory infections (OR = 3.70; 95% CI 1.14-12.1) and FeNO (p = 0.04). Aspergillus versicolor DNA was detected in 67% of the classrooms. Higher numbers of Aspergillus versicolor DNA in classroom dust were associated with wheeze (p = 0.006), current asthma (p = 0.002), respiratory infections (p = 0.005) and elevated FeNO levels (p = 0.02). In conclusion, respiratory symptoms were common among the students and the high FeNO levels indicate ongoing airway inflammation. Building dampness and the mould Aspergillus versicolor in schools in Malaysia can be risk factors for impaired respiratory health among the students

    Comparison of Oxidative Properties, Light Absorbance, and Total and Elemental Mass Concentration of Ambient PM(2.5) Collected at 20 European Sites

    Get PDF
    OBJECTIVE: It has been proposed that the redox activity of particles may represent a major determinant of their toxicity. We measured the in vitro ability of ambient fine particles [particulate matter with aerodynamic diameters ≤2.5 μm (PM(2.5))] to form hydroxyl radicals ((•)OH) in an oxidant environment, as well as to deplete physiologic antioxidants (ascorbic acid, glutathione) in the naturally reducing environment of the respiratory tract lining fluid (RTLF). The objective was to examine how these toxicologically relevant measures were related to other PM characteristics, such as total and elemental mass concentration and light absorbance. DESIGN: Gravimetric PM(2.5) samples (n = 716) collected over 1 year from 20 centers participating in the European Community Respiratory Health Survey were available. Light absorbance of these filters was measured with reflectometry. PM suspensions were recovered from filters by vortexing and sonication before dilution to a standard concentration. The oxidative activity of these particle suspensions was then assessed by measuring their ability to generate (•)OH in the presence of hydrogen peroxide, using electron spin resonance and 5,5-dimethyl-1-pyrroline-N-oxide as spin trap, or by establishing their capacity to deplete antioxidants from a synthetic model of the RTLF. RESULTS AND CONCLUSION: PM oxidative activity varied significantly among European sampling sites. Correlations between oxidative activity and all other characteristics of PM were low, both within centers (temporal correlation) and across communities (annual mean). Thus, no single surrogate measure of PM redox activity could be identified. Because these novel measures are suggested to reflect crucial biologic mechanisms of PM, their use may be pertinent in epidemiologic studies. Therefore, it is important to define the appropriate methods to determine oxidative activity of PM

    Respiratory Health among Korean Pupils in Relation to Home, School and Outdoor Environment

    Get PDF
    There are few studies about school-environment in relation to pupils' respiratory health, and Korean school-environment has not been characterized. All pupils in 4th grade in 12 selected schools in three urban cities in Korea received a questionnaire (n = 2,453), 96% participated. Gaseous pollutants and ultrafine particles (UFPs) were measured indoors (n = 34) and outdoors (n = 12) during winter, 2004. Indoor dampness at home was investigated by the questionnaire. To evaluate associations between respiratory health and environment, multiple logistic- and multi-level regression models were applied adjusting for potential confounders. The mean age of pupils was 10 yr and 49% were boys. No school had mechanical ventilation and CO2-levels exceeded 1,000 ppm in all except one of the classrooms. The indoor mean concentrations of SO2, NO2, O3 and formaldehyde were 0.6 µg/m3, 19 µg/m3, 8 µg/m3 and 28 µg/m3, respectively. The average level of UFPs was 18,230 pt/cm3 in the classrooms and 16,480 pt/cm3 outdoors. There were positive associations between wheeze and outdoor NO2, and between current asthma and outdoor UFPs. With dampness at home, pupils had more wheeze. In conclusion, outdoor UFPs and even low levels of NO2 may adversely contribute to respiratory health in children. High CO2-levels in classrooms and indoor dampness/mold at home should be reduced
    corecore