28 research outputs found

    Cultural and linguistic testing of the Handling Questionnaire: a specific instrument for assessing the patient’s acceptability of dry powder inhalers

    Get PDF
    The testing and checking phases of a questionnaire are briefly described in this paper, identifying the common errors due to incorrect formulation of questions and the main issues. The theoretical methods for “testing” a questionnaire has been examined in the first section, in the second section the testing process for a specific questionnaire for assessing the patient’s acceptability of a dry powder device (the Handling Questionnaire) has been described, together with the grading of improvement achieved

    Use of aerosols in bronchiectasis patients

    Get PDF
    Bronchiectasis is a chronic respiratory disease which recognises different etiologies, and characterised by persistent cough, bronchial hypersecretion, airway colonisation with Gram-negative pathogens; frequent infectious exacerbations; progressive lung function decline, and poor quality of life. Several therapeutic strategies are used for managing bronchiectasis, and nebulised medications are regarded with great and ever increasing interest because they allow the direct medication of targets airway structures, higher concentrations of the drug employed, and much less systemic effects. In general terms, the available therapeutic strategies lead to different results depending of whether bronchiectasis are related to cystic fibrosis or not. The effects of the main classes of drugs for aerosol delivery in bronchiectasis patients have been reviewed and updated. Further research is needed in order to ameliorate therapeutic interventions in bronchiectasis, both in terms of new molecules and aerosol formulations to use, and of systems able to optimize drug delivery and drug effectiveness

    Costs of chronic obstructive pulmonary disease (COPD) in Italy: The SIRIO study (Social Impact of Respiratory Integrated Outcomes)

    Get PDF
    SummaryChronic respiratory diseases affect a large number of subjects in Italy and are characterized by high socio-health costs. The aim of the Social Impact of Respiratory Integrated Outcomes (SIRIO) study was to measure the health resources consumption and costs generated in 1 year by a population of patients with chronic obstructive pulmonary disease (COPD) in a real-life setting. This bottom-up, observational, prospective, multicentric study was based on the collection of demographic, clinical, diagnostic, therapeutic and outcome data from COPD patients who reported spontaneously to pneumological centers participating in the study, the corresponding economic outcomes being assessed at baseline and after a 1-year survey. A total of 748 COPD patients were enrolled, of whom 561 [408m, mean age 70.3 years (SD 9.2)] were defined as eligible by the Steering Committee. At the baseline visit, the severity of COPD (graded according to GOLD 2001 guidelines) was 24.2% mild COPD, 53.7% moderate and 16.8% severe. In the 12 months prior to enrollment, 63.8% visited a general practitioner (GP); 76.8% also consulted a national health service (NHS) specialist; 22.3% utilized Emergency Care and 33% were admitted to hospital, with a total of 5703 work days lost. At the end of the 1-year survey, the severity of COPD changed as follows: 27.5% mild COPD, 47.4% moderate and 19.4% severe. Requirement of health services dropped significantly: 57.4% visited the GP; 58.3% consulted an NHS specialist; 12.5% used Emergency Care and 18.4% were hospitalized. Compared to baseline, the mean total cost per patient decreased by 21.7% (p<0.002). In conclusion, a significant reduction in the use of health resources and thus of COPD-related costs (both direct and indirect costs) was observed during the study, likely due to a more appropriate care and management of COPD patients

    Essential amino acid supplementation in patients with severe COPD: a step towards home rehabilitation

    Get PDF
    Background. Pulmonary Rehabilitation ("Rehabilitation") can improve both lung function and quality of life in patients suffering from chronic obstructive pulmonary disease (COPD) even if only a very small proportion of patients have access to Rehabilitation. Supplementation of Essential Amino Acids (EAAs) might allow COPD patients to achieve some typical Rehabilitation outcomes such as a better physical performance and an improved health status. Methods. 88 COPD out-patients (GOLD class 3-4) with a body mass index (BMI) &lt;23 Kg/m2 were randomised to receive EAAs (n=44) or placebo (n=44) for twelve weeks. Primary outcome measures were changes in both physical activities in daily life (measured by Sense Wear Armband in terms of mean steps walked in one week) and in quality of life (measured by the St George's Respiratory Questionnaire, SGRQ). Results. After 12 weeks, the physical performance was significantly increased vs baseline only in patients who received EAAs (1140.33 ± 524.69 and 638.68 ± 662.1 steps/day, respectively; p=0.02), being also the comparison vs the placebo group highly significant (p=0.003). Similarly, the SGRQ score improved significantly only in EAA patients (69.35 ± 9.51 vs baseline 72.04 ± 8.62; p&lt;0.01), and changes were significantly different from those measured in the placebo group (p&lt;0.001). Furthermore, when compared to those who received placebo, EAAs patients significantly increased their fat-free mass (p=0.04), muscle strength (p&lt;0.01), saturation of oxygen (p=0.05), serum albumin (p&lt;0.001), and also ameliorated their original cognitive dysfunction (p=0.02). Conclusions. Oral supplementation with EAAs contribute to improve the daily-life performance in domiciliary severe COPD patients who can not enter any Rehabilitation programme, together with their quality of life; nutritional and cognitive status, and muscle strength

    Brittle asthma

    Get PDF
    Brittle asthma is a clinical phenotype of the disease at the severe end of the spectrum. Type 1 brittle asthma is characterised by a maintained wide PEF variability (> 40% diurnal variation for > 50% of the time over a period of at least 150 days) despite considerable medical therapy including a dose of inhaled steroids of at least 1500 ÎŒg of beclomethasone or equivalent. Type 2 brittle asthma is characterised by sudden acute attacks occurring in less than three hours without an obvious trigger on a background of apparent normal airway function or well controlled asthma. Mechanisms behind the development of brittle asthma include smooth muscle contraction and edema of the airways, which are supported by chronic airway inflammation. Allergy reactions, impairment of local immunity, respiratory infections, psycho-social disorders and reduced perception of worsening airway function are the risk factors for brittle asthma. The diagnosis is based on the analysis of specific symptoms, role of triggers, personal or family history, measurement of lung function and PEF monitoring. Pharmacological treatment of type 1 brittle asthma in addition to the high doses of inhaled and/or oral steroids and bronchodilators includes subcutaneous injections of ÎČ2 agonist and inhalation of long acting ÎČ2 agonist. The treatment of patients with type 2 brittle asthma includes exclusion of allergen exposure, identification of triggers, self management and management of acute attacks

    PIKO-1, an effective, handy device for the patient’s personal PEFR and FEV1 electronic long-term monitoring

    Get PDF
    Background and Aim. Subjects with airway obstruction are strongly recommended to monitor their lung function, which is particularly variable in asthma. Unlike PEFR, other personal measurements (such as FEV1) are still difficult to perform. PIKO-1 is the first electronic device for both PEFR and FEV1 personal check, but its precision has not yet been assessed. The aim of this study was to compare PEFR and FEV1 values from PIKO-1 and from a conventional spirometer in subjects with airway obstruction. Methods. In total, 352 subjects (217 men; 47.6 ± 19.0 years; 72.6 ± 15.0 kg; 168.1 ± 11.9 cm) performed sequential measurements using a PIKO-1 device and a spirometer. Wilcoxon signed-rank test and sign test were used as statistical tests. Results. Mean FEV1 values from the spirometer and PIKO-1, respectively, were 2.9 L ± 1.1 and 3.0 L ± 1.1, and mean PEFR values were 466.1 L/min ± 164.5 SD and 426.3 L/min ± 151.6 SD. PIKO-1 proved to overestimate FEV1 values by 4% (p<0.0001) and to underestimate PEFR values by 8% (p<0.000) systematically. Conclusions. The precision of both PIKO-1 measurements (such as FEV1 and PEFR) have been assessed. PEFR and FEV1 measures should be reset by two different constants. Nevertheless, PIKO-1 is a suitable and reliable device for the personal monitoring of obstructive patients in real life

    Effect of erdosteine on the rate and duration of COPD exacerbations: the RESTORE study

    Get PDF
    Oxidative stress contributes to chronic obstructive pulmonary disease (COPD) exacerbations and antioxidants can decrease exacerbation rates, although we lack data about the effect of such drugs on exacerbation duration. The RESTORE (Reducing Exacerbations and Symptoms by Treatment with ORal Erdosteine in COPD) study was a prospective randomised, double-blind, placebo-controlled study, enrolling patients aged 40–80 years with Global Initiative for Chronic Obstructive Lung Disease stage II/III. Patients received erdosteine 300 mg twice daily or placebo added to usual COPD therapy for 12 months. The primary outcome was the number of acute exacerbations during the study. In the pre-specified intention-to-treat population of 445 patients (74% male; mean age 64.8 years, forced expiratory volume in 1 s 51.8% predicted) erdosteine reduced the exacerbation rate by 19.4% (0.91 versus. 1.13 exacerbations·patient−1·year−1 for erdosteine and placebo, respectively; p=0.01), due to an effect on mild events; the reduction in the rate of mild exacerbations was 57.1% (0.23 versus 0.54 exacerbations·patient−1·year−1 for erdosteine and placebo, respectively; p=0.002). No significant difference was observed in the rate of moderate and severe exacerbations (0.68 versus 0.59 exacerbations·patient−1·year−1 for erdosteine and placebo, respectively; p=0.054) despite a trend in favour of the comparison group. Erdosteine decreased the exacerbation duration irrespective of event severity by 24.6% (9.55 versus 12.63 days for erdosteine and placebo, respectively; p=0.023). Erdosteine significantly improved subject and physician subjective severity scores (p=0.022 and p=0.048, respectively), and reduced the use of reliever medication (p<0.001), but did not affect the St George's Respiratory Questionnaire score or the time to first exacerbation. In patients with COPD, erdosteine can reduce both the rate and duration of exacerbations. The percentage of patients with adverse events was similar in both the placebo and erdosteine treatment groups

    Silicon and Germanium Nanostructures for Photovoltaic Applications: Ab-Initio Results

    Get PDF
    Actually, most of the electric energy is being produced by fossil fuels and great is the search for viable alternatives. The most appealing and promising technology is photovoltaics. It will become truly mainstream when its cost will be comparable to other energy sources. One way is to significantly enhance device efficiencies, for example by increasing the number of band gaps in multijunction solar cells or by favoring charge separation in the devices. This can be done by using cells based on nanostructured semiconductors. In this paper, we will present ab-initio results of the structural, electronic and optical properties of (1) silicon and germanium nanoparticles embedded in wide band gap materials and (2) mixed silicon-germanium nanowires. We show that theory can help in understanding the microscopic processes important for devices performances. In particular, we calculated for embedded Si and Ge nanoparticles the dependence of the absorption threshold on size and oxidation, the role of crystallinity and, in some cases, the recombination rates, and we demonstrated that in the case of mixed nanowires, those with a clear interface between Si and Ge show not only a reduced quantum confinement effect but display also a natural geometrical separation between electron and hole
    corecore