683 research outputs found

    On the magnetosensitivity of lipid peroxidation: two- versus three-radical dynamics

    Get PDF
    This is the final version. Available on open access from the Royal Society of Chemistry via the DOI in this recordData availability: The datasets generated during the current study are available from the corresponding author on reasonable request.We present a theoretical analysis of the putative magnetosensitivity of lipid peroxidation. We focus on the widely accepted radical pair mechanism (RPM) and a recently suggested idea based on spin dynamics induced in three-radical systems by the mutual electron–electron dipolar coupling (D3M). We show that, contrary to claims in the literature, lipid peroxides, the dominant chain carriers of the autoxidation process, have associated non-zero hyperfine coupling interactions. This suggests that their recombination could, in principle, be magnetosensitive due to the RPM. While the RPM indeed goes a long way to explaining magnetosensitivity in these systems, we show that the simultaneous interaction of three peroxyl radicals via the D3M can achieve larger magnetic field effects (MFE), even if the third radical is remote from the recombining radical pair. For randomly oriented three-radical systems, the D3M induces a low-field effect comparable to that of the RPM. The mechanism furthermore immunizes the spin dynamics to the presence of large exchange coupling interactions in the recombining radical pair, thereby permitting much larger MFE at magnetic field intensities comparable to the geomagnetic field than would be expected for the RPM. Based on these characteristics, we suggest that the D3M could be particularly relevant for MFE at low fields, provided that the local radical concentration is sufficient to allow for three-spin radical correlations. Eventually, our observations suggest that MFEs could intricately depend on radical concentration and larger effects could ensue under conditions of oxidative stress.Engineering and Physical Sciences Research Council (EPSRC

    LWIR Snapshot Imaging Polarimeter

    Get PDF
    This report describes the results of a phase 1 STTR to design a longwave infrared imaging polarimeter. The system design, expected performance and components needed to construct the imaging polarimeter are described. Expected performance is modeled and sytem specifications are presented

    Middle School Single-Gender Science Classes: Self-Concept and Discourse Analysis

    Get PDF
    One southwestern, suburban middle school in the United States implemented a voluntary, single-gender science program. Although other studies have documented the effects of single-gender instruction and recent educational innovations have focused on its benefits, minimal current research has investigated the effects in middle school science classroom contexts. This study indicated that the patterns of discourse differed between single-gender and mixed-gender classes, with single-gender male classes participating in higher levels of discourse than females in middle school single-gender classes. Overall, the self-concept for females was low in science and school performance. The discourse analysis revealed that males and females used higher level utterances when placed in single-gender classrooms

    How symmetry-breaking can amplify the magnetosensitivity of dipolarly coupled n-radical systems

    Get PDF
    This is the final version. Available on open access from AIP Publishing via the DOI in this recordData availability: The data that support the findings of this study are available from the corresponding author upon reasonable request.In systems of more than two reactive radicals, the radical recombination probability can be magnetosensitive due to the mere effect of the inter-radical electron-electron dipolar coupling. Here, we demonstrate that this principle, previously established for three-radical systems, generalizes to n-radical systems. We focus on radical systems in the plane and explore the effects of symmetry, in particular its absence, on the associated magnetic field effects of the recombination yield. We show, by considering regular configurations and slightly distorted geometries, that the breaking of geometric symmetry can lead to an enhancement of the magnetosensitivity of these structures. Furthermore, we demonstrate the presence of effects at low-field that are abolished in the highly symmetric case. This could be important to the understanding of the behavior of radicals in biological environments in the presence of weak magnetic fields comparable to the Earth's, as well as the construction of high-precision quantum sensing devices.Engineering and Physical Sciences Research Council (EPSRC

    A Relational Event Approach to Modeling Behavioral Dynamics

    Full text link
    This chapter provides an introduction to the analysis of relational event data (i.e., actions, interactions, or other events involving multiple actors that occur over time) within the R/statnet platform. We begin by reviewing the basics of relational event modeling, with an emphasis on models with piecewise constant hazards. We then discuss estimation for dyadic and more general relational event models using the relevent package, with an emphasis on hands-on applications of the methods and interpretation of results. Statnet is a collection of packages for the R statistical computing system that supports the representation, manipulation, visualization, modeling, simulation, and analysis of relational data. Statnet packages are contributed by a team of volunteer developers, and are made freely available under the GNU Public License. These packages are written for the R statistical computing environment, and can be used with any computing platform that supports R (including Windows, Linux, and Mac).

    Pain assessment for people with dementia: a systematic review of systematic reviews of pain assessment tools.

    Get PDF
    BACKGROUND: There is evidence of under-detection and poor management of pain in patients with dementia, in both long-term and acute care. Accurate assessment of pain in people with dementia is challenging and pain assessment tools have received considerable attention over the years, with an increasing number of tools made available. Systematic reviews on the evidence of their validity and utility mostly compare different sets of tools. This review of systematic reviews analyses and summarises evidence concerning the psychometric properties and clinical utility of pain assessment tools in adults with dementia or cognitive impairment. METHODS: We searched for systematic reviews of pain assessment tools providing evidence of reliability, validity and clinical utility. Two reviewers independently assessed each review and extracted data from them, with a third reviewer mediating when consensus was not reached. Analysis of the data was carried out collaboratively. The reviews were synthesised using a narrative synthesis approach. RESULTS: We retrieved 441 potentially eligible reviews, 23 met the criteria for inclusion and 8 provided data for extraction. Each review evaluated between 8 and 13 tools, in aggregate providing evidence on a total of 28 tools. The quality of the reviews varied and the reporting often lacked sufficient methodological detail for quality assessment. The 28 tools appear to have been studied in a variety of settings and with varied types of patients. The reviews identified several methodological limitations across the original studies. The lack of a 'gold standard' significantly hinders the evaluation of tools' validity. Most importantly, the samples were small providing limited evidence for use of any of the tools across settings or populations. CONCLUSIONS: There are a considerable number of pain assessment tools available for use with the elderly cognitive impaired population. However there is limited evidence about their reliability, validity and clinical utility. On the basis of this review no one tool can be recommended given the existing evidence

    Systematic review and meta-analysis of the diagnostic accuracy of ultrasonography for deep vein thrombosis

    Get PDF
    Background Ultrasound (US) has largely replaced contrast venography as the definitive diagnostic test for deep vein thrombosis (DVT). We aimed to derive a definitive estimate of the diagnostic accuracy of US for clinically suspected DVT and identify study-level factors that might predict accuracy. Methods We undertook a systematic review, meta-analysis and meta-regression of diagnostic cohort studies that compared US to contrast venography in patients with suspected DVT. We searched Medline, EMBASE, CINAHL, Web of Science, Cochrane Database of Systematic Reviews, Cochrane Controlled Trials Register, Database of Reviews of Effectiveness, the ACP Journal Club, and citation lists (1966 to April 2004). Random effects meta-analysis was used to derive pooled estimates of sensitivity and specificity. Random effects meta-regression was used to identify study-level covariates that predicted diagnostic performance. Results We identified 100 cohorts comparing US to venography in patients with suspected DVT. Overall sensitivity for proximal DVT (95% confidence interval) was 94.2% (93.2 to 95.0), for distal DVT was 63.5% (59.8 to 67.0), and specificity was 93.8% (93.1 to 94.4). Duplex US had pooled sensitivity of 96.5% (95.1 to 97.6) for proximal DVT, 71.2% (64.6 to 77.2) for distal DVT and specificity of 94.0% (92.8 to 95.1). Triplex US had pooled sensitivity of 96.4% (94.4 to 97.1%) for proximal DVT, 75.2% (67.7 to 81.6) for distal DVT and specificity of 94.3% (92.5 to 95.8). Compression US alone had pooled sensitivity of 93.8 % (92.0 to 95.3%) for proximal DVT, 56.8% (49.0 to 66.4) for distal DVT and specificity of 97.8% (97.0 to 98.4). Sensitivity was higher in more recently published studies and in cohorts with higher prevalence of DVT and more proximal DVT, and was lower in cohorts that reported interpretation by a radiologist. Specificity was higher in cohorts that excluded patients with previous DVT. No studies were identified that compared repeat US to venography in all patients. Repeat US appears to have a positive yield of 1.3%, with 89% of these being confirmed by venography. Conclusion Combined colour-doppler US techniques have optimal sensitivity, while compression US has optimal specificity for DVT. However, all estimates are subject to substantial unexplained heterogeneity. The role of repeat scanning is very uncertain and based upon limited data

    Metachronic malignant transformation of small bowel and rectal endometriosis in the same patient

    Get PDF
    BACKGROUND: Malignant transformation of intestinal endometriosis is a rare event with an unknown rate of incidence. Metachronous progression of endometriosis to adenocarcinoma from two distant intestinal foci happening in the same patient has not been previously reported. CASE PRESENTATION: We describe a case of metachronic transformation of ileal and rectal endometriosis into an adenocarcinoma occurring in a 45-year-old female without macroscopic pelvic involvement of her endometriosis. First, a right colectomy was performed due to intestinal obstruction by an ileal mass. Pathological examination revealed an ileal endometrioid adenocarcinoma and contiguous microscopic endometriotic foci. Twenty months later, a rectal mass was discovered. An endoscopic biopsy revealed an adenocarcinoma. En bloc anterior rectum resection, hysterectomy and bilateral salpingectomy were performed. A second endometrioid adenocarcinoma arising from a focus of endometriosis within the wall of the rectum was diagnosed. CONCLUSION: Intestinal endometriosis should be considered a premalignant condition in premenopausal women
    corecore