360 research outputs found

    The influence of void size on the micropolar constitutive properties of model heterogeneous materials

    Get PDF
    In this paper the mechanical behaviour of model heterogeneous materials consisting of regular periodic arrays of circular voids within a polymeric matrix is investigated. Circular ring samples of the materials were fabricated by machining the voids into commercially available polymer sheet. Ring samples of differing sizes but similar geometries were loaded using mechanical testing equipment. Sample stiffness was found to depend on sample size with stiffness increasing as size reduced. The periodic nature of the void arrays also facilitated detailed finite element analysis of each sample. The results obtained by analysis substantiate the observed dependence of stiffness on size. Classical elasticity theory does not acknowledge this size effect but more generalized elasticity theories do predict it. Micropolar elasticity theory has therefore been used to interpret the sample stiffness data and identify constitutive properties. Modulus values for the model materials have been quantified. Values of two additional constitutive properties, the characteristic length and the coupling number, which are present within micropolar elasticity but absent from its classic counterpart have also been determined. The dependence of these additional properties on void size has been investigated and characteristic length values compared to the length scales inherent within the structure of the model materials

    A measurement of lifetime differences in the neutral D-meson system

    Full text link
    Using a high statistics sample of photoproduced charm particles from the FOCUS experiment at Fermilab, we compare the lifetimes of neutral D mesons decaying via D0 to K- pi+ and K- K+ to measure the lifetime differences between CP even and CP odd final states. These measurements bear on the phenomenology of D0 - D0bar mixing. If the D0 to K-pi+ is an equal mixture of CP even and CP odd eigenstates, we measure yCP = 0.0342 \pm 0.0139 \pm 0.0074.Comment: 15 pages, 5 figure

    Faixas normais de nutrientes em cana-de-açúcar pelos métodos ChM, DRIS e CND e nível crítico pela distribuição normal reduzida

    Get PDF
    Existem diversos métodos para a interpretação da diagnose foliar; o nível crítico ou as faixas de suficiência descritas na literatura são os mais utilizados. Porém, o uso de métodos de determinação de faixas normais de nutrientes que contemplam regiões específicas (localidades) aumenta a eficiência da interpretação. O objetivo deste trabalho foi determinar as faixas normais de nutrientes para a cultura da cana-de-açúcar, mediante a utilização dos métodos Chance Matemática (ChM), Sistema Integrado de Diagnose e Recomendação (DRIS) e Diagnose da Composição Nutricional (CND), além do Nível Crítico determinado pelo método de distribuição normal reduzida. O trabalho foi realizado tomando-se como base dados relativos a teores de nutrientes em amostras foliares e de produtividade de lavouras comerciais de cana-de-açúcar, localizadas no município de Campos de Goytacazes, RJ. Com o método da ChM, foram obtidas faixas de suficiência semelhantes aos métodos DRIS e CND, para N, Ca, S e Mn, enquanto para P, K, Mg, Cu e Zn os valores obtidos pela ChM foram superiores. A utilização dos métodos ChM, DRIS e CND, em lavouras comerciais de cana-de-açúcar em geral, possibilitou a obtenção de menor amplitude da faixa normal dos nutrientes, em comparação com os valores alcançados pelos métodos nível crítico e faixa de suficiência
    corecore