703 research outputs found

    Photoswitchable diacylglycerols enable optical control of protein kinase C.

    Get PDF
    Increased levels of the second messenger lipid diacylglycerol (DAG) induce downstream signaling events including the translocation of C1-domain-containing proteins toward the plasma membrane. Here, we introduce three light-sensitive DAGs, termed PhoDAGs, which feature a photoswitchable acyl chain. The PhoDAGs are inactive in the dark and promote the translocation of proteins that feature C1 domains toward the plasma membrane upon a flash of UV-A light. This effect is quickly reversed after the termination of photostimulation or by irradiation with blue light, permitting the generation of oscillation patterns. Both protein kinase C and Munc13 can thus be put under optical control. PhoDAGs control vesicle release in excitable cells, such as mouse pancreatic islets and hippocampal neurons, and modulate synaptic transmission in Caenorhabditis elegans. As such, the PhoDAGs afford an unprecedented degree of spatiotemporal control and are broadly applicable tools to study DAG signaling

    Extrarenal Pelvis in a Cat - Diagnosis by Scintigraphy

    Get PDF
    Background: In people, extrarenal pelvis is a normal anatomical variant, characterized by the protusion of the pelvis out of the renal hilum, which can be associated with other anomalies, or predispose to stasis or infection. While other diagnostic imaging methods provide anatomical and morphological information about the kidney, scintigraphy allows to determine the renal function and has greater sensitivity in the detection of functional alterations. The aim of this work is to report the case of an asymptomatic cat diagnosed with extrarenal pelvis detected by scintigraphy, which presented alterations in laboratory and renal imaging tests, and absence of associated obstructive process. Case: A 7-year-old mixed-breed female cat was evaluated for a routine health assessment at the Veterinary Teaching Hospital of the Federal University of Rio Grande do Sul (HCV-UFRGS). When performing the imaging and laboratory tests, renal alterations compatible with chronic kidney disease were found in the abdominal ultrasonography examination and in serum creatinine levels. Therefore, it was decided to perform scintigraphy evaluation to better assess renal function. Dynamic renal scintigraphy with 99mTcDTPA revealed an evident concentration of the radiotracer in the left kidney with effective elimination only after the diuretic stimulus. The right kidney exhibited less concentration of the radiotracer but showed effective elimination before the diuretic stimulus. Image analysis suggested the presence of an extrarenal pelvis on the left side. The relative renal uptake was 68% for the left kidney and 32% for the right kidney. The glomerular filtration rate was 1.65 mL/min/kg. Static renal scintigraphy with 99mTcDMSA revealed irregularity in the distribution of the radiotracer in both kidneys, showing less activity in the caudal pole of the left kidney. The right kidney was apparently reduced and with less activity, especially in the medial portion. The relative renal uptake was 65% for the left kidney and 35% for right kidney, while the absolute renal uptake of the left kidney was 33% and that of the right kidney was 17%. The alteration described in the left kidney, in correlation with dynamic renal scintigraphy, suggested an aspect of lower activity in the caudal pole due to the presence of activity in the extrarenal pelvis. The left kidney was classified as presenting normal renal function and there was moderate to severe deficit of renal function on the right side. Discussion: Chronic kidney disease may be present before clinical signs and biochemical abnormalities are identified. In this report, the animal was referred for a routine evaluation and showed no clinical signs nor alterations on physical examination. However, as renal morphological alterations were seen on ultrasonography and the cat presented mild azotemia, it was decided to perform two renal scintigraphy exams. Despite the radiotracer elimination from the left kidney was seen only after the diuretic stimulus, dynamic renal scintigraphy did not show any obstructive process. This delay on elimination was probably a result of the anatomical variant called extrarenal pelvis. In the static renal scintigraphy, it was possible to evaluate morphological changes in the kidneys and suggest less activity in the caudal pole of the left kidney, due to the presence of activity in the extrarenal pelvis, apparently causing the mentioned defect. The correct diagnosis of morphological changes is essential and for this purpose the best combination of imaging tests is necessary. Renal scintigraphy was fundamental, in this case, for the diagnosis of extrarenal pelvis in one of the kidneys, an abnormality not reported in the feline species within the literature researched by the authors. In addition, renal scintigraphy helped to guide the clinical management of the patient described in this report. Keywords: renal scintigraphy, chronic kidney disease, ultrasonography, nuclear medicine. Título: Pelve extrarrenal em uma gata - diagnóstico por cintilografia. Descritores: cintilografia renal, doença renal crônica, ultrassonografia, medicina nuclear

    Produção de sementes de azevém (Lolium multiflorum Lam.) BRS Ponteio em função da época de diferimento.

    Get PDF
    Muitas áreas de produção de sementes de azevém (Lolium multiflorum Lam.) no sul do Brasil são utilizadas também para o pastejo de bovinos.Número especial. Trabalho 629. Edição dos Resumos do 19º Congresso Brasileiro de Sementes, Foz do Iguaçu, set. 2015

    Instrumento para monitoramento da qualidade no processo de produção de sementes de leguminosas forrageiras de clima temperado.

    Get PDF
    A produção de sementes forrageiras de clima temperado no Rio Grande do Sul atravessa período de reorganização e qualificação técnica, com muitos produtores buscando se adequar aos padrões e normas legais.Número especial. Trabalho 631. Edição dos Resumos do 19º Congresso Brasileiro de Sementes, Foz do Iguaçu, set. 2015

    Análise de custos e risco econômico na produção de sementes de trevo-branco.

    Get PDF
    O objetivo do trabalho foi fazer uma avaliação econômica da produção de sementes ao longo de três anos.Editora técnica Claudia Cristina Gulias Gomes

    Extrarenal pelvis in a cat : diagnosis by scintigraphy

    Get PDF
    Background: In people, extrarenal pelvis is a normal anatomical variant, characterized by the protusion of the pelvis out of the renal hilum, which can be associated with other anomalies, or predispose to stasis or infection. While other diagnostic imaging methods provide anatomical and morphological information about the kidney, scintigraphy allows to determine the renal function and has greater sensitivity in the detection of functional alterations. The aim of this work is to report the case of an asymptomatic cat diagnosed with extrarenal pelvis detected by scintigraphy, which presented alterations in laboratory and renal imaging tests, and absence of associated obstructive process. Case: A 7-year-old mixed-breed female cat was evaluated for a routine health assessment at the Veterinary Teaching Hospital of the Federal University of Rio Grande do Sul (HCV-UFRGS). When performing the imaging and laboratory tests, renal alterations compatible with chronic kidney disease were found in the abdominal ultrasonography examination and in serum creatinine levels. Therefore, it was decided to perform scintigraphy evaluation to better assess renal function. Dynamic renal scintigraphy with 99mTcDTPA revealed an evident concentration of the radiotracer in the left kidney with effective elimination only after the diuretic stimulus. The right kidney exhibited less concentration of the radiotracer but showed effective elimination before the diuretic stimulus. Image analysis suggested the presence of an extrarenal pelvis on the left side. The relative renal uptake was 68% for the left kidney and 32% for the right kidney. The glomerular filtration rate was 1.65 mL/min/kg. Static renal scintigraphy with 99mTcDMSA revealed irregularity in the distribution of the radiotracer in both kidneys, showing less activity in the caudal pole of the left kidney. The right kidney was apparently reduced and with less activity, especially in the medial portion. The relative renal uptake was 65% for the left kidney and 35% for right kidney, while the absolute renal uptake of the left kidney was 33% and that of the right kidney was 17%. The alteration described in the left kidney, in correlation with dynamic renal scintigraphy, suggested an aspect of lower activity in the caudal pole due to the presence of activity in the extrarenal pelvis. The left kidney was classified as presenting normal renal function and there was moderate to severe deficit of renal function on the right side. Discussion: Chronic kidney disease may be present before clinical signs and biochemical abnormalities are identified. In this report, the animal was referred for a routine evaluation and showed no clinical signs nor alterations on physical examination. However, as renal morphological alterations were seen on ultrasonography and the cat presented mild azotemia, it was decided to perform two renal scintigraphy exams. Despite the radiotracer elimination from the left kidney was seen only after the diuretic stimulus, dynamic renal scintigraphy did not show any obstructive process. This delay on elimination was probably a result of the anatomical variant called extrarenal pelvis. In the static renal scintigraphy, it was possible to evaluate morphological changes in the kidneys and suggest less activity in the caudal pole of the left kidney, due to the presence of activity in the extrarenal pelvis, apparently causing the mentioned defect. The correct diagnosis of morphological changes is essential and for this purpose the best combination of imaging tests is necessary. Renal scintigraphy was fundamental, in this case, for the diagnosis of extrarenal pelvis in one of the kidneys, an abnormality not reported in the feline species within the literature researched by the authors. In addition, renal scintigraphy helped to guide the clinical management of the patient described in this report

    Measurement of the branching fraction and CP content for the decay B(0) -> D(*+)D(*-)

    Get PDF
    This is the pre-print version of the Article. The official published version can be accessed from the links below. Copyright @ 2002 APS.We report a measurement of the branching fraction of the decay B0→D*+D*- and of the CP-odd component of its final state using the BABAR detector. With data corresponding to an integrated luminosity of 20.4  fb-1 collected at the Υ(4S) resonance during 1999–2000, we have reconstructed 38 candidate signal events in the mode B0→D*+D*- with an estimated background of 6.2±0.5 events. From these events, we determine the branching fraction to be B(B0→D*+D*-)=[8.3±1.6(stat)±1.2(syst)]×10-4. The measured CP-odd fraction of the final state is 0.22±0.18(stat)±0.03(syst).This work is supported by DOE and NSF (USA), NSERC (Canada), IHEP (China), CEA and CNRS-IN2P3 (France), BMBF (Germany), INFN (Italy), NFR (Norway), MIST (Russia), and PPARC (United Kingdom). Individuals have received support from the A.P. Sloan Foundation, Research Corporation, and Alexander von Humboldt Foundation

    Measurement of D-s(+) and D-s(*+) production in B meson decays and from continuum e(+)e(-) annihilation at √s=10.6 GeV

    Get PDF
    This is the pre-print version of the Article. The official published version can be accessed from the links below. Copyright @ 2002 APSNew measurements of Ds+ and Ds*+ meson production rates from B decays and from qq̅ continuum events near the Υ(4S) resonance are presented. Using 20.8 fb-1 of data on the Υ(4S) resonance and 2.6 fb-1 off-resonance, we find the inclusive branching fractions B(B⃗Ds+X)=(10.93±0.19±0.58±2.73)% and B(B⃗Ds*+X)=(7.9±0.8±0.7±2.0)%, where the first error is statistical, the second is systematic, and the third is due to the Ds+→φπ+ branching fraction uncertainty. The production cross sections σ(e+e-→Ds+X)×B(Ds+→φπ+)=7.55±0.20±0.34pb and σ(e+e-→Ds*±X)×B(Ds+→φπ+)=5.8±0.7±0.5pb are measured at center-of-mass energies about 40 MeV below the Υ(4S) mass. The branching fractions ΣB(B⃗Ds(*)+D(*))=(5.07±0.14±0.30±1.27)% and ΣB(B⃗Ds*+D(*))=(4.1±0.2±0.4±1.0)% are determined from the Ds(*)+ momentum spectra. The mass difference m(Ds+)-m(D+)=98.4±0.1±0.3MeV/c2 is also measured.This work was supported by DOE and NSF (USA), NSERC (Canada), IHEP (China), CEA and CNRS-IN2P3 (France), BMBF (Germany), INFN (Italy), NFR (Norway), MIST (Russia), and PPARC (United Kingdom). Individuals have received support from the Swiss NSF, A. P. Sloan Foundation, Research Corporation, and Alexander von Humboldt Foundation
    • …
    corecore