181 research outputs found

    PACCE: Perl Algorithm to Compute Continuum and Equivalent Widths

    Full text link
    We present Perl Algorithm to Compute continuum and Equivalent Widths (pacce). We describe the methods used in the computations and the requirements for its usage. We compare the measurements made with pacce and "manual" ones made using iraf splot task. These tests show that for SSP models the equivalent widths strengths are very similar (differences <0.2A) for both measurements. In real stellar spectra, the correlation between both values is still very good, but with differences of up to 0.5A. pacce is also able to determine mean continuum and continuum at line center values, which are helpful in stellar population studies. In addition, it is also able to compute the uncertainties in the equivalent widths using photon statistics. The code is made available for the community through the web at http://www.if.ufrgs.br/~riffel/software.html.Comment: 8 pages, 5 figures, accepted by Astrophysics and Space Scienc

    Combinatorial activity of flavonoids with antibiotics against drug resistant Staphylococcus aureus

    Get PDF
    The use of resistance-modifying agents is a potential strategy that is used to prolong the effective life of antibiotics in the face of increasing antibiotic resistance. Since certain flavonoids are potent bacterial efflux pump inhibitors, we assessed morin, rutin, quercetin, hesperidin, and (+)-catechin for their combined activity with the antibiotics ciprofloxacin, tetracycline, erythromycin, oxacillin, and ampicillin against drug-resistant strains of Staphylococcus aureus, including methicillin-resistant S. aureus. Four established methods were used to determine the combined efficacy of each combination: microdilution checkerboard assays, time-kill determinations, the Etest, and dual disc-diffusion methods. The cytotoxicity of the flavonoids was additionally evaluated in a mouse fibroblast cell line. Quercetin and its isomer morin decreased by 3- to 16-fold the minimal inhibitory concentration of ciprofloxacin, tetracycline, and erythromycin against some S. aureus strains. Rutin, hesperidin, and (+)-catechin did not promote any potentiation of antibiotics. Despite the potential cytotoxicity of these phytochemicals at a high concentration (fibroblast IC50 of 41.8 and 67.5mg/L, respectively), quercetin is commonly used as a supplement for several therapeutic purposes. All the methods, with exception of the time-kill assay, presented a high degree of congruence without any apparent strain specificity.This work was supported by Operational Program for Competitiveness Factors—COMPETE, FCT/MEC (PIDDAC), and FEDER through Projects Bioresist—PTDC/EBB-EBI/ 105085/2008; Phytodisinfectants—PTDC/DTP-SAP/1078/ 2012 (COMPETE: FCOMP-01-0124-FEDER-028765) and the PhD grants awarded to Ana Abreu (SFRH/BD/84393/ 2012) and Anabela Borges (SFRH/BD/63398/2009). The authors are very grateful to Professor Simon Gibbons (De- partment of Pharmaceutical and Biological Chemistry, The School of Pharmacy, UCL School of Pharmacy, London) for providing the bacterial strains.info:eu-repo/semantics/publishedVersio

    Low-diffusion Xe-He gas mixtures for rare-event detection: electroluminescence yield

    Get PDF
    High pressure xenon Time Projection Chambers (TPC) based on secondary scintillation (electroluminescence) signal amplification are being proposed for rare event detection such as directional dark matter, double electron capture and double beta decay detection. The discrimination of the rare event through the topological signature of primary ionisation trails is a major asset for this type of TPC when compared to single liquid or double-phase TPCs, limited mainly by the high electron diffusion in pure xenon. Helium admixtures with xenon can be an attractive solution to reduce the electron diffu- sion significantly, improving the discrimination efficiency of these optical TPCs. We have measured the electroluminescence (EL) yield of Xe–He mixtures, in the range of 0 to 30% He and demonstrated the small impact on the EL yield of the addition of helium to pure xenon. For a typical reduced electric field of 2.5 kV/cm/bar in the EL region, the EL yield is lowered by ∼ 2%, 3%, 6% and 10% for 10%, 15%, 20% and 30% of helium concentration, respectively. This decrease is less than what has been obtained from the most recent simulation framework in the literature. The impact of the addition of helium on EL statistical fluctuations is negligible, within the experimental uncertainties. The present results are an important benchmark for the simulation tools to be applied to future optical TPCs based on Xe-He mixtures. [Figure not available: see fulltext.]

    The NEXT White (NEW) detector

    Get PDF
    Conceived to host 5 kg of xenon at a pressure of 15 bar in the fiducial volume, the NEXT-White apparatus is currently the largest high pressure xenon gas TPC using electroluminescent amplification in the world. It is also a 1:2 scale model of the NEXT-100 detector for Xe-136 beta beta 0 nu decay searches, scheduled to start operations in 2019. Both detectors measure the energy of the event using a plane of photomultipliers located behind a transparent cathode. They can also reconstruct the trajectories of charged tracks in the dense gas of the TPC with the help of a plane of silicon photomultipliers located behind the anode. A sophisticated gas system, common to both detectors, allows the high gas purity needed to guarantee a long electron lifetime. NEXT-White has been operating since October 2016 at the Laboratorio Subterraneo de Canfranc (LSC), in Spain. This paper describes the detector and associated infrastructures, as well as the main aspects of its initial operation

    Measurement of radon-induced backgrounds in the NEXT double beta decay experiment

    Get PDF
    The measurement of the internal 222Rn activity in the NEXT-White detector during the so-called Run-II period with 136Xe-depleted xenon is discussed in detail, together with its implications for double beta decay searches in NEXT. The activity is measured through the alpha production rate induced in the fiducial volume by 222Rn and its alpha-emitting progeny. The specific activity is measured to be (38.1 ± 2.2 (stat.) ± 5.9 (syst.)) mBq/m3. Radon-induced electrons have also been characterized from the decay of the 214Bi daughter ions plating out on the cathode of the time projection chamber. From our studies, we conclude that radon-induced backgrounds are sufficiently low to enable a successful NEXT-100 physics program, as the projected rate contribution should not exceed 0.1 counts/yr in the neutrinoless double beta decay sample

    Sensitivity of the NEXT experiment to Xe-124 double electron capture

    Get PDF
    Double electron capture by proton-rich nuclei is a second-order nuclear process analogous to double beta decay. Despite their similarities, the decay signature is quite different, potentially providing a new channel to measure the hypothesized neutrinoless mode of these decays. The Standard-Model-allowed two-neutrino double electron capture (2¿EC EC) has been predicted for a number of isotopes, but only observed in 78Kr, 130Ba and, recently, 124Xe. The sensitivity to this decay establishes a benchmark for the ultimate experimental goal, namely the potential to discover also the lepton-number-violating neutrinoless version of this process, 0¿EC EC. Here we report on the current sensitivity of the NEXT-White detector to 124Xe 2¿EC EC and on the extrapolation to NEXT-100. Using simulated data for the 2¿EC EC signal and real data from NEXT-White operated with 124Xe-depleted gas as background, we define an optimal event selection that maximizes the NEXT-White sensitivity. We estimate that, for NEXT-100 operated with xenon gas isotopically enriched with 1 kg of 124Xe and for a 5-year run, a sensitivity to the 2¿EC EC half-life of 6 × 1022 y (at 90% confidence level) or better can be reached. [Figure not available: see fulltext.

    Demonstration of the event identification capabilities of the NEXT-White detector

    Get PDF
    [EN] In experiments searching for neutrinoless double-beta decay, the possibility of identifying the two emitted electrons is a powerful tool in rejecting background events and therefore improving the overall sensitivity of the experiment. In this paper we present the first measurement of the efficiency of a cut based on the different event signatures of double and single electron tracks, using the data of the NEXT-White detector, the first detector of the NEXT experiment operating underground. Using a 228Th calibration source to produce signal-like and background-like events with energies near 1.6 MeV, a signal efficiency of 71.6 ± 1.5 stat ± 0.3 sys% for a background acceptance of 20.6 ± 0.4 stat ± 0.3 sys% is found, in good agreement with Monte Carlo simulations. An extrapolation to the energy region of the neutrinoless double beta decay by means of Monte Carlo simulations is also carried out, and the results obtained show an improvement in background rejection over those obtained at lower energies.The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787NEXT; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Marie Sklodowska-Curie Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economia y Competitividad and the Ministerio de Ciencia, Innovacion y Universidades of Spain under grants FIS2014-53371-C04, RTI2018-095979, the Severo Ochoa Program SEV-2014-0398 and the Maria de Maetzu Program MDM-2016-0692; the GVA of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FIS-NUC/2525/2014, under project UID/FIS/04559/2013 to fund the activities of LIBPhys, and under grants PD/BD/FBD/105921/2014, SFRH/BPD/109180/2015 and SFRH/BPD/76842/2011; the U.S. Department of Energy under contracts number DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M) and DE-SC0019223/DE-SC0019054 (University of Texas at Arlington); and the University of Texas at Arlington. DGD acknowledges Ramon y Cajal program (Spain) under contract number RYC-2015-18820. We also warmly acknowledge the Laboratori Nazionali del Gran Sasso (LNGS) and the Dark Side collaboration for their help with TPB coating of various parts of the NEXT-White TPC. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.Ferrario, P.; Benlloch-Rodríguez, J.; Díaz López, G.; Hernando Morata, J.; Kekic, M.; Renner, J.; Usón, A.... (2019). Demonstration of the event identification capabilities of the NEXT-White detector. Journal of High Energy Physics (Online). (10):1-17. https://doi.org/10.1007/JHEP10(2019)052S11710M. Fukugita and T. Yanagida, Baryogenesis without grand unification, Phys. Lett.B 174 (1986) 45 [ INSPIRE ].EXO-200 collaboration, Improved measurement of the 2νββ half-life of136Xe with the EXO-200 detector, Phys. Rev.C 89 (2014) 015502 [ arXiv:1306.6106 ] [ INSPIRE ].XENON collaboration, Dark matter search results from a one ton-year exposure of XENON1T, Phys. Rev. Lett.121 (2018) 111302 [ arXiv:1805.12562 ] [ INSPIRE ].Caltech-Neuchâtel-PSI collaboration, Search for ββ decay in136Xe: new results from the Gotthard experiment, Phys. Lett.B 434 (1998) 407 [ INSPIRE ].NEXT collaboration, First proof of topological signature in the high pressure xenon gas TPC with electroluminescence amplification for the NEXT experiment, JHEP01 (2016) 104 [ arXiv:1507.05902 ] [ INSPIRE ].NEXT collaboration, The Next White (NEW) detector, 2018 JINST13 P12010 [ arXiv:1804.02409 ] [ INSPIRE ].M. Redshaw, E. Wingfield, J. McDaniel and E.G. Myers, Mass and double-beta-decay Q value of136Xe, Phys. Rev. Lett.98 (2007) 053003 [ INSPIRE ].NEXT collaboration, Initial results on energy resolution of the NEXT-White detector, 2018 JINST13 P10020 [ arXiv:1808.01804 ] [ INSPIRE ].NEXT collaboration, Energy calibration of the NEXT-White detector with 1% resolution near Qββ of136Xe, arXiv:1905.13110 [ INSPIRE ].NEXT collaboration, Electron drift properties in high pressure gaseous xenon, 2018 JINST13 P07013 [ arXiv:1804.01680 ] [ INSPIRE ].T.H. Cormen, C. Stein, R.L. Rivest and C.E. Leiserson, Introduction to algorithms, 2nd ed., McGraw-Hill Higher Education, U.S.A. (2001).NEXT collaboration, Calibration of the NEXT-White detector using83mKr decays, 2018 JINST13 P10014 [ arXiv:1804.01780 ] [ INSPIRE ].J. Martín-Albo, The NEXT experiment for neutrinoless double beta decay searches, Ph.D. thesis, Valencia U., IFIC, Valencia, Spain (2015).GEANT4 collaboration, GEANT4: a simulation toolkit, Nucl. Instrum. Meth.A 506 (2003) 250 [ INSPIRE ].J.J. Gomez-Cadenas et al., Sense and sensitivity of double beta decay experiments, JCAP06 (2011) 007 [ arXiv:1010.5112 ] [ INSPIRE ].NEXT collaboration, Radiogenic backgrounds in the NEXT double beta decay experiment, arXiv:1905.13625 [ INSPIRE ].NEXT collaboration, Background rejection in NEXT using deep neural networks, 2017 JINST12 T01004 [ arXiv:1609.06202 ] [ INSPIRE ].NEXT collaboration, Application and performance of an ML-EM algorithm in NEXT, 2017 JINST12 P08009 [ arXiv:1705.10270 ] [ INSPIRE ].NEXT collaboration, Secondary scintillation yield of xenon with sub-percent levels of CO2 additive for rare-event detection, Phys. Lett.B 773 (2017) 663 [ arXiv:1704.01623 ] [ INSPIRE ].NEXT collaboration, Electroluminescence TPCs at the thermal diffusion limit, JHEP01 (2019) 027 [ arXiv:1806.05891 ] [ INSPIRE ].R. Felkai et al., Helium-xenon mixtures to improve the topological signature in high pressure gas xenon TPCs, Nucl. Instrum. Meth.A 905 (2018) 82 [ arXiv:1710.05600 ] [ INSPIRE ].NEXT collaboration, Electron drift and longitudinal diffusion in high pressure xenon-helium gas mixtures, 2019 JINST14 P08009 [ arXiv:1902.05544 ] [ INSPIRE ].NEXT collaboration, Sensitivity of NEXT-100 to neutrinoless double beta decay, JHEP05 (2016) 159 [ arXiv:1511.09246 ] [ INSPIRE ].J. Muñoz Vidal, The NEXT path to neutrino inverse hierarchy, Ph.D. thesis, Valencia U., IFIC, Valencia, Spain (2018)
    corecore