291 research outputs found
Occurrence of heavy metals (Hg, Cd, and Pb) and polychlorinated biphenyls in salted anchovies.
The most popular brands of salted anchovies (Engraulis encrasicolus) from the Mediterranean Sea and Atlantic Ocean were purchased from several Italian supermarkets and grocery stores. Heavy metal (Hg, Cd, and Pb) and polychlorinated biphenyl (PCB) levels were determined and assessed by comparing the concentrations in these samples with the maximum permissible limits set by the European Union (Reg EC 629/2008 and Reg EC 1881/2006 [Off. J. Eur. Union L 173:3-9 and 364:5-24, respectively]). The Hg and Cd levels were higher than those of Pb in all samples examined. For Hg and Pb, the concentrations recorded in this study were below the authorized limits, while an appreciable percentage of samples from both locations (Mediterranean Sea, 35%, and Atlantic Ocean, 25%) showed Cd levels exceeding the threshold recommended for human consumption. Concerning PCBs, the results of principal component analysis showed that samples from the two different marine areas appeared to be discriminate, with Mediterranean anchovies more contaminated than the others, in spite of their lower lipid content. However, anchovy samples from both locations had dioxinlike-PCB levels (Mediterranean Sea, 0.011 pg World Health Organization toxic equivalency [WHO-TEQ] g(-1), wet weight, and Atlantic Ocean, 0.007 pg WHO-TEQ g(-1), wet weight) that were below the WHO-TEQ maximum concentration set by European regulation. The results of this study will help in generating data needed for the assessment of heavy metal and PCB intake from this food
Geodesic acoustic modes in a fluid model of tokamak plasma : the effects of finite beta and collisionality
Starting from the Braginskii equations, relevant for the tokamak edge region,
a complete set of nonlinear equations for the geodesic acoustic modes (GAM) has
been derived which includes collisionality, plasma beta and external sources of
particle, momentum and heat. Local linear analysis shows that the GAM frequency
increases with collisionality at low radial wave number and decreases
at high . GAM frequency also decreases with plasma beta. Radial profiles
of GAM frequency for two Tore Supra shots, which were part of a collisionality
scan, are compared with these calculations. Discrepency between experiment and
theory is observed, which seems to be explained by a finite for the GAM
when flux surface averaged density and temperature are assumed to vanish. It is shown that this agreement is incidental
and self-consistent inclusion of and
responses enhances the disagreement more with at high . So the
discrepancy between the linear GAM calculation, (which persist also for more
"complete" linear models such as gyrokinetics) can probably not be resolved by
simply adding a finite
Trace Metals in Pork Meat Products Marketed in Italy: Occurrence and Health Risk Characterization
This study provides valuable information on the levels of various trace metals (Pb, Cd, Hg, Zn, Cu, Cr) in meat products (baked ham, raw ham, mortadella, cured sausage, würstel, salami) from South Italy and calculates potential health risk toxicity associated with their consumption for the total population and for children. In the samples studied metal concentrations are within the permissible legal limits (Cd: 0.01–0.03 μg g−1 w.w., Hg: 0.01–0.02 μg g−1 w.w., Zn: 5.71–7.32 μg g−1 w.w., Cu: 1.08–1.21 μg g−1 w.w., Cr: 0.15–0.23 μg g−1 w.w.), except for Pb (Pb: 0.22–0.38 μg g−1 w.w.). The estimated intake values are within the provisional tolerable daily intake limits for toxic metals and recommended daily intake values for essential metals in both tested groups. The noncarcinogenic risk values of the individual metals indicate that there is no health risk, but their combined effects might constitute a potential risk for children. Furthermore, the cumulative cancer risk of all samples studied exceeds the recommended threshold risk limit (> 10−4) in both total population and children, indicating a risk of potential health problems for consumers especially for children, who are more vulnerable to toxic metal exposure
In vitro and in vivo evaluation of a new active heat moisture exchanger.
INTRODUCTION: In order to improve the efficiency of heat moisture exchangers (HMEs), new hybrid humidifiers (active HMEs) that add water and heat to HMEs have been developed. In this study we evaluated the efficiency, both in vitro and in vivo, of a new active HME (the Performer; StarMed, Mirandola, Italy) as compared with that of existing HMEs (Hygroster and Hygrobac; Mallinckrodt, Mirandola, Italy).
METHODS: We tested the efficiency by measuring the temperature and absolute humidity (AH) in vitro using a test lung ventilated at three levels of minute ventilation (5, 10 and 15 l/min) and at two tidal volumes (0.5 and 1 l), and in vivo in 42 patients with acute lung injury (arterial oxygen tension/fractional inspired oxygen ratio 283 +/- 72 mmHg). We also evaluated the efficiency in vivo after 12 hours.
RESULTS: In vitro, passive Performer and Hygrobac had higher airway temperature and AH (29.2 +/- 0.7 degrees C and 29.2 +/- 0.5 degrees C, [P < 0.05]; AH: 28.9 +/- 1.6 mgH2O/l and 28.1 +/- 0.8 mgH2O/l, [P < 0.05]) than did Hygroster (airway temperature: 28.1 +/- 0.3 degrees C [P < 0.05]; AH: 27 +/- 1.2 mgH2O/l [P < 0.05]). Both devices suffered a loss of efficiency at the highest minute ventilation and tidal volume, and at the lowest minute ventilation. Active Performer had higher airway temperature and AH (31.9 +/- 0.3 degrees C and 34.3 +/- 0.6 mgH2O/l; [P < 0.05]) than did Hygrobac and Hygroster, and was not influenced by minute ventilation or tidal volume. In vivo, the efficiency of passive Performer was similar to that of Hygrobac but better than Hygroster, whereas Active Performer was better than both. The active Performer exhibited good efficiency when used for up to 12 hours in vivo.
CONCLUSION: This study showed that active Performer may provide adequate conditioning of inspired gases, both as a passive and as an active device
Regional hippocampal atrophy reflects memory impairment in patients with early relapsing remitting multiple sclerosis
Background: Research work has shown that hippocampal subfields are atrophic to varying extents in multiple sclerosis (MS) patients. However, studies examining the functional implications of subfield-specific hippocampal damage in early MS are limited. We aim to gain insights into the relationship between hippocampal atrophy and memory function by investigating the correlation between global and regional hippocampal atrophy and memory performance in early MS patients. Methods: From the Italian Neuroimaging Network Initiative (INNI) dataset, we selected 3D-T1-weighted brain MRIs of 219 early relapsing remitting (RR)MS and 246 healthy controls (HC) to identify hippocampal atrophic areas. At the time of MRI, patients underwent Selective-Reminding-Test (SRT) and Spatial-Recall-Test (SPART) and were classified as mildly (MMI-MS: n.110) or severely (SMI-MS: n:109) memory impaired, according to recently proposed cognitive phenotypes. Results: Early RRMS showed lower hippocampal volumes compared to HC (p < 0.001), while these did not differ between MMI-MS and SMI-MS. In MMI-MS, lower hippocampal volumes correlated with worse memory tests (r = 0.23–0.37, p ≤ 0.01). Atrophic voxels were diffuse in the hippocampus but more prevalent in cornu ammonis (CA, 79%) than in tail (21%). In MMI-MS, decreased subfield volumes correlated with decreases in memory, particularly in the right CA1 (SRT-recall: r = 0.38; SPART: r = 0.34, p < 0.01). No correlations were found in the SMI-MS group. Conclusion: Hippocampal atrophy spreads from CA to tail from early disease stages. Subfield hippocampal atrophy is associated with memory impairment in MMI-MS, while this correlation is lost in SMI-MS. This plays in favor of a limited capacity for an adaptive functional reorganization of the hippocampi in MS patients
Group 3 ITI Consensus Report: Patient-reported outcome measures associated with implant dentistry
Objectives: The aim of Working Group 3 was to focus on three topics that were assessed using patient-reported outcome measures (PROMs). These topics included the following: (a) the aesthetics of tooth and implant-supported fixed dental prostheses focusing on partially edentulous patients, (b) a comparison of fixed and removable implant-retained prostheses for edentulous populations, and (c) immediate versus early/conventional loading of immediately placed implants in partially edentate patients. PROMs include ratings of satisfaction and oral health-related quality of life (QHRQoL), as well as other indicators, that is, pain, general health-related quality of life (e.g., SF-36). Materials and methods: The Consensus Conference Group 3 participants discussed the findings of the three systematic review manuscripts. Following comprehensive discussions, participants developed consensus statements and recommendations that were then discussed in larger plenary sessions. Following this, any necessary modifications were made and approved. Results: Patients were very satisfied with the aesthetics of implant-supported fixed dental prostheses and the surrounding mucosa. Implant neck design, restorative material, or use of a provisional restoration did not influence patients’ ratings. Edentulous patients highly rate both removable and fixed implant-supported prostheses. However, they rate their ability to maintain their oral hygiene significantly higher with the removable prosthesis. Both immediate provisionalization and conventional loading receive positive patient-reported outcomes. Conclusions: Patient-reported outcome measures should be gathered in every clinical study in which the outcomes of oral rehabilitation with dental implants are investigated. PROMs, such as patients’ satisfaction and QHRQoL, should supplement other clinical parameters in our clinical definition of success
- …