6,089 research outputs found

    Direct Observation of Martensitic Phase-Transformation Dynamics in Iron by 4D Single-Pulse Electron Microscopy

    Get PDF
    The in situ martensitic phase transformation of iron, a complex solid-state transition involving collective atomic displacement and interface movement, is studied in real time by means of four-dimensional (4D) electron microscopy. The iron nanofilm specimen is heated at a maximum rate of ∼10^(11) K/s by a single heating pulse, and the evolution of the phase transformation from body-centered cubic to face-centered cubic crystal structure is followed by means of single-pulse, selected-area diffraction and real-space imaging. Two distinct components are revealed in the evolution of the crystal structure. The first, on the nanosecond time scale, is a direct martensitic transformation, which proceeds in regions heated into the temperature range of stability of the fcc phase, 1185−1667 K. The second, on the microsecond time scale, represents an indirect process for the hottest central zone of laser heating, where the temperature is initially above 1667 K and cooling is the rate-determining step. The mechanism of the direct transformation involves two steps, that of (barrier-crossing) nucleation on the reported nanosecond time scale, followed by a rapid grain growth typically in ∼100 ps for 10 nm crystallites

    Assessing Measurable Residual Disease in Chronic Myeloid Leukemia. BCR-ABL1 IS in the Avant-Garde of Molecular Hematology

    Get PDF
    Chronic myelogenous leukemia (CML) is a malignancy of the myeloid cell lineage characterized by a recurrent chromosomal abnormality: the Philadelphia chromosome, which results from the reciprocal translocation of the chromosomes 9 and 22. The Philadelphia chromosome contains a fusion gene called BCR-ABL1. The BCR-ABL1 codes for an aberrantly functioning tyrosine kinase that drives the malignant proliferation of the founding clone. The advent of tyrosine kinase inhibitors (TKI) represents a landmark in the treatment of CML, that has led to tremendous improvement in the remission and survival rates. Since the introduction of imatinib, the first TKI, several other TKI have been approved that further broadened the arsenal against CML. Patients treated with TKIs require sensitive monitoring of BCR-ABL1 transcripts with quantitative real-time polymerase chain reaction (qRT-PCT), which has become an essential part of managing patients with CML. In this review, we discuss the importance of the BCR-ABL1 assay, and we highlight the growing importance of BCR-ABL1 dynamics. We also introduce a mathematical correction for the BCR-ABL1 assay that could help homogenizing the use of the ABL1 as a control gene. Finally, we discuss the growing body of evidence concerning treatment-free remission. Along with the continuous improvement in the therapeutic arsenal against CML, the molecular monitoring of CML represents the avant-garde in the struggle to make CML a curable disease

    Adhesive and molecular friction in tribological conjunctions

    Get PDF
    This thesis investigates the underlying causes of friction and ine ciency within an internal combustion engine, focusing on the ring-liner conjunction in the vicinity of the power-stroke top dead centre reversal. In such lubricated contacts, friction is the result of the interplay between numerous kinetics, with those at micro- and nano-scale interactions being signi cantly di erent than the ones at larger scales. A modi ed Elrod's cavitation algorithm is developed to determine the microscopic tribological characteristics of the piston ring-liner contact. Predicting lubricant tran- sient behaviour is critical when the inlet reversal leads to thin lms and inherent metal-to-metal interaction. The model clearly shows that cavitation at the trailing edge of the ring-liner contact generated pre-reversal, persists after reversal and pro- motes starvation and depletion of the oil lm. Hence, this will lead to boundary friction. A fractal based boundary friction model is developed for lightly loaded asperity con- tacts, separated by diminishing small lms, usually wetted by a layer of molecules adsorbed to the tips of the asperities. In nano-scale conjunctions, a lubricant layering e ect often takes place due to the smoothness of surfaces, which is governed by the surface and lubricant properties. A molecularly thin layer of lubricant molecules can adhere to the asperities, being the last barrier against direct surface contact. As a result, boundary friction (prevailing in such diminishing gaps) is actually determined by a combination of shearing of a thin adsorbed lm, adhesion of approaching as- perities and their plastic deformation. A model for physio-chemical hydrodynamic mechanism is successfully established, describing the formation of thin adsorbed lms between asperities. This model is e ectively integrated with separately devel- oped models that predict the adhesive and plastic contact of asperities.EThOS - Electronic Theses Online ServiceGBUnited Kingdo

    Concentric double hollow grid cathode discharges

    Get PDF
    A new cathode system, consisting of two concentric spherical hollow grids with two aligned orifices, is investigated by space-resolved Langmuir probe measurements and non-linear dynamics analysis. Negative biases of this spherical hollow grids arrangement lead to the formation of two complex space charge structures in the regions of the orifices. The overall dynamics of the current-voltage characteristic (I–V characteristic) of each discharge is characterized by strong oscillatory behaviour with various waveforms correlated with jumps in the static I–V characteristics. Space-resolved measurements through the two aligned orifices of the two grids show a peak increase of the electron temperature and particle density in the regions of the two space-charge structures. The effects of the biases and Ar pressure on the overall spatial distribution of all plasma parameters are investigated. Two important working points of the concentric double hollow grid cathode discharges are revealed which could make this configuration suitable as an electron source

    The Planetary Nebula Luminosity Function at the Dawn of Gaia

    Full text link
    The [O III] 5007 Planetary Nebula Luminosity Function (PNLF) is an excellent extragalactic standard candle. In theory, the PNLF method should not work at all, since the luminosities of the brightest planetary nebulae (PNe) should be highly sensitive to the age of their host stellar population. Yet the method appears robust, as it consistently produces < 10% distances to galaxies of all Hubble types, from the earliest ellipticals to the latest-type spirals and irregulars. It is therefore uniquely suited for cross-checking the results of other techniques and finding small offsets between the Population I and Population II distance ladders. We review the calibration of the method and show that the zero points provided by Cepheids and the Tip of the Red Giant Branch are in excellent agreement. We then compare the results of the PNLF with those from Surface Brightness Fluctuation measurements, and show that, although both techniques agree in a relative sense, the latter method yields distances that are ~15% larger than those from the PNLF. We trace this discrepancy back to the calibration galaxies and argue that, due to a small systematic error associated with internal reddening, the true distance scale likely falls between the extremes of the two methods. We also demonstrate how PNLF measurements in the early-type galaxies that have hosted Type Ia supernovae can help calibrate the SN Ia maximum magnitude-rate of decline relation. Finally, we discuss how the results from space missions such as Kepler and Gaia can help our understanding of the PNLF phenomenon and improve our knowledge of the physics of local planetary nebulae.Comment: 12 pages, invited review at the conference "The Fundamental Cosmic Distance Scale: State of the Art and Gaia Perspective", to appear in Astrophysics and Space Scienc

    Quasi-linear Stokes phenomenon for the Painlev\'e first equation

    Full text link
    Using the Riemann-Hilbert approach, the Ψ\Psi-function corresponding to the solution of the first Painleve equation, yxx=6y2+xy_{xx}=6y^2+x, with the asymptotic behavior y±x/6y\sim\pm\sqrt{-x/6} as x|x|\to\infty is constructed. The exponentially small jump in the dominant solution and the coefficient asymptotics in the power-like expansion to the latter are found.Comment: version accepted for publicatio

    Matrix Models, Complex Geometry and Integrable Systems. II

    Full text link
    We consider certain examples of applications of the general methods, based on geometry and integrability of matrix models, described in hep-th/0601212. In particular, the nonlinear differential equations, satisfied by quasiclassical tau-functions are investigated. We also discuss a similar quasiclassical geometric picture, arising in the context of multidimensional supersymmetric gauge theories and the AdS/CFT correspondence.Comment: 44 pages, 10 figures, based on several lecture courses and the talks at "Complex geometry and string theory" and the Polivanov memorial seminar; misprints corrected, references adde

    Performance of fully instrumented detector planes of the forward calorimeter of a Linear Collider detector

    Get PDF
    Detector-plane prototypes of the very forward calorimetry of a future detector at an e+e- collider have been built and their performance was measured in an electron beam. The detector plane comprises silicon or GaAs pad sensors, dedicated front-end and ADC ASICs, and an FPGA for data concentration. Measurements of the signal-to-noise ratio and the response as a function of the position of the sensor are presented. A deconvolution method is successfully applied, and a comparison of the measured shower shape as a function of the absorber depth with a Monte-Carlo simulation is given.Comment: 25 pages, 32 figures, revised version following comments from referee

    First experience in human beings with a permanently implantable intrasac pressure transducer for monitoring endovascular repair of abdominal aortic aneurysms

    Get PDF
    ObjectivesEndovascular stent graft repair of abdominal aortic aneurysms (AAAs) prevents rupture by excluding the aneurysm sac from systemic arterial pressure. Current surveillance protocols after endovascular aneurysm repair (EVAR) follow secondary markers of sac pressurization, namely, endoleak and sac enlargement. We report the first clinical experience with the use of a permanently implantable, ultrasound-activated remote pressure transducer to measure intrasac pressure after EVAR.MethodsOver 7 months, 14 patients underwent EVAR of an infrarenal abdominal aortic aneurysm with implantation of an ultrasound-activated remote pressure transducer fixed to the outside of the stent graft and exposed to the excluded aortic sac. Twelve patients received modular bifurcated stent grafts, and 2 patients received aortouniiliac devices. Intrasac pressures were measured directly with an intravascular catheter and by the remote sensor at stent-graft deployment. Follow-up sac pressures were measured with a remote sensor and correlated with systemic arterial pressure at every follow-up visit. Mean follow-up was 2.6 ±1.9 months.ResultsExcellent concordance was found between catheter-derived and transducer-derived intrasac pressssure intraoperatively. Pulsatile waveforms were seen in all functioning transducers at each evaluation interval. One implant ceased to function at 2 months of follow-up. In 1 patient a type I endoleak was diagnosed on 1-month computed tomography (CT) scans; 3 type II endoleaks were observed. Those patients with complete exclusion of the aneurysm on CT scans had a significant difference in systemic and sac systolic pressures initially (P < .001) and at 1 month (P < .001). Initial sac diastolic pressures were higher than systemic diastolic pressures (P < .001). The ratio of systemic to sac systolic pressure increased over time in those patients with complete aneurysm exclusion (P < .001). Four of 6 patients with no endoleak and greater than 1-month follow-up had diminution of sac systolic pressure to 40 mm Hg or less by 3 months.ConclusionThis is the first report of a totally implantable chronic pressure transducer to monitor the results of EVAR in human beings. Aneurysm exclusion leads to gradual diminution of sac pressure over several months. Additional clinical follow-up will be necessary to determine whether aneurysm sac pressure monitoring can replace CT in the long-term surveillance of patients after EVAR
    corecore