540 research outputs found
Enhanced selectivity towards O2 and H2 dissociation on ultrathin Cu films on Ru(0001)
The following article appeared in Journal of Chemical Physics 137.7 (2012): 074706 and may be found at http://scitation.aip.org/content/aip/journal/jcp/137/7/10.1063/1.4746942The reactivity of Cu monolayer (ML) and bilayer films grown on Ru(0001) towards O2 and H2 has been investigated. O2 initial sticking coefficients were determined using the King and Wells method in the incident energy range 40-450 meV, and compared to the corresponding values measured on clean Ru(0001) and Cu(111) surfaces. A relative large O2 sticking coefficient (∼0.5-0.8) was measured for 1 ML Cu and even 2 ML Cu/Ru(0001). At low incident energies, this is one order of magnitude larger than the value observed on Cu(111). In contrast, the corresponding reactivity to H2 was near zero on both Cu monolayer and bilayer films, for incident energies up to 175 meV. Water adsorption on 2 ML Cu/Ru(0001) was found to behave quite differently than on the Ru(0001) and Cu(111) surfaces. Our study shows that Cu/Ru(0001) is a highly selective system, which presents a quite different chemical reactivity towards different species in the same range of collision energiesThe authors gratefully acknowledge the financial support by the Ministerio de Educación y Ciencia through projects CONSOLIDER-INGENIO 2010 on Molecular Nanoscience and FIS2007-61114 and Comunidad de Madrid through the program NANOMAGNET S-0505/MAT/0194. P.P. acknowledges support through the Marie Curie AMAROUT EU action and the Spanish MICINN “Juan de la Cierva” contrac
Photoreceptor Inner Segment Morphology in Best Vitelliform Macular Dystrophy
PURPOSE
To characterize outer retina structure in best vitelliform macular dystrophy (BVMD) and to determine the effect of macular lesions on overlying and adjacent photoreceptors.
METHODS
Five individuals with BVMD were followed prospectively with spectral domain optical coherence tomography and confocal and nonconfocal split-detector adaptive optics scanning light ophthalmoscopy (AOSLO). The AOSLO cone photoreceptor mosaic images were obtained within and around retinal lesions. Cone density was measured inside and outside lesions. In 2 subjects, densities were compared with published measurements acquired ∼2.5 years before. One subject was imaged 3 times over a 5-month period.
RESULTS
The AOSLO imaging demonstrated that photoreceptor morphology within BVMD retinal lesions was highly variable depending on the disease stage, with photoreceptor structure present even in advanced disease. The AOSLO imaging was repeatable even in severe disease over short-time and long-time intervals. Photoreceptor density was normal in retinal areas immediately adjacent to lesions and stable over ∼2.5 years. Mobile disk-like structures possibly representing subretinal macrophages were also observed.
CONCLUSION
Combined confocal and nonconfocal split-detector AOSLO imaging reveals substantial variability within clinical lesions in all stages of BVMD. Longitudinal cellular photoreceptor imaging could prove a powerful tool for understanding disease progression and monitoring emerging therapeutic treatment response in inherited degenerations such as BVMD
Velocity-selected molecular pulses produced by an electric guide
Electrostatic velocity filtering is a technique for the production of
continuous guided beams of slow polar molecules from a thermal gas. We extended
this technique to produce pulses of slow molecules with a narrow velocity
distribution around a tunable velocity. The pulses are generated by
sequentially switching the voltages on adjacent segments of an electric
quadrupole guide synchronously with the molecules propagating at the desired
velocity. This technique is demonstrated for deuterated ammonia (ND),
delivering pulses with a velocity in the range of and a
relative velocity spread of at FWHM. At velocities around
, the pulses contain up to molecules each. The data are
well reproduced by Monte-Carlo simulations, which provide useful insight into
the mechanisms of velocity selection.Comment: 8 pages, 6 figure
Collision Dynamics and Solvation of Water Molecules in a Liquid Methanol Film
Environmental molecular beam experiments are used to examine water
interactions with liquid methanol films at temperatures from 170 K to 190 K. We
find that water molecules with 0.32 eV incident kinetic energy are efficiently
trapped by the liquid methanol. The scattering process is characterized by an
efficient loss of energy to surface modes with a minor component of the
incident beam that is inelastically scattered. Thermal desorption of water
molecules has a well characterized Arrhenius form with an activation energy of
0.47{\pm}0.11 eV and pre-exponential factor of 4.6 {\times} 10^(15{\pm}3)
s^(-1). We also observe a temperature dependent incorporation of incident water
into the methanol layer. The implication for fundamental studies and
environmental applications is that even an alcohol as simple as methanol can
exhibit complex and temperature dependent surfactant behavior.Comment: 8 pages, 5 figure
Photoionization Broadening of the 1S-2S Transition in a Beam of Atomic Hydrogen
We consider the excitation dynamics of the two-photon \sts transition in a
beam of atomic hydrogen by 243 nm laser radiation. Specifically, we study the
impact of ionization damping on the transition line shape, caused by the
possibility of ionization of the 2S level by the same laser field. Using a
Monte-Carlo simulation, we calculate the line shape of the \sts transition for
the experimental geometry used in the two latest absolute frequency
measurements (M. Niering {\it et al.}, PRL 84, 5496 (2000) and M. Fischer {\it
et al.}, PRL 92, 230802 (2004)). The calculated line shift and line width are
in excellent agreement with the experimentally observed values. From this
comparison we can verify the values of the dynamic Stark shift coefficient for
the \sts transition for the first time on a level of 15%. We show that the
ionization modifies the velocity distribution of the metastable atoms, the line
shape of the \sts transition, and has an influence on the derivation of its
absolute frequency.Comment: 10 pages, 5 figure
Is it possible to detect gravitational waves with atom interferometers?
We investigate the possibility to use atom interferometers to detect
gravitational waves. We discuss the interaction of gravitational waves with an
atom interferometer and analyze possible schemes
An ellipsoidal mirror for focusing neutral atomic and molecular beams
Manipulation of atomic and molecular beams is essential to atom optics applications including atom lasers, atom lithography, atom interferometry and neutral atom microscopy. The manipulation of charge-neutral beams of limited polarizability, spin or excitation states remains problematic, but may be overcome by the development of novel diffractive or reflective optical elements. In this paper, we present the first experimental demonstration of atom focusing using an ellipsoidal mirror. The ellipsoidal mirror enables stigmatic off-axis focusing for the first time and we demonstrate focusing of a beam of neutral, ground-state helium atoms down to an approximately circular spot, (26.8±0.5) μm×(31.4±0.8) μm in size. The spot area is two orders of magnitude smaller than previous reflective focusing of atomic beams and is a critical milestone towards the construction of a high-intensity scanning helium microscope
An ellipsoidal mirror for focusing neutral atomic and molecular beams
Manipulation of atomic and molecular beams is essential to atom optics applications including atom lasers, atom lithography, atom interferometry and neutral atom microscopy. The manipulation of charge-neutral beams of limited polarizability, spin or excitation states remains problematic, but may be overcome by the development of novel diffractive or reflective optical elements. In this paper, we present the first experimental demonstration of atom focusing using an ellipsoidal mirror. The ellipsoidal mirror enables stigmatic off-axis focusing for the first time and we demonstrate focusing of a beam of neutral, ground-state helium atoms down to an approximately circular spot, (26.8±0.5) μm×(31.4±0.8) μm in size. The spot area is two orders of magnitude smaller than previous reflective focusing of atomic beams and is a critical milestone towards the construction of a high-intensity scanning helium microscope
Genetic characterization of Theileria equi infecting horses in North America: evidence for a limited source of U.S. introductions
Background:
Theileria equi is a tick-borne apicomplexan hemoparasite that causes equine piroplasmosis. This parasite has a worldwide distribution but the United States was considered to be free of this disease until recently.
Methods: We used samples from 37 horses to determine genetic relationships among North American T. equi using the 18S rRNA gene and microsatellites. We developed a DNA fingerprinting panel of 18 microsatellite markers using the first complete genome sequence of T. equi.
Results: A maximum parsimony analysis of 18S rRNA sequences grouped the samples into two major clades. The first clade (n= 36) revealed a high degree of nucleotide similarity in U.S. T. equi, with just 0–2 single nucleotide polymorphisms (SNPs) among samples. The remaining sample fell into a second clade that was genetically divergent (48 SNPs) from the other U.S. samples. This sample was collected at the Texas border, but may have originated in Mexico. We genotyped
T. equi from the U.S. using microsatellite markers and found a moderate amount of genetic diversity (2–8 alleles per locus). The field samples were mostly from a 2009 Texas outbreak (n= 22) although samples from five other states were also included in this study. Using Weir and Cockerham’s FST estimator (θ) we found strong population differentiation of the Texas and Georgia subpopulations (θ= 0.414),
which was supported by a neighbor-joining tree created with predominant single haplotypes. Single-clone infections were found in 27 of the 37 samples (73%), allowing us to identify 15 unique genotypes.
Conclusions: The placement of most T. equi into one monophyletic clade by 18S is suggestive of a limited source of introduction into the U.S. When applied to a broader cross section of worldwide samples, these molecular tools should improve source tracking of T. equi outbreaks and may help prevent the spread of this tick-borne parasite
Collimated dual species oven source and its characterisation via spatially resolved fluorescence spectroscopy
We describe the design, construction and characterisation of a collimated, dual-species oven source for generating intense beams of lithium and caesium in UHV environments. Our design produces full beam overlap for the two species. Using an aligned microtube array the FWHM of the output beam is restricted to ~ 75 milliradians, with an estimated axial brightness of 3.6x10[superscript]14 atoms s[superscript]-1 sr[superscript]-1 for Li and 7.4x10[superscript]15 atoms s[superscript]-1 sr[superscript]-1 for Cs. We measure the properties of the output beam using a spatially-resolved fluorescence technique, which allows for the extraction of additional information not accessible without spatial resolution
- …
