663 research outputs found
The resolution of a perturbed wave function into its symmetry components
Resolving perturbed wave functions into unperturbed Hamiltonian
Iterative solution of perturbation equations
Iterative solution of perturbation equation
The noise performance of electron-multiplying charge-coupled devices at X-ray energies
Electron-multiplying charge-coupled devices (EMCCDs) are used in low-light-level (L3) applications for detecting optical, ultraviolet, and near-infrared photons (10–1100 nm). The on-chip gain process is able to increase the detectability of any signal collected by the device through the multiplication of the signal before the output node. Thus, the effective readout noise can be reduced to subelectron levels, allowing the detection of single photons. However, this gain process introduces an additional noise component due to the stochastic nature of the multiplication. In optical applications, this additional noise has been characterized. The broadening of the detected peak is described by the excess noise factor. This factor tends to a value of √2 at high gain (>100x). In X-ray applications, the situation is improved by the effect that Fano factor f has on the shot noise associated with X-ray photon detection (f ≈ 0.12 at X-ray energies). In this paper, the effect of the detection of X-ray photons in silicon is assessed both analytically and through a Monte Carlo model of the gain amplification process. The excess noise on the signal is predicted (termed the modified Fano factor) for photon detection in an EM-CCD at X-ray energies. A hypothesis is made that the modified Fano factor should tend to 1.115 at high levels of gain (>10x). In order to validate the predictions made, measurements were taken using an 55 Fe source with Mn k-alpha X-ray energy of 5898 eV. These measurements allowed the hypothesis to be verified
The noise performance of electron-multiplying charge-coupled devices at soft X-ray energy values
The use of electron-multiplying charge-coupled devices (CCDs) for high-resolution soft X-ray spectroscopy has been proposed in previous studies, and the analysis that followed experimentally identified and verified a modified Fano factor for X-ray detection using an 55Fe X-ray source. However, further experiments with soft X-rays at 1000 eV were less successful, attributed to excessive split events. More recently, through the use of deep-depletion e2v CCD220 and on-chip binning, it has been possible to greatly reduce the number of split events, allowing the result for the modified Fano factor at soft X-ray energy values to be verified. This paper looks at the earlier attempt to verify the modified Fano factor at 1000 eV with e2v CCD97 and shows the issues created by splitting of the charge cloud between pixels. It then compares these earlier results with new data collected using e2v CCD220, investigating how split-event reduction allows the modified Fano factor to be verified for low-energy X-rays
First Multicharged Ion Irradiation Results from the CUEBIT Facility at Clemson University
A new electron beam ion trap (EBIT) based ion source and beamline were recently commissioned at Clemson University to produce decelerated beams of multi- to highly-charged ions for surface and materials physics research. This user facility is the first installation of a DREEBIT-designedsuperconducting trap and ion source (EBIS-SC) in the U.S. and includes custom-designed target preparation and irradiation setups. An overview of the source, beamline, and other facilities as well as results from first measurements on irradiated targets are discussed here. Results include extracted charge state distributions and first data on a series of irradiated metal-oxide-semiconductor (MOS) device targets. For the MOS devices, we show that voltage-dependent capacitance can serve as a record of theelectronic component of ion stopping power for an irradiated, encapsulated oxide target
Electron-multiplying CCDs for future soft X-ray spectrometers
CCDs have been used in several high resolution soft X-ray spectrometers for both space and terrestrial applications such as the Reflection Grating Spectrometer on XMM-Newton and the Super Advanced X-ray Emission Spectrometer at the Paul Scherrer Institut in Switzerland. However, with their ability to use multiplication gain to amplify signal and suppress readout noise, EM-CCDs are being considered instead of CCDs for future soft X-ray spectrometers. When detecting low energy X-rays, EM-CCDs are able to increase the Signal-to-Noise ratio of the device, making the X-rays much easier to detect. If the signal is also significantly split between neighbouring pixels, the increase in the size of the signal will make complete charge collection and techniques such as centroiding easier to accomplish. However, multiplication gain from an EM-CCD does cause a degradation of the energy resolution of the device and there are questions about how the high field region in an EM-CCD will behave over time in high radiation environments. This paper analyses the possible advantages and disadvantages of using EM-CCDs for high resolution soft X-ray spectroscopy and suggests in which situations using them would not only be possible, but also beneficial to the instrument
Compact CMOS camera demonstrator (C3D) for Ukube-1
The Open University, in collaboration with e2v technologies and XCAM Ltd, have been selected to fly an EO (Earth Observation) technology demonstrator and in-orbit radiation damage characterisation instrument on board the UK Space Agency's UKube-1 pilot Cubesat programme. Cubesat payloads offer a unique opportunity to rapidly build and fly space hardware for minimal cost, providing easy access to the space environment. Based around the e2v 1.3 MPixel 0.18 micron process eye-on-Si CMOS devices, the instrument consists of a radiation characterisation imager as well as a narrow field imager (NFI) and a wide field imager (WFI). The narrow and wide field imagers are expected to achieve resolutions of 25 m and 350 m respectively from a 650 km orbit, providing sufficient swathe width to view the southern UK with the WFI and London with the NFI. The radiation characterisation experiment has been designed to verify and reinforce ground based testing that has been conducted on the e2v eye-on-Si family of devices and includes TEC temperature control circuitry as well as RADFET in-orbit dosimetry. Of particular interest are SEU and SEL effects. The novel instrument design allows for a wide range of capabilities within highly constrained mass, power and space budgets providing a model for future use on similarly constrained missions, such as planetary rovers. Scheduled for launch in December 2011, this 1 year low cost programme should not only provide valuable data and outreach opportunities but also help to prove flight heritage for future missions
Experiencing space–time: the stretched lifeworlds of migrant workers in India
In the relatively rare instances when the spatialities of temporary migrant work, workers’ journeys, and labour-market negotiations have been the subject of scholarly attention, there has been little work that integrates time into the analysis. Building on a case study of low-paid and insecure migrant manual workers in the context of rapid economic growth in India, we examine both material and subjective dimensions of these workers’ spatiotemporal experiences. What does it mean to live life stretched out, multiplyattached to places across national space? What kinds of place attachments emerge for people temporarily sojourning in, rather than moving to, new places to reside and work? Our analysis of the spatiotemporalities of migrant workers’ experiences in India suggests that, over time, this group of workers use their own agency to seek to avoid the experience of humiliation and indignity in employment relations. Like David Harvey, we argue that money needs to be integrated into such analysis, along with space and time. The paper sheds light on processes of exclusion, inequality and diff erentiation, unequal power geometries, and social topographies that contrast with neoliberalist narratives of ‘Indian shining
- …