14,137 research outputs found
Strapdown calibration and alignment study. Volume 2 - Procedural and parametric trade-off analyses document Final report
Parametric and procedural tradeoffs for alignment and calibration of inertial sensing uni
Strapdown calibration and alignment study. Volume 2 - Procedural and parametric trade- off analyses document
Techniques for laboratory calibration and alignment of strapdown inertial sensing unit - procedural and parametric trade-off analyse
Stabilization and precise calibration of a continuous-wave difference frequency spectrometer by use of a simple transfer cavity
A novel, simple, and inexpensive calibration scheme for a continuous-wave difference frequency spectrometer is presented, based on the stabilization of an open transfer cavity by locking onto the output of a polarization stabilized HeNe laser. High frequency, acoustic fluctuations of the transfer cavity length are compensated with a piezoelectric transducer mounted mirror, while long term drift in cavity length is controlled by thermal feedback. A single mode Ar+ laser, used with a single mode ring dye laser in the difference frequency generation of 2–4 µm light, is then locked onto a suitable fringe of this stable cavity, achieving a very small long term drift and furthermore reducing the free running Ar+ linewidth to about 1 MHz. The dye laser scan provides tunability in the difference frequency mixing process, and is calibrated by marker fringes with the same stable cavity. Due to the absolute stability of the marker cavity, precise frequency determination of near infrared molecular transitions is achieved via interpolation between these marker fringes. It is shown theoretically that the residual error of this scheme due to the dispersion of air in the transfer cavity is quite small, and experimentally that a frequency precision on the order of 1 MHz per hour is routinely obtained with respect to molecular transitions. Review of Scientific Instruments is copyrighted by The American Institute of Physics
Pattern formation in self-propelled particles with density-dependent motility
We study the behaviour of interacting self-propelled particles, whose
self-propulsion speed decreases with their local density. By combining direct
simulations of the microscopic model with an analysis of the hydrodynamic
equations obtained by explicitly coarse graining the model, we show that
interactions lead generically to the formation of a host of patterns, including
moving clumps, active lanes and asters. This general mechanism could explain
many of the patterns seen in recent experiments and simulations
Strapdown calibration and alignment study. Volume 1 - Development document Final report
Calibration and alignment techniques for inertial sensing uni
First-Order Vortex Lattice Melting and Magnetization of YBaCuO$_{7-\delta}
We present the first non-mean-field calculation of the magnetization
of YBaCuO both above and below the flux-lattice melting
temperature . The results are in good agreement with experiment as a
function of transverse applied field . The effects of fluctuations in both
order parameter and magnetic induction are included in the
Ginzburg-Landau free energy functional: fluctuates within the
lowest Landau level in each layer, while fluctuates uniformly according to
the appropriate Boltzmann factor. The second derivative is predicted to be negative throughout the vortex liquid state and
positive in the solid state. The discontinuities in entropy and magnetization
at melting are calculated to be per flux line per layer and
~emu~cm at a field of 50 kOe.Comment: 11 pages, 4 PostScript figures in one uuencoded fil
Data compression for the Cassini radio and plasma wave instrument
The Cassini Radio and Plasma Wave Science experiment will employ data compression to make effective use of the available data telemetry bandwidth. Some compression will be achieved by use of a lossless data compression chip and some by software in a dedicated 80C85 processor. A description of the instrument and data compression system are included in this report. Also, the selection of data compression systems and acceptability of data degradation is addressed
Optical variability of the accretion disk around the intermediate mass black hole ESO 243-49 HLX-1 during the 2012 outburst
We present dedicated quasi-simultaneous X-ray (Swift) and optical (Very Large
Telescope (VLT), V- and R-band) observations of the intermediate mass black
hole candidate ESO 243-49 HLX-1 before and during the 2012 outburst. We show
that the V-band magnitudes vary with time, thus proving that a portion of the
observed emission originates in the accretion disk. Using the first quiescent
optical observations of HLX-1, we show that the stellar population surrounding
HLX-1 is fainter than V~25.1 and R~24.2. We show that the optical emission may
increase before the X-ray emission consistent with the scenario proposed by
Lasota et al. (2011) in which the regular outbursts could be related to the
passage at periastron of a star circling the intermediate mass black hole in an
eccentric orbit, which triggers mass transfer into a quasi-permanent accretion
disk around the black hole. Further, if there is indeed a delay in the X-ray
emission we estimate the mass-transfer delivery radius to be ~1e11 cm.Comment: 9 pages, 2 figures, accepted for publication in ApJ
- …