4,468 research outputs found

    A Cavitation Susceptability Meter with Optical Cavitation Monitoring-Part One: Design Concepts

    Get PDF
    This work is concerned with the design of a Cavitation Susceptibility Meter based on the use of a venturi tube for the measurement of the active cavitation nuclei concentration in water samples as a function of the applied tension. The operation of the Cavitation Susceptibility Meter is analyzed and the main considerations leading to the proposed design are illustrated and critically discussed. The results of this analysis indicate that the operational range is mainly limited by nuclei interference, flow separation and saturation (choking), and suggest to develop a Cavitation Susceptibility Meter where; (1) the flow possesses a laminar potential core throughout the venturi throat section in all operational conditions; (b) the pressure at the venturi throat is determined from the upstream pressure and the local flow velocity; (c) the detection of cavitation and the measurement of the flow velocity are carried out optically by means of a Laser Doppler Velocimeter; (d) a custom-made electronic Signal Processor incorporating a frequency counter is used for real time data generation and temporary storage; (e) a computerized system performs the final acquisition and reduction of the data

    Separation and Surface Nuclei Effects in a Cavitation Susceptibility Meter

    Get PDF
    This work is concerned with the effects of flow separation and surface nuclei on the operation of a fixed geometry Cavitation Susceptibility Meter (CSM) with laminar flow. Cavitation is induced under controlled conditions at the throat of a glass venturi tube for the measurement of the active nuclei concentration in water samples as a function of the applied tension. Both cavitation and flow velocity are monitored optically by a Laser Doppler Velocimeter. The throat pressure is determined indirectly from the upstream pressure and the local flow velocity. The results show that laminar flow separation and surface nuclei effects are the most stringent operational limitations. Separation in the diffuser increases the minimum attainable throat pressure above the susceptibility of most cavitation nuclei commonly found in technical waters. Surface nuclei can generate extensive sheet or spot cavitation at relatively high tensions even on optically finished glass surfaces. These phenomena are difficult to eliminate and bring therefore into question the practical utility of CSM's with laminar flow and fixed geometry for the measurement of the dependence of the cavitating nuclei concentration over wide ranges of the applied tension, as required for cavitation studies

    A Cavitation Susceptibility Meter with Optical Cavitation Monitoring -- Part Two: Experimental Apparatus and Results

    Get PDF
    This work in concerned with the development and operation of a Cavitation Susceptibility Meter based on the use of a venturi tube for the measurement of the active cavitation nuclei concentration in water samples as a function of the applied tension. The pressure at the venturi throat is determined from the upstream pressure and the local flow velocity without corrections for viscous effects because the flow possesses a laminar potential core in all operational conditions. The detection of cavitation and the measurement of the flow velocity are carried out optically by means of a Laser Doppler Velocimeter. A custom-made electronic Signal Processor is used for real time data generation and temporary storage and a computerized system for final data acquisition and reduction. The implementation of the whole system is described and the results of the application of the Cavitation Susceptibility Meter to the measurement of the water quality of tap water samples are presented and critically discussed with reference to the current state of knowledge on cavitation inception

    Does global liquidity help to forecast US inflation?

    Get PDF
    We construct a measure of global liquidity using the growth rates of broad money for the G7 economies. Global liquidity produces forecasts of US inflation that are significantly more accurate than the forecasts based on US money growth, Phillips curve, autoregressive and moving average models. The marginal predictive power of global liquidity is strong at three years horizons. Results are robust to alternative measures of inflation.

    Federal Reserve Information During the Great Moderation

    Get PDF
    Using data from the period 1970-1991, Romer and Romer (2000) showed that Federal Reserve forecasts of inflation and output were superior to those provided by commercial forecasters. In this paper, we show that this superior forecasting performance deteriorated after 1991. Over the decade 1992-2001, the superior forecast accuracy of the Fed held only over a very short time horizon and was limited to its forecasts of inflation. In addition, the performance of both the Fed and the commercial forecasters in predicting inflation and output, relative to that of "naive" benchmark models, dropped remarkably during this period.

    "I wanna die just like JFK / I wanna die in the USA": Libra and DeLillo’s Curation of the Kennedy Archive

    Get PDF
    Don DeLillo reimagines and revisions the Kennedy assassination in Libra.  Nicholas Branch, a retired senior analyst for the CIA, has been hired on contract to write a definitive account of the events at Dealey Plaza on November 22nd, 1963.  In the process, Branch subsumes the role of the museum curator; he meticulously combs through the received records in order to challenge accepted versions of “history”.  As the novel’s character-as-curator, Branch examines, positions, interprets, and displays the artifacts at hand to outline the numerous plots swirling around the assassination.  This paper will demonstrate how DeLillo, through Branch, reimagines the space of the novel, transforming it into a museum display that challenges the Warren Commission’s “Single-Bullet Theory” and its “Lone-Gunman Theory”, to instead suggest the possible presence of multiple shooters.  As the novel’s character-as-curator, Branch meticulously places the objects on display and leaves it to the reader to decide which view to adopt or accept

    Experimental Signals of Phase Transition

    Full text link
    The connection between the thermodynamics of charged finite nuclear systems and the asymptotically measured partitions is presented. Some open questions, concerning in particular equilibrium partitions are discussed. We show a detailed comparison of the decay patterns in Au+ C,Cu,Au central collisions and in Au quasi-projectile events. Observation of abnormally large fluctuations in carefully selected samples of data is reported as an indication of a first order phase transition (negative heat capacity) in the nuclear equation of state.Comment: 8 pages, 8th International Conference on Nucleus-Nucleus Collisions, Moscow 200

    Cavitation and flow instabilities in a 3-bladed axial inducer designed by means of a reduced order analytical model

    Full text link
    The present paper illustrates the main results of an experimental campaign conducted using the CPRTF (Cavitating Pump Rotordynamic Test Facility) at Alta S.p.A. The tests were carried out on the DAPAMITO inducer, a three-bladed axial pump designed and manufactured by Alta S.p.A. using a simplified analytical model for the prediction of geometry and noncavitating performance of typical space rocket inducers. The transparent inlet section of the facility was instrumented with several piezoelectric pressure transducers located at three axial stations: inducer inlet, outlet and the middle of the axial chord of the blades. At each axial station at least two transducers were mounted with given angular spacing in order to cross-correlate their signals for amplitude, phase and coherence analysis. However, probably because of the high value of the blade tip clearance, very few flow instabilities have been detected on the inducer, including: steady asymmetric cavitation caused by the different extension of the cavitating regions on the blades; cavitation surge at a frequency equal to 0.16 times the inducer rotational frequency; a higher-order axial phenomenon at 7.2 times the rotational frequency.http://deepblue.lib.umich.edu/bitstream/2027.42/84278/1/CAV2009-final92.pd

    A promising new ELISA diagnostic test for cattle babesiosis based on Babesia bigemina Apical Membrane Antigen-1.

    Get PDF
    Babesiosis due to Babesia bigemina is a relevant tick‑borne disease, affecting cattle worldwide. Many surface proteins of the pathogen including the Apical Membrane Antigen 1 (AMA‑1) ‑ have been analysed for vaccine and diagnostic purposes. This study focused on B. bigemina AMA‑1 and on its use for the assessment of diagnostic tests. After bioinformatic analyses, AMA‑1 codifying region was amplified and cloned into an expression vector used to induce protein synthesis in Escherichia coli cells. AMA‑1 was purified by affinity chromatography and used to set up the best condition for an ELISA protocol. Bovine field sera positive to B. bigemina were used to evaluate the presence of anti‑AMA‑1 antibodies. In order to verify the assay specificity, sera positive to Babesia bovis or to the piroplasm Theileria annulata were also included. Significant differences were obtained between sera negative to both B. bigemina and B. bovis and samples positive to B. bigemina, to B. bovis or to both pathogens. No significant reaction was observed with T. annulata positive sera. The results showed that AMA‑1 protein is suitable to be used as antigen in diagnostic assays for babesiosis diagnosis in cattle, as it does not show any cross reaction with anti-T. annulata antibodies

    An overview of the EXTraS project: Exploring the X-ray Transient and Variable Sky

    Full text link
    The EXTraS project (Exploring the X-ray Transient and variable Sky) will harvest the hitherto unexplored temporal domain information buried in the serendipitous data collected by the European Photon Imaging Camera (EPIC) instrument onboard the ESA XMM-Newton X-ray observatory since its launch. This will include a search for fast transients, as well as a search and characterization of variability (both periodic and aperiodic) in hundreds of thousands of sources spanning more than nine orders of magnitude in time scale and six orders of magnitude in flux. X-ray results will be complemented by multiwavelength characterization of new discoveries. Phenomenological classification of variable sources will also be performed. All our results will be made available to the community. A didactic program in selected High Schools in Italy, Germany and the UK will also be implemented. The EXTraS project (2014-2016), funded within the EU/FP7 framework, is carried out by a collaboration including INAF (Italy), IUSS (Italy), CNR/IMATI (Italy), University of Leicester (UK), MPE (Germany) and ECAP (Germany).Comment: 6 pages, 1 figure. Proceedings of "Swift: 10 years of Discovery", to appear in Po
    • …
    corecore