15 research outputs found
Erosive cola-based drinks affect the bonding to enamel surface: an in vitro study
Objective: This study aimed to assess the impact of in vitro erosion provoked by different cola-based drinks (Coke types), associated or not with toothbrushing, to bonding to enamel. Material and methods: Forty-six bovine enamel specimens were prepared and randomly assigned into seven groups (N=8): C- Control (neither eroded nor abraded), ERO-RC: 3x/1-minute immersion in Regular Coke (RC), ERO-LC: 3x/1-minute immersion in Light Coke (LC), ERO-ZC: 3x/1-minute immersion in Zero Coke (ZC) and three other eroded groups, subsequently abraded for 1-minute toothbrushing (EROAB-RC, EROAB-LC and EROAB-ZC, respectively). After challenges, they were stored overnight in artificial saliva for a total of 24 hours and restored with Adper Single Bond 2/Filtek Z350. Buildup coronal surfaces were cut in 1 mm2 -specimens and subjected to a microtensile test. Data were statistically analyzed by two-way ANOVA/Bonferroni tests (α=0.05). Failure modes were assessed by optical microscopy (X40). The Interface of the restorations were observed using Confocal Laser Scanning Microscopy (CLSM). Results: All tested cola-based drinks significantly reduced the bond strength, which was also observed in the analyses of interfaces. Toothbrushing did not have any impact on the bond strength. CLSM showed that except for Zero Coke, all eroded specimens resulted in irregular hybrid layer formation. Conclusions: All cola-based drinks reduced the bond strength. Different patterns of hybrid layers were obtained revealing their impact, except for ZC
Effect of resin-modified glass-ionomer cement lining and composite layering technique on the adhesive interface of lateral wall
Interface integrity can be maintained by setting the composite in a layering technique and using liners. Objective The aim of this in vitro study was to verify the effect of resin-modified glass-ionomer cement (RMGIC) lining and composite layering technique on the bond strength of the dentin/resin adhesive interface of lateral walls of occlusal restorations. Material and Methods Occlusal cavities were prepared in 52 extracted sound human molars, randomly assigned into 4 groups: Group 2H (control) â no lining + two horizontal layers; Group 4O: no lining + four oblique layers; Group V-2H: RMGIC lining (Vitrebond) + two horizontal layers; and Group V-4O: RMGIC lining (Vitrebond) + four oblique layers. Resin composite (Filtek Z250, 3M ESPE) was placed after application of an adhesive system (Adperâą Single Bond 2, 3M ESPE) dyed with a fluorescent reagent (Rhodamine B) to allow confocal microscopy analysis. The teeth were stored in deionized water at 37oC for 24 hours before being sectioned into 0.8 mm slices. One slice of each tooth was randomly selected for Confocal Laser Scanning Microscopy (CLSM) analysis. The other slices were sectioned into 0.8 mm x 0.8 mm sticks to microtensile bond strength test (MPa). Data were analyzed by two-way ANOVA and Fisher's test. Results There was no statistical difference on bond strength among groups (p>0.05). CLSM analysis showed no significant statistical difference regarding the presence of gap at the interface dentin/resin among groups. Conclusions RMGIC lining and composite layering techniques showed no effect on the microtensile bond strength and gap formation at the adhesive interface of lateral walls of high C-factor occlusal restorations
Bond Strength and Interfacial Micromorphology of Etch-and-Rinse and Self-Adhesive Resin Cements to Dentin
Conselho Nacional de Desenvolvimento CientĂfico e TecnolĂłgico (CNPq)Purpose: To evaluate the microtensile bond strength and interfacial micromorphology of indirect composite restorations to dentin using three commercial resin cements after 24 hours and 30 days of water storage. Materials and Methods: The medium dentin of third human molars was exposed (N = 30, n = 10 per group). Three commercial resin cements were used to cement indirect resin composite restorations to dentin: the auto-cured C& B Cement/All Bond 2, the dual-cured RelyX ARC/Adper Single Bond 2, and the self-adhesive dualcured RelyX Unicem. Teeth were sectioned after water storage at 37 degrees C (24 hours and 30 days) to obtain beams with a bonded area of 0.8 mm(2). The specimens were tested in a universal testing machine at a 0.5 mm/min crosshead speed. Scanning electron microscopic fractographic and interfacial micromorphology analyses were performed. Data were analyzed using two-way ANOVA and Tukey's test (alpha = 0.05). Results: Mean bond strength (MPa) after 24 hours: C& B Cement 19.5 +/- 3.8, RelyX ARC 40.8 +/- 9.4, RelyX Unicem 31.3 +/- 7.4; after 30 days: C& B Cement 24.5 +/- 5.1, RelyX ARC 44.2 +/- 8.5, RelyX Unicem 28.3 +/- 7.1. The mean bond strengths of both dual-cure cements were significantly higher than that obtained with C& B Cement after 24 hours. A significant increase in the bond strength of C& B Cement was verified after 30 days, reaching values statistically equivalent to those produced by RelyX Unicem and RelyX ARC. The self-adhesive cement preserved the same level of bond strength after 30 days. Fractographic analysis revealed a prevalence of cohesive fractures in the hybrid layer for C& B Cement, mixed (cohesive in the cement, hybrid layer, and adhesive) for RelyX ARC, and cohesive in the cement for RelyX Unicem. No distinguishable hybrid layer or resin tags were observed in the interaction of RelyX Unicem with dentin. Conclusions: The particular interaction of each cement with dentin results in specific bond strength and failure patterns that varied among groups in both evaluation times. Even though the self-adhesive cement tested exhibited no authentic hybrid layer, it was able to promote reliable adhesion with the underlying dentin.212101111Conselho Nacional de Desenvolvimento CientĂfico e TecnolĂłgico (CNPq)Conselho Nacional de Desenvolvimento CientĂfico e TecnolĂłgico (CNPq)CNPq [310845/2006-8
Micro-sized erosions in a nanofilled composite after repeated acidic beverage exposures: consequences of clusters dislodgments
Objective: To evaluate the hardness (KHN), color stability (DE), and superficial micromorphology of two categories of composites after immersion in either distilled water or grape juice for up to 45 days. MATERIAL AND METHODS: Cylindrical specimens (6 mm diameter x 2 mm thick) were obtained according to the factors: composite [Opallis (FGM) and Filtek Z350XT (3M ESPE)]; immersion solution (distilled water and grape juice); and evaluation time: 24 h and 7, 14, 21, 28, and 45 days. After photoactivation, the specimens were stored at 37ÂșC for 24 h. KHN (50 g/15 s) and ÎE were then repeatedly assessed according to the immersion solutions. Data were analyzed (three-way ANOVA/Tukey's test). Scanning electron microscopy (SEM) topographic analysis was also performed. RESULTS: In general, KHN of both composites reduced after 24 h, irrespective of the immersion solution and time. A significantly lower KHN was noted for Opallis compared with Filtek Z350XT in all parameters. An increase in ÎE over time was noted for both composites, irrespective of the immersion solution. Significantly higher ÎE was noted for Filtek Z350XT immersed in grape juice compared with Opallis, regardless of the evaluation time. The grape juice caused significantly higher DE compared with water in all periods. SEM analysis showed eroded areas for Filtek Z350XT but not for Opallis. CONCLUSIONS: The compositions and immersion solutions influence the composite hardness and the color stability. In spite of the higher hardness, the nanofilled composite is more susceptible to color change than the microhybrid when immersed in an acidic dyed solution
Water interaction and bond strength to dentin of dye-labelled adhesive as a function of the addition of rhodamine B
ABSTRACT Objective This study investigated the effect of the fluorescent dye rhodamine B (RB) for interfacial micromorphology analysis of dental composite restorations on water sorption/solubility (WS/WSL) and microtensile bond strength to dentin (”TBS) of a 3-step total etch and a 2-step self-etch adhesive system. Material and Methods The adhesives Adper Scotchbond Multi-Purpose (MP) and Clearfil SE Bond (SE) were mixed with 0.1 mg/mL of RB. For the WS/WSL tests, cured resin disks (5.0 mm in diameter x 0.8 mm thick) were prepared and assigned into four groups (n=10): MP, MP-RB, SE, and SE-RB. For ”TBS assessment, extracted human third molars (n=40) had the flat occlusal dentin prepared and assigned into the same experimental groups (n=10). After the bonding and restoration procedures, specimens were sectioned in rectangular beams, stored in water and tested after seven days or after 12 months. The failure mode of fractured specimens was qualitatively evaluated under optical microscope (x40). Data from WS/WSL and ”TBS were assessed by one-way and three-way ANOVA, respectively, and Tukey’s test (α=5%). Results RB increased the WSL of MP and SE. On the other hand, WS of both MP and SE was not affected by the addition of RB. No significance in ”TBS between MP and MP-RB for seven days or one year was observed, whereas for SE a decrease in the ”TBS means occurred in both storage times. Conclusions RB should be incorporated into non-simplified DBSs with caution, as it can interfere with their physical-mechanical properties, leading to a possible misinterpretation of bonded interface