591 research outputs found

    The value of source data verification in a cancer clinical trial

    Get PDF
    Background Source data verification (SDV) is a resource intensive method of quality assurance frequently used in clinical trials. There is no empirical evidence to suggest that SDV would impact on comparative treatment effect results from a clinical trial. Methods Data discrepancies and comparative treatment effects obtained following 100% SDV were compared to those based on data without SDV. Overall survival (OS) and Progression-free survival (PFS) were compared using Kaplan-Meier curves, log-rank tests and Cox models. Tumour response classifications and comparative treatment Odds Ratios (ORs) for the outcome objective response rate, and number of Serious Adverse Events (SAEs) were compared. OS estimates based on SDV data were compared against estimates obtained from centrally monitored data. Findings Data discrepancies were identified between different monitoring procedures for the majority of variables examined, with some variation in discrepancy rates. There were no systematic patterns to discrepancies and their impact was negligible on OS, the primary outcome of the trial (HR (95% CI): 1.18(0.99 to 1.41), p = 0.064 with 100% SDV; 1.18(0.99 to 1.42), p = 0.068 without SDV; 1.18(0.99 to 1.40), p = 0.073 with central monitoring). Results were similar for PFS. More extreme discrepancies were found for the subjective outcome overall objective response (OR (95% CI): 1.67(1.04 to 2.68), p = 0.03 with 100% SDV; 2.45(1.49 to 4.04), p = 0.0003 without any SDV) which was mostly due to differing CT scans. Interpretation Quality assurance methods used in clinical trials should be informed by empirical evidence. In this empirical comparison, SDV was expensive and identified random errors that made little impact on results and clinical conclusions of the trial. Central monitoring using an external data source was a more efficient approach for the primary outcome of OS. For the subjective outcome objective response, an independent blinded review committee and tracking system to monitor missing scan data could be more efficient than SDV

    Biomechanical effects of polyaxial pedicle screw fixation on the lumbosacral segments with an anterior interbody cage support

    Get PDF
    BACKGROUND: Lumbosacral fusion is a relatively common procedure that is used in the management of an unstable spine. The anterior interbody cage has been involved to enhance the stability of a pedicle screw construct used at the lumbosacral junction. Biomechanical differences between polyaxial and monoaxial pedicle screws linked with various rod contours were investigated to analyze the respective effects on overall construct stiffness, cage strain, rod strain, and contact ratios at the vertebra-cage junction. METHODS: A synthetic model composed of two ultrahigh molecular weight polyethylene blocks was used with four titanium pedicle screws (two in each block) and two rods fixation to build the spinal construct along with an anterior interbody cage support. For each pair of the construct fixed with polyaxial or monoaxial screws, the linked rods were set at four configurations to simulate 0°, 7°, 14°, and 21° lordosis on the sagittal plane, and a compressive load of 300 N was applied. Strain gauges were attached to the posterior surface of the cage and to the central area of the left connecting rod. Also, the contact area between the block and the cage was measured using prescale Fuji super low pressure film for compression, flexion, lateral bending and torsion tests. RESULTS: Our main findings in the experiments with an anterior interbody cage support are as follows: 1) large segmental lordosis can decrease the stiffness of monoaxial pedicle screws constructs; 2) polyaxial screws rather than monoaxial screws combined with the cage fixation provide higher compression and flexion stiffness in 21° segmental lordosis; 3) polyaxial screws enhance the contact surface of the cage in 21° segmental lordosis. CONCLUSION: Polyaxial screws system used in conjunction with anterior cage support yields higher contact ratio, compression and flexion stiffness of spinal constructs than monoaxial screws system does in the same model when the spinal segment is set at large lordotic angles. Polyaxial pedicle screw fixation performs nearly equal percentages of vertebra-cage contact among all constructs with different sagittal alignments, therefore enhances the stabilization effect of interbody cages in the lumbosacral area

    Core components for effective infection prevention and control programmes: new WHO evidence-based recommendations

    Get PDF
    Abstract Health care-associated infections (HAI) are a major public health problem with a significant impact on morbidity, mortality and quality of life. They represent also an important economic burden to health systems worldwide. However, a large proportion of HAI are preventable through effective infection prevention and control (IPC) measures. Improvements in IPC at the national and facility level are critical for the successful containment of antimicrobial resistance and the prevention of HAI, including outbreaks of highly transmissible diseases through high quality care within the context of universal health coverage. Given the limited availability of IPC evidence-based guidance and standards, the World Health Organization (WHO) decided to prioritize the development of global recommendations on the core components of effective IPC programmes both at the national and acute health care facility level, based on systematic literature reviews and expert consensus. The aim of the guideline development process was to identify the evidence and evaluate its quality, consider patient values and preferences, resource implications, and the feasibility and acceptability of the recommendations. As a result, 11 recommendations and three good practice statements are presented here, including a summary of the supporting evidence, and form the substance of a new WHO IPC guideline

    Clinical report of cervical arthroplasty in management of spondylotic myelopathy in Chinese

    Get PDF
    OBJECTIVES: To investigate clinical effects and manual operational point of Bryan cervical disc prosthesis in Chinese, to observe the stability and range of movement (ROM) post-operatively. METHODS AND MATERIALS: From 2003,12 to 2005,12, Bryan disc prosthesis replacement applied in 83 cases (102 levels) of cervical spondylotic myelopathy (CSM) after anterior decompression in our hospital. Clinical (JOA grade and Odom's scale) and radiological (X-ray of flexion, extension; left and right bending position) follow-up was performed. Systemic radiographic study about stability and ROM of replaced level post operationally were measured. CT or MRI scans were applied in all cases to evaluate the signs of the prosthesis deflexion and hetero-ossification in the replaced levels. RESULTS: At least 12 months follow-up were done in 65/83 of these paients. All of 83 patients were improved according to Odsm's scale. JOA score increased from average 8.7 to 15.5. There was no prosthesis subsidence. Replaced segment achieved stability and restored partial of normal ROM 4.73°(3.7°–5.9°) early postoperation and 8.12°(5.8°–13.6°) more than 12 months postoperation in flex and extension position. No obvious loss of lordosis was found. CT or MRI follow-up shows position deflexion of the prosthesis metal endplates (<1.5 mm) in 14/77 levels and (1.5~3 mm) in 4/77. heter-ossification was found in the replaced levels only in 2 cases. CONCLUSION: Byran cervical disc prosthesis restored motion to the level of the intact segment in flexion-extension and lateral bending in post-operative images. At the same time, it can achieve good anterior decompression treatment effect and immediate stability in replaced 1 or 2 levels, and which is a new choice for the treatment of CSM

    Am I getting an accurate picture: a tool to assess clinical handover in remote settings?

    Get PDF
    BACKGROUND: Good clinical handover is critical to safe medical care. Little research has investigated handover in rural settings. In a remote setting where nurses and medical students give telephone handover to an aeromedical retrieval service, we developed a tool by which the receiving clinician might assess the handover; and investigated factors impacting on the reliability and validity of that assessment. METHODS: Researchers consulted with clinicians to develop an assessment tool, based on the ISBAR handover framework, combining validity evidence and the existing literature. The tool was applied 'live' by receiving clinicians and from recorded handovers by academic assessors. The tool's performance was analysed using generalisability theory. Receiving clinicians and assessors provided feedback. RESULTS: Reliability for assessing a call was good (G = 0.73 with 4 assessments). The scale had a single factor structure with good internal consistency (Cronbach's alpha = 0.8). The group mean for the global score for nurses and students was 2.30 (SD 0.85) out of a maximum 3.0, with no difference between these sub-groups. CONCLUSIONS: We have developed and evaluated a tool to assess high-stakes handover in a remote setting. It showed good reliability and was easy for working clinicians to use. Further investigation and use is warranted beyond this setting

    Complications and reoperations of the SB Charité lumbar disc prosthesis: experience in 75 patients

    Get PDF
    Artificial disc prosthesis show fair to good short- and mid-term results. Long-term results are becoming apparent now, however, the incidence of late complications with this procedure remain poorly understood. In this report we will analyse late complications and discuss our experiences with salvage operations in patients with persistent pain after SB Charité disc prosthesis implantation. Seventy-five patients with persistent leg and back pain after insertion of an artificial disc prosthesis were enrolled in the study. In this negative selection frequently occurring late-complications were subsidence, wear, adjacent disc degeneration, facet joint degeneration and migration. In 15 patients we performed a posterior fusion without disc removal, and in 22 patients we removed 26 prostheses and performed a posterior and anterior fusion. The visual analogue scale (VAS) and Oswestry were examined before the salvage operation and after a follow-up period of at least 1 year, which is not yet available in all patients. The VAS and Oswestry decreased in the posterior group (n = 10) respectively from 8.0 (SD 0.9) to 6.3 (SD 2.1) and from 57.0 (SD 17.0) to 44.6 (SD 20.4); and in the disc removal group (n = 14) respectively from 8.0 (SD 0.9) to 5.6 (SD 2.7) and from 56.3 (SD 14.0) to 43.0 (SD 20.7). Serious late complications may occur following total disc replacement. Removal of the SB Charité artificial disc is feasible but with inherent risks. Removal of the disc prosthesis gives slightly better results than posterior fusion alone after a follow-up of at least 1 year

    Effective Reduced Diffusion-Models: A Data Driven Approach to the Analysis of Neuronal Dynamics

    Get PDF
    We introduce in this paper a new method for reducing neurodynamical data to an effective diffusion equation, either experimentally or using simulations of biophysically detailed models. The dimensionality of the data is first reduced to the first principal component, and then fitted by the stationary solution of a mean-field-like one-dimensional Langevin equation, which describes the motion of a Brownian particle in a potential. The advantage of such description is that the stationary probability density of the dynamical variable can be easily derived. We applied this method to the analysis of cortical network dynamics during up and down states in an anesthetized animal. During deep anesthesia, intracellularly recorded up and down states transitions occurred with high regularity and could not be adequately described by a one-dimensional diffusion equation. Under lighter anesthesia, however, the distributions of the times spent in the up and down states were better fitted by such a model, suggesting a role for noise in determining the time spent in a particular state

    Postoperative spinal infection mimicking systemic vasculitis with titanium-spinal implants

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Secondary systemic vasculitis after posterior spinal fusion surgery is rare. It is usually related to over-reaction of immune-system, to genetic factors, toxicity, infection or metal allergies.</p> <p>Case Description</p> <p>A 14 year-old girl with a history of extended posterior spinal fusion due to idiopathic scoliosis presented to our department with diffuse erythema and nephritis (macroscopic hemuresis and proteinuria) 5 months post surgery. The surgical trauma had no signs of inflammation or infection. The blood markers ESR and CRP were increased. Skin tests were positive for nickel allergy, which is a content of titanium alloy. The patient received corticosteroids systematically (hydrocortisone 10 mg) for 6 months, leading to total recess of skin and systemic reaction. However, a palpable mass close to the surgical wound raised the suspicion of a late infection. The patient had a second surgery consisting of surgical debridement and one stage revision of posterior spinal instrumentation. Intraoperative cultures were positive to Staphylococcus aureus. Intravenous antibiotics were administered. The patient is now free of symptoms 24 months post revision surgery without any signs of recurrence of either vasculitis or infection.</p> <p>Literature Review</p> <p>Systemic vasculitis after spinal surgery is exceptionally rare. Causative factors are broad and sometimes controversial. In general, it is associated with allergy to metal ions. This is usually addressed with metal on metal total hip bearings. In spinal surgery, titanium implants are considered to be inert and only few reports have presented cases with systemic vasculitides. Therefore, other etiologies of immune over-reaction should always be considered, such as drug toxicity, infection, or genetic predisposition.</p> <p>Purposes and Clinical Relevance</p> <p>Our purpose was to highlight the difficulties during the diagnostic work-up for systemic vasculitis and management in cases of posterior spinal surgery.</p

    Nicotinic Acetylcholine Receptor Variants Are Related to Smoking Habits, but Not Directly to COPD

    Get PDF
    Genome-wide association studies identified single nucleotide polymorphisms (SNPs) in the nicotinic acetylcholine receptors (nAChRs) cluster as a risk factor for nicotine dependency and COPD. We investigated whether SNPs in the nAChR cluster are associated with smoking habits and lung function decline, and if these potential associations are independent of each other. The SNPs rs569207, rs1051730 and rs8034191 in the nAChR cluster were analyzed in the Vlagtwedde-Vlaardingen cohort (n = 1,390) that was followed for 25 years. We used GEE and LME models to analyze the associations of the SNPs with quitting or restarting smoking and with the annual FEV1 decline respectively. Individuals homozygote (CC) for rs569207 were more likely to quit smoking (OR (95%CI) = 1.58 (1.05–2.38)) compared to wild-type (TT) individuals. Individuals homozygote (TT) for rs1051730 were less likely to quit smoking (0.64 (0.42; 0.97)) compared to wild-type (CC) individuals. None of the SNPs was significantly associated with the annual FEV1 decline in smokers and ex-smokers. We show that SNPs in the nAChR region are associated with smoking habits such as quitting smoking, but have no significant effect on the annual FEV1 decline in smokers and ex-smokers, suggesting a potential role of these SNPs in COPD development via smoking habits rather than via direct effects on lung function
    corecore