191 research outputs found

    Evidence of Color Coherence Effects in W+jets Events from ppbar Collisions at sqrt(s) = 1.8 TeV

    Full text link
    We report the results of a study of color coherence effects in ppbar collisions based on data collected by the D0 detector during the 1994-1995 run of the Fermilab Tevatron Collider, at a center of mass energy sqrt(s) = 1.8 TeV. Initial-to-final state color interference effects are studied by examining particle distribution patterns in events with a W boson and at least one jet. The data are compared to Monte Carlo simulations with different color coherence implementations and to an analytic modified-leading-logarithm perturbative calculation based on the local parton-hadron duality hypothesis.Comment: 13 pages, 6 figures. Submitted to Physics Letters

    Fast-timing measurements in neutron-rich odd-mass zirconium isotopes using LaBr3:Ce detectors coupled with Gammasphere

    Get PDF
    A fast-timing experiment was performed at the Argonne National Laboratory to measure the lifetimes of the lowest lying states of nuclei belonging to the deformed regions around mass number A 110 and A 150. These regions were populated via spontaneous fission of 252 Cf and the gamma radiation following the decay of excited states in the fission fragments was measured using 51 Gammasphere detectors coupled with 25 LaBr 3 :Ce detectors. A brief description of the acquisition system and some preliminary results from the fast-timing analysis of the fission fragment 100Zr are presented. The lifetime value of \u3c4 = 840(65) ps was found for the 2 + state in 100 Zr consistent within one standard deviation of the adopted value with 791 +26 -35 ps. This is associated with a quadrupole deformation parameter of 0.36(2) which is within one standard deviation of the literature value of 0.3556 +82 -57

    Fast-timing measurements in the ground-state band of Pd114

    Get PDF
    Using a hybrid Gammasphere array coupled to 25 LaBr3(Ce) detectors, the lifetimes of the first three levels of the yrast band in Pd-114, populated via Cf-252 decay, have been measured. The measured lifetimes are tau(2+) = 103(10) ps, tau(4+) = 22(13) ps, and tau(6+) <= 10 ps for the 2(1)(+), 4(1)(+), and 6(1)(+) levels, respectively. Palladium-114 was predicted to be the most deformed isotope of its isotopic chain, and spectroscopic studies have suggested it might also be a candidate nucleus for low-spin stable triaxiality. From the lifetimes measured in this work, reduced transition probabilities B(E2; J -> J - 2) are calculated and compared with interacting boson model, projected shell model, and collective model calculations from the literature. The experimental ratio R-B(E2) = B(E2; 4(1)(+) -> 2(1)(+))/B(E2; 2(1)(+) -> 0(1)(+)) = 0.80(42) is measured for the first time in Pd-114 and compared with the known values R-B(E2) in the palladium isotopic chain: the systematics suggest that, for N = 68, a transition from gamma-unstable to a more rigid gamma-deformed nuclear shape occurs

    Dynamic Assessment of Baroreflex Control of Heart Rate During Induction of Propofol Anesthesia Using a Point Process Method

    Get PDF
    In this article, we present a point process method to assess dynamic baroreflex sensitivity (BRS) by estimating the baroreflex gain as focal component of a simplified closed-loop model of the cardiovascular system. Specifically, an inverse Gaussian probability distribution is used to model the heartbeat interval, whereas the instantaneous mean is identified by linear and bilinear bivariate regressions on both the previous R−R intervals (RR) and blood pressure (BP) beat-to-beat measures. The instantaneous baroreflex gain is estimated as the feedback branch of the loop with a point-process filter, while the RRBP feedforward transfer function representing heart contractility and vasculature effects is simultaneously estimated by a recursive least-squares filter. These two closed-loop gains provide a direct assessment of baroreflex control of heart rate (HR). In addition, the dynamic coherence, cross bispectrum, and their power ratio can also be estimated. All statistical indices provide a valuable quantitative assessment of the interaction between heartbeat dynamics and hemodynamics. To illustrate the application, we have applied the proposed point process model to experimental recordings from 11 healthy subjects in order to monitor cardiovascular regulation under propofol anesthesia. We present quantitative results during transient periods, as well as statistical analyses on steady-state epochs before and after propofol administration. Our findings validate the ability of the algorithm to provide a reliable and fast-tracking assessment of BRS, and show a clear overall reduction in baroreflex gain from the baseline period to the start of propofol anesthesia, confirming that instantaneous evaluation of arterial baroreflex control of HR may yield important implications in clinical practice, particularly during anesthesia and in postoperative care.National Institutes of Health (U.S.) (Grant R01-HL084502)National Institutes of Health (U.S.) (Grant K25-NS05758)National Institutes of Health (U.S.) (Grant DP2- OD006454)National Institutes of Health (U.S.) (Grant T32NS048005)National Institutes of Health (U.S.) (Grant T32NS048005)National Institutes of Health (U.S.) (Grant R01-DA015644)Massachusetts General Hospital (Clinical Research Center, UL1 Grant RR025758

    Diagnosis of biliary tract and ampullary carcinomas

    Get PDF
    Diagnostic methods for biliary tract carcinoma and the efficacy of these methods are discussed. Neither definite methods for early diagnosis nor specific markers are available in this disease. When this disease is suspected on the basis of clinical symptoms and risk factors, hemato-biochemical examination and abdominal ultrasonography are performed and, where appropriate, enhanced computed tomography (CT) and/or magnetic resonance cholangiopancreatography (MRCP) is carried out. Diagnoses of extrahepatic bile duct cancer and ampullary carcinoma are often made based on the presence of obstructive jaundice. Although rare, abdominal pain and pyrexia, as well as abnormal findings of the hepatobiliary system detected by hemato-biochemical examination, serve as a clue to making a diagnosis of these diseases. On the other hand, the early diagnosis of gallbladder cancer is scarcely possible on the basis of clinical symptoms, so when this cancer is found with the onset of abdominal pain and jaundice, it is already advanced at the time of detection, thus making a cure difficult. When gallbladder cancer is suspected, enhanced CT is carried out. Multidetector computed tomography (MDCT), in particular — one of the methods of enhanced CT — is useful for decision of surgical criteria, because MDCT shows findings such as localization and extension of the tumor, and the presence or absence of remote metastasis. Procedures such as magnetic resonance imaging, endoscopic ultrasonography, bile duct biopsy, and cholangioscopy should be carried out taking into account indications for these procedures in individual patients. However, direct biliary tract imaging is necessary for making a precise diagnosis of the horizontal extension of bile duct cancer

    Fast-timing measurements in the ground-state band of Pd 114

    Get PDF
    Using a hybrid Gammasphere array coupled to 25 LaBr3(Ce) detectors, the lifetimes of the first three levels of the yrast band in Pd114, populated via Cf252 decay, have been measured. The measured lifetimes are τ2+=103(10)ps, τ4+=22(13)ps, and τ6+≤10ps for the 21+, 41+, and 61+ levels, respectively. Palladium-114 was predicted to be the most deformed isotope of its isotopic chain, and spectroscopic studies have suggested it might also be a candidate nucleus for low-spin stable triaxiality. From the lifetimes measured in this work, reduced transition probabilities B(E2;J→J-2) are calculated and compared with interacting boson model, projected shell model, and collective model calculations from the literature. The experimental ratio RB(E2)=B(E2;41+→21+)/B(E2;21+→01+)=0.80(42) is measured for the first time in Pd114 and compared with the known values RB(E2) in the palladium isotopic chain: the systematics suggest that, for N=68, a transition from γ-unstable to a more rigid γ-deformed nuclear shape occurs

    Fast-Timing measurements in 100zr using labr3(ce) detectors coupled with gammasphere

    Get PDF
    In order to investigate the evolution of nuclear deformation in the region of the chart of nuclides around mass numbers A ' 110 and A ' 150, an experiment was performed at the Argonne National Laboratory where the gamma-decay radiation emitted from the fission fragments of 252Cf was measured using 51 Gammasphere detectors coupled with 25 LaBr3(Ce) detectors. In this work, a short description of the experimental setup is presented together with some preliminary results from the fast-Timing analysis of the 4+ state of the nucleus 100Zr. A lifetime value of τ = 50(28) ps was obtained using the Generalized Centroid Shift Method. This result agrees with the literature value of τ = 53(4) ps within one standard deviation

    Fast timing measurement using an labr3(Ce) scintillator detector array coupled with gammasphere

    Get PDF
    A fast-timing experiment was performed at the Argonne National Laboratory in December 2015 and January 2016, measuring decay radiation of fission products from a 252Cf fission source. Details of the set-up, integration with Digital Gammasphere, and the data acquisition system are presented. The timing performance of the set-up, capable of measuring lifetimes from the nanosecond region down to tens of picoseconds, is discussed. First preliminary results from the fast-timing analysis of the fission fragment data are presented
    corecore