618 research outputs found

    Registro nacional de pacientes intervenidos de cirugĂ­a cardiovascular («QUIP-ESPAÑA»)

    Get PDF

    Design tool to predict the open-hole failure strength of composite laminates subjected to in-plane loads

    Get PDF
    A design tool based on Whitney-Nuismer model is proposed to predict the failure strength of open-hole composite plates subjected to in-plane loads, both tensile and compressive. One of the limitations of this model is the use of characteristic distances, which have to be estimated, and which are mostly considered constant material properties. In this work, it is demonstrated that these characteristic distances are a function of the plate geometry and are not a material property. Different analytical expressions are proposed to estimate the characteristic distances by using the results of only three experimental tests. This approach enables an accurate and fast estimation of the failure strength when the parameters of the plate are modified without using numerical simulations that require a longer time to be carried out.The authors are indebted for the financial support of this work to the Ministry of Economy and Finance of Spain (project DPI2013-42240-R).Publicad

    Status of the Optical Multiplexer Board 9U Prototype

    Get PDF
    This paper presents the architecture and the status of the Optical Multiplexer Board (OMB) 9U for the ATLAS/LHC Tile hadronic calorimeter (TileCal). This board will analyze the front-end data CRC to prevent bit and burst errors produced by radiation. Besides, due to its position within the data acquisition chain it will be used to emulate front-end data for tests. The first two prototypes of the final OMB 9U version have been produced at CERN. Detailed design issues and manufacture features of these prototypes are described. Functional descriptions of the board on its two main operation modes as CRC checking and data ROD injector are explained as well as other functionalities. Finally, the schedule for next year when the production of the OMB will be take place is also presented

    On the development of the final optical multiplexer board prototype for the TileCal experiment

    Get PDF
    This paper describes the architecture of the final optical multiplexer board for the TileCal experiment. The results of the first VME 6U prototype have led to the definition of the final block diagram and functionality of this prototype. Functional description of constituent blocks and the state of the work currently undergoing at the Department of Electronic Engineering, in collaboration with IFIC-Valencia, is presented. As no board is yet produced, no experimental results are presented but, nevertheless, design issues that have been taking into account as component placement and signal integrity issues will be detailed

    Indexed left atrial size predicts all-cause and cardiovascular mortality in patients undergoing aortic valve surgery

    Get PDF
    [Abstract] OBJECTIVES: The enlargement of the left atrium has been identified as a marker of chronically increased left ventricular filling pressure and left ventricular diastolic dysfunction. This study aims to evaluate the association of indexed left atrial diameter with stroke, cardiovascular mortality, the combined event, and all-cause mortality in patients who underwent aortic valve surgery. METHODS: Indexed left atrial diameter was measured in 2011 adult patients (mean age, 70.9 ± 10.8 years; 58.7% were men) who underwent aortic valve surgery between January 2008 and March 2016. RESULTS: On the basis of the criteria of the American Society of Echocardiography, indexed left atrial diameter was normal in 64% of patients, mildly enlarged in 12.4% of patients, moderately enlarged in 9.2% of patients, and severely enlarged in 14.3% of patients. Over a mean follow-up period of 3.2 ± 2.1 years, there were 334 deaths and 97 strokes. Cardiovascular mortality survival at 5 years among patients with normal, mild, moderate, and severe left atrial enlargement was 91.6%, 86.8%, 77.9%, and 77.4%, respectively (P < .001). After covariable adjustment, Cox regression analysis showed indexed left atrial diameter as an independent predictor of all-cause mortality (hazard ratio per 1-cm/m2 increment, 1.545; 95% confidence interval, 1.252-1.906, P < .001), cardiovascular death (hazard ratio per 1-cm/m2 increment, 1.971; 95% confidence interval, 1.541-2.520; P < .001), and the combined event (hazard ratio per 1-cm/m2 increment, 1.673; 95% confidence interval, 1.321-2.119; P < .001). CONCLUSIONS: Indexed left atrial diameter is a strong predictor of long-term outcomes in patients with aortic valve diseases who undergo surgery

    A Complete Set of Firmware for the TileCal Read-Out Driver

    Get PDF
    TileCal is the hadronic tile calorimeter of the ATLAS experiment at LHC/CERN. The Read-Out Driver (ROD) is the main component of the TileCal back-end electronics. The ROD is a VME 64x 9u board with multiple programmable devices which requires a complete set of firmware. This paper describes the firmware and functionalities of all these programmable devices, especially the DSP Processing Units daughterboards where the data processing takes place

    Optical Buffer 1:16

    Get PDF
    This document is a manual describing the functionality and the operation of the Optical Buffer 1:16 (OB). The OB was specially designed to repeat optical signals during the TileCal Read-Out drivers (ROD) production. The data generated in one Optical Multiplexer Board (OMB) 6U prototypes were repeated with two OB in order to inject data simultaneously to four RODs
    • 

    corecore