12 research outputs found

    Fístulas coronarias congénitas, un reto en el manejo terapéutico

    Get PDF
    Congenital coronary fistulas are uncommon vascular anomalies. They typically progress asymptomatically andare identified in the evaluation a heart murmur. Clinical follow-up and multimodal imaging are crucial for establishing appropriate management for each case. We present a patient who has been followed 25 years of followup for multiple coronary fistulas with significant left-to-left shunting, leading to left ventricular dilation that physiopathologically mimics severe aortic regurgitation. Therapeutic management will depend on clinical evolutionand the anatomical feasibility of closing the fistulous pathways.Las fístulas coronarias congénitas son anomalías vasculares poco comunes. Generalmente son asintomáticas y se diagnostican en el estudio de un soplo cardíaco. El seguimiento clínico y por imagen multimodal es esencial para establecer un manejo adecuado para cada paciente. Presentamos el caso de un varón que lleva 25 de años de seguimiento por múltiples fístulas coronarias con un importante cortocircuito izquierda-izquierda que ha causado una dilatación ventricular izquierda con una fisiopatología similar al de una insuficiencia aórtica severa. El manejo terapéutico dependerá de la evolución clínica y de la factibilidad anatómica para realizar el cierre de los trayectos fistulosos

    The valve uptake index: improving assessment of prosthetic valve endocarditis and updating [18F]FDG PET/CT(A) imaging criteria

    Get PDF
    Infective endocarditis; Nuclear imaging; Positron emission tomographyEndocarditis infecciosa; Imagen nuclear; Tomografía de emisión de positronesEndocarditis infecciosa; Imatge nuclear; Tomografia per emissió de positronsAims Diagnosis of prosthetic valve endocarditis (PVE) by positron emission computed tomography angiography (PET/CTA) is based on visual and quantitative morpho-metabolic features. However, the fluorodeoxyglucose (FDG) uptake pattern can be sometimes visually unclear and susceptible to subjectivity. This study aimed to validate a new parameter, the valve uptake index [VUI, maximum standardized uptake value (SUVmax)−mean standardized uptake value (SUVmean)/SUVmax], designed to provide a more objective indication of the distribution of metabolic activity. Secondly, to re-evaluate the utility of traditionally used PVE imaging criteria and determine the potential value of adding the VUI in the diagnostic algorithm of PVE. Methods and results Retrospective analysis of 122 patients (135 prosthetic valves) admitted for suspicion of endocarditis, with a conclusive diagnosis of definite (N = 57) or rejected (N = 65) PVE, and who had undergone a cardiac PET/CTA scan as part of the diagnostic evaluation. We measured the VUI and recorded the SUVmax, SUVratio, uptake pattern, and the presence of endocarditis-related anatomic lesions. The VUI, SUVmax, and SUVratio values were 0.54 ± 0.1 vs. 0.36 ± 0.08, 7.68 ± 3.07 vs. 3.72 ± 1.11, and 4.28 ± 1.93 vs. 2.16 ± 0.95 in the ‘definite’ PVE group vs. the ‘rejected’ group, respectively (mean ± SD; P 0.45 showed a sensitivity, specificity, and diagnostic accuracy for PVE of 85%, 88%, and 86.7% and increased diagnostic ability for confirming endocarditis when combined with the standard diagnostic criteria. Conclusions The VUI demonstrated good diagnostic accuracy for PVE, even increasing the diagnostic power of the traditionally used morphometabolic parameters, which also confirmed their own diagnostic performance. More research is needed to assess whether the integration of the VUI into the PVE diagnostic algorithm may clarify doubtful cases and thus improve the diagnostic yield of PET/CTA

    The valve uptake index : improving assessment of prosthetic valve endocarditis and updating [ 18 F]FDG PET/CT(A) imaging criteria

    Get PDF
    Diagnosis of prosthetic valve endocarditis (PVE) by positron emission computed tomography angiography (PET/CTA) is based on visual and quantitative morpho-metabolic features. However, the fluorodeoxyglucose (FDG) uptake pattern can be sometimes visually unclear and susceptible to subjectivity. This study aimed to validate a new parameter, the valve uptake index [VUI, maximum standardized uptake value (SUVmax)−mean standardized uptake value (SUVmean)/SUVmax], designed to provide a more objective indication of the distribution of metabolic activity. Secondly, to re-evaluate the utility of traditionally used PVE imaging criteria and determine the potential value of adding the VUI in the diagnostic algorithm of PVE. Retrospective analysis of 122 patients (135 prosthetic valves) admitted for suspicion of endocarditis, with a conclusive diagnosis of definite (N = 57) or rejected (N = 65) PVE, and who had undergone a cardiac PET/CTA scan as part of the diagnostic evaluation. We measured the VUI and recorded the SUVmax, SUVratio, uptake pattern, and the presence of endocarditis-related anatomic lesions. The VUI, SUVmax, and SUVratio values were 0.54 ± 0.1 vs. 0.36 ± 0.08, 7.68 ± 3.07 vs. 3.72 ± 1.11, and 4.28 ± 1.93 vs. 2.16 ± 0.95 in the 'definite' PVE group vs. the 'rejected' group, respectively (mean ± SD; P 0.45 showed a sensitivity, specificity, and diagnostic accuracy for PVE of 85%, 88%, and 86.7% and increased diagnostic ability for confirming endocarditis when combined with the standard diagnostic criteria. The VUI demonstrated good diagnostic accuracy for PVE, even increasing the diagnostic power of the traditionally used morphometabolic parameters, which also confirmed their own diagnostic performance. More research is needed to assess whether the integration of the VUI into the PVE diagnostic algorithm may clarify doubtful cases and thus improve the diagnostic yield of PET/CTA

    Predictive Value of Cardiac Magnetic Resonance Feature Tracking after Acute Myocardial Infarction: A Comparison with Dobutamine Stress Echocardiography

    Get PDF
    Ecocardiografía de seguimiento de manchas; Deformación del miocardio; Seguimiento de características de resonancia magnética cardíacaSpeckle-tracking echocardiography; Myocardial deformation; Cardiac magnetic resonance feature-trackingEcocardiografia de seguiment de taques; Deformació del miocardi; Seguiment de característiques de ressonància magnètica cardíacaIn acute ST-segment elevation myocardial infarction (STEMI) late gadolinium enhancement (LGE) may underestimate segmental functional recovery. We evaluated the predictive value of cardiac magnetic resonance (CMR) feature-tracking (FT) for functional recovery and whether it incremented the value of LGE compared to low-dose dobutamine stress echocardiography (LDDSE) and speckle-tracking echocardiography (STE). Eighty patients underwent LDDSE and CMR within 5–7 days after STEMI and segmental functional recovery was defined as improvement in wall-motion at 6-months CMR. Optimal conventional and FT parameters were analyzed and then also applied to an external validation cohort of 222 STEMI patients. Circumferential strain (CS) was the strongest CMR-FT predictor and addition to LGE increased the overall accuracy to 74% and was especially relevant in segments with 50–74% LGE (AUC 0.60 vs. 0.75, p = 0.001). LDDSE increased the overall accuracy to 71%, and in the 50–74% LGE subgroup improved the AUC from 0.60 to 0.69 (p = 0.039). LGE + CS showed similar value as LGE + LDDSE. In the validation cohort, CS was also the strongest CMR-FT predictor of recovery and addition of CS to LGE improved overall accuracy to 73% although this difference was not significant (AUC 0.69, p = 0.44). Conclusion: CS is the strongest CMR-FT predictor of segmental functional recovery after STEMI. Its incremental value to LGE is comparable to that of LDDSE whilst avoiding an inotropic stress agent. CS is especially relevant in segments with 50–74% LGE where accuracy is lower and further testing is frequently required to clarify the potential for recovery.This research was supported by the Instituto de Salud Carlos III and co-funded by Fondo Europeo de Desarrollo Regional (FEDER) (grant numbers PI17/01836 and CIBERCV16/11/00486). JG and DM acknowledge financial support from the “Agencia Valenciana de la Innovación, Generalitat Valenciana” (grant) and from the “Conselleria d’Educació, Investigació, Cultura i Esport, Generalitat Valenciana” (grant number AEST/2019/037)

    Impact of COVID-19 on cardiovascular testing in the United States versus the rest of the world

    Get PDF
    Objectives: This study sought to quantify and compare the decline in volumes of cardiovascular procedures between the United States and non-US institutions during the early phase of the coronavirus disease-2019 (COVID-19) pandemic. Background: The COVID-19 pandemic has disrupted the care of many non-COVID-19 illnesses. Reductions in diagnostic cardiovascular testing around the world have led to concerns over the implications of reduced testing for cardiovascular disease (CVD) morbidity and mortality. Methods: Data were submitted to the INCAPS-COVID (International Atomic Energy Agency Non-Invasive Cardiology Protocols Study of COVID-19), a multinational registry comprising 909 institutions in 108 countries (including 155 facilities in 40 U.S. states), assessing the impact of the COVID-19 pandemic on volumes of diagnostic cardiovascular procedures. Data were obtained for April 2020 and compared with volumes of baseline procedures from March 2019. We compared laboratory characteristics, practices, and procedure volumes between U.S. and non-U.S. facilities and between U.S. geographic regions and identified factors associated with volume reduction in the United States. Results: Reductions in the volumes of procedures in the United States were similar to those in non-U.S. facilities (68% vs. 63%, respectively; p = 0.237), although U.S. facilities reported greater reductions in invasive coronary angiography (69% vs. 53%, respectively; p < 0.001). Significantly more U.S. facilities reported increased use of telehealth and patient screening measures than non-U.S. facilities, such as temperature checks, symptom screenings, and COVID-19 testing. Reductions in volumes of procedures differed between U.S. regions, with larger declines observed in the Northeast (76%) and Midwest (74%) than in the South (62%) and West (44%). Prevalence of COVID-19, staff redeployments, outpatient centers, and urban centers were associated with greater reductions in volume in U.S. facilities in a multivariable analysis. Conclusions: We observed marked reductions in U.S. cardiovascular testing in the early phase of the pandemic and significant variability between U.S. regions. The association between reductions of volumes and COVID-19 prevalence in the United States highlighted the need for proactive efforts to maintain access to cardiovascular testing in areas most affected by outbreaks of COVID-19 infection

    False lumen flow patterns and their relation with morphological and biomechanical characteristics of chronic aortic dissections: Computational model compared with magnetic resonance imaging measurements

    Get PDF
    Aortic wall stiffness, tear size and location and the presence of abdominal side branches arising from the false lumen (FL) are key properties potentially involved in FL enlargement in chronic aortic dissections (ADs). We hypothesize that temporal variations on FL flow patterns, as measured in a cross-section by phase-contrast magnetic resonance imaging (PC-MRI), could be used to infer integrated information on these features. In 33 patients with chronic descending AD, instantaneous flow profiles were quantified in the FL at diaphragm level by PC-MRI. We used a lumped-parameter model to assess the changes in flow profiles induced by wall stiffness, tear size/location, and the presence of abdominal side branches arising from the FL. Four characteristic FL flow patterns were identified in 31/33 patients (94%) based on the direction of flow in systole and diastole: BA = systolic biphasic flow and primarily diastolic antegrade flow (n = 6); BR = systolic biphasic flow and primarily diastolic retrograde flow (n = 14); MA = systolic monophasic flow and primarily diastolic antegrade flow (n = 9); MR = systolic monophasic flow and primarily diastolic retrograde flow (n = 2). In the computational model, the temporal variation of flow directions within the FL was highly dependent on the position of assessment along the aorta. FL flow patterns (especially at the level of the diaphragm) showed their characteristic patterns due to variations in the cumulative size and the spatial distribution of the communicating tears, and the incidence of visceral side branches originating from the FL. Changes in wall stiffness did not change the temporal variation of the flows whereas it importantly determined intraluminal pressures. FL flow patterns implicitly codify morphological information on key determinants of aortic expansion in ADs. This data might be taken into consideration in the imaging protocol to define the predictive value of FL flows.The research leading to these results has received funding from the Subprograma de Proyectos de Investigación en Salud (FIS), Instituto de Salud Carlos III, Spain (ref. PI108/0608, PI11/01709); the Programa de ayudas destinadas a universidades, centros de investigación y fundaciones hospitalarias para la contratación de personal investigador novel (FI-DGR 2011), Spain; and the EU FP7 for research, technological development and demonstration under grant agreement VP2HF (no 611823). All authors have reported that they have no relationships relevant to the contents of this paper to disclose. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript

    False lumen rotational flow and aortic stiffness are associated with aortic growth rate in patients with chronic aortic dissection of the descending aorta : a 4D flow cardiovascular magnetic resonance study

    Get PDF
    Patency of the false lumen in chronic aortic dissection (AD) is associated with aortic dilation and long-term aortic events. However, predictors of adverse outcomes in this population are limited. The aim of this study was to evaluate the relationship between aortic growth rate and false lumen flow dynamics and biomechanics in patients with chronic, patent AD. Patients with a chronic AD with patent false lumen in the descending aorta and no genetic connective tissue disorder underwent an imaging follow-up including a contrast-enhanced 4D flow cardiovascular magnetic resonance (CMR) protocol and two consecutive computed tomography angiograms (CTA) acquired at least 1 year apart. A comprehensive analysis of anatomical features (including thrombus quantification), and false lumen flow dynamics and biomechanics (pulse wave velocity) was performed. Fifty-four consecutive patients with a chronic, patent false lumen in the descending aorta were included (35 surgically-treated type A AD with residual tear and 19 medically-treated type B AD). Median follow-up was 40 months. The in-plane rotational flow, pulse wave velocity and the percentage of thrombus in the false lumen were positively related to aortic growth rate (p = 0.006, 0.017, and 0.037, respectively), whereas wall shear stress showed a trend for a positive association (p = 0.060). These results were found irrespectively of the type of AD. In patients with chronic AD and patent false lumen of the descending aorta, rotational flow, pulse wave velocity and wall shear stress are positively related to aortic growth rate, and should be implemented in the follow-up algorithm of these patients. Further prospective studies are needed to confirm if the assessment of these parameters helps to identify patients at higher risk of adverse clinical events. The online version contains supplementary material available at 10.1186/s12968-022-00852-

    Age and computed tomography and invasive coronary angiography in stable chest pain: a prespecified secondary analysis of the discharge randomized clinical trial

    No full text
    Importance: The effectiveness and safety of computed tomography (CT) and invasive coronary angiography (ICA) in different age groups is unknown. Objective: To determine the association of age with outcomes of CT and ICA in patients with stable chest pain. Design, Setting, and Participants: The assessor-blinded Diagnostic Imaging Strategies for Patients With Stable Chest Pain and Intermediate Risk of Coronary Artery Disease (DISCHARGE) randomized clinical trial was conducted between October 2015 and April 2019 in 26 European centers. Patients referred for ICA with stable chest pain and an intermediate probability of obstructive coronary artery disease were analyzed in an intention-to-treat analysis. Data were analyzed from July 2022 to January 2023. Interventions: Patients were randomly assigned to a CT-first strategy or a direct-to-ICA strategy. Main Outcomes and Measures: MACE (ie, cardiovascular death, nonfatal myocardial infarction, or stroke) and major procedure-related complications. The primary prespecified outcome of this secondary analysis of age was major adverse cardiovascular events (MACE) at a median follow-up of 3.5 years. Results: Among 3561 patients (mean [SD] age, 60.1 [10.1] years; 2002 female [56.2%]), 2360 (66.3%) were younger than 65 years, 982 (27.6%) were between ages 65 to 75 years, and 219 (6.1%) were older than 75 years. The primary outcome was MACE at a median (IQR) follow-up of 3.5 (2.9-4.2) years for 3523 patients (99%). Modeling age as a continuous variable, age, and randomization group were not associated with MACE (hazard ratio, 1.02; 95% CI, 0.98-1.07; P for interaction = .31). Age and randomization group were associated with major procedure-related complications (odds ratio, 1.15; 95% CI, 1.05-1.27; P for interaction = .005), which were lower in younger patients. Conclusions and Relevance: Age did not modify the effect of randomization group on the primary outcome of MACE but did modify the effect on major procedure-related complications. Results suggest that CT was associated with a lower risk of major procedure-related complications in younger patients

    Reduction of cardiac imaging tests during the COVID-19 pandemic: The case of Italy. Findings from the IAEA Non-invasive Cardiology Protocol Survey on COVID-19 (INCAPS COVID)

    No full text
    Background: In early 2020, COVID-19 massively hit Italy, earlier and harder than any other European country. This caused a series of strict containment measures, aimed at blocking the spread of the pandemic. Healthcare delivery was also affected when resources were diverted towards care of COVID-19 patients, including intensive care wards. Aim of the study: The aim is assessing the impact of COVID-19 on cardiac imaging in Italy, compare to the Rest of Europe (RoE) and the World (RoW). Methods: A global survey was conducted in May–June 2020 worldwide, through a questionnaire distributed online. The survey covered three periods: March and April 2020, and March 2019. Data from 52 Italian centres, a subset of the 909 participating centres from 108 countries, were analyzed. Results: In Italy, volumes decreased by 67% in March 2020, compared to March 2019, as opposed to a significantly lower decrease (p &lt; 0.001) in RoE and RoW (41% and 40%, respectively). A further decrease from March 2020 to April 2020 summed up to 76% for the North, 77% for the Centre and 86% for the South. When compared to the RoE and RoW, this further decrease from March 2020 to April 2020 in Italy was significantly less (p = 0.005), most likely reflecting the earlier effects of the containment measures in Italy, taken earlier than anywhere else in the West. Conclusions: The COVID-19 pandemic massively hit Italy and caused a disruption of healthcare services, including cardiac imaging studies. This raises concern about the medium- and long-term consequences for the high number of patients who were denied timely diagnoses and the subsequent lifesaving therapies and procedures
    corecore