12,004 research outputs found

    Integrated system to perform surrogate based aerodynamic optimisation for high-lift airfoil

    Get PDF
    This work deals with the aerodynamics optimisation of a generic two-dimensional three element high-lift configuration. Although the high-lift system is applied only during take-off and landing in the low speed phase of the flight the cost efficiency of the airplane is strongly influenced by it [1]. The ultimate goal of an aircraft high lift system design team is to define the simplest configuration which, for prescribed constraints, will meet the take-off, climb, and landing requirements usually expressed in terms of maximum L/D and/or maximum CL. The ability of the calculation method to accurately predict changes in objective function value when gaps, overlaps and element deflections are varied is therefore critical. Despite advances in computer capacity, the enormous computational cost of running complex engineering simulations makes it impractical to rely exclusively on simulation for the purpose of design optimisation. To cut down the cost, surrogate models, also known as metamodels, are constructed from and then used in place of the actual simulation models. This work outlines the development of integrated systems to perform aerodynamics multi-objective optimisation for a three-element airfoil test case in high lift configuration, making use of surrogate models available in MACROS Generic Tools, which has been integrated in our design tool. Different metamodeling techniques have been compared based on multiple performance criteria. With MACROS is possible performing either optimisation of the model built with predefined training sample (GSO) or Iterative Surrogate-Based Optimization (SBO). In this first case the model is build independent from the optimisation and then use it as a black box in the optimisation process. In the second case is needed to provide the possibility to call CFD code from the optimisation process, and there is no need to build any model, it is being built internally during the optimisation process. Both approaches have been applied. A detailed analysis of the integrated design system, the methods as well as th

    High intensity 5 eV O-atom exposure facility for material degradation studies

    Get PDF
    An atomic oxygen exposure facility was developed for studies of material degradation. The goal of these studies is to provide design criteria and information for the manufacture of long life (20 to 30 years) construction materials for use in low Earth orbit. The studies that are being undertaken will provide: (1) absolute reaction cross sections for the engineering design problems, (2) formulations of reaction mechanisms for use in the selection of suitable existing materials and the design of new more resistant ones, and (3) the calibration of flight hardware (mass spectrometers, etc.) in order to directly relate experiments performed in low Earth orbit to ground based investigations. The facility consists of a CW laser sustained discharge source of O-atoms, an atomic beam formation and diagnostics system, a spinning rotor viscometer, and provision for using the system for calibration of actual flight instruments

    Power-Law Behavior of Power Spectra in Low Prandtl Number Rayleigh-Benard Convection

    Get PDF
    The origin of the power-law decay measured in the power spectra of low Prandtl number Rayleigh-Benard convection near the onset of chaos is addressed using long time numerical simulations of the three-dimensional Boussinesq equations in cylindrical domains. The power-law is found to arise from quasi-discontinuous changes in the slope of the time series of the heat transport associated with the nucleation of dislocation pairs and roll pinch-off events. For larger frequencies, the power spectra decay exponentially as expected for time continuous deterministic dynamics.Comment: (10 pages, 6 figures

    Biplane Fluoroscopy for Hindfoot Motion Analysis during Gait: A Model-based Evaluation

    Get PDF
    The purpose of this study was to quantify the accuracy and precision of a biplane fluoroscopy system for model-based tracking of in vivo hindfoot motion during over-ground gait. Gait was simulated by manually manipulating a cadaver foot specimen through a biplane fluoroscopy system attached to a walkway. Three 1.6-mm diameter steel beads were implanted into the specimen to provide marker-based tracking measurements for comparison to model-based tracking. A CT scan was acquired to define a gold standard of implanted bead positions and to create 3D models for model-based tracking. Static and dynamic trials manipulating the specimen through the capture volume were performed. Marker-based tracking error was calculated relative to the gold standard implanted bead positions. The bias, precision, and root-mean-squared (RMS) error of model-based tracking was calculated relative to the marker-based measurements. The overall RMS error of the model-based tracking method averaged 0.43 ± 0.22 mm and 0.66 ± 0.43° for static and 0.59 ± 0.10 mm and 0.71 ± 0.12° for dynamic trials. The model-based tracking approach represents a non-invasive technique for accurately measuring dynamic hindfoot joint motion during in vivo, weight bearing conditions. The model-based tracking method is recommended for application on the basis of the study results

    Enhanced dielectric response by disordered nanoscale/mesoscopic insulators

    Full text link
    Enhancement of the dielectric response of insulators by disorder is theoretically proposed, where the quantum interference of electronic waves through the nanoscale/mesoscopic system and its change due to external perturbations control the polarization. In the disordered case with all the states being localized, the resonant tunneling, which is topologically protected, plays a crucial role, and enhances the dielectric response by a factor 30~40 compared with the pure case. Realization of this idea with accessible materials/structures is also discussed.Comment: 4 pages including 3 figures; minor revision; a high-resolution figure available at http://appi.t.u-tokyo.ac.jp/~sonoda/papers.htm

    Sagittal Subtalar and Talocrural Joint Assessment During Ambulation With Controlled Ankle Movement (CAM) Boots

    Get PDF
    Background: The purpose of the current study was to determine sagittal plane talocrural and subtalar kinematic differences between barefoot and controlled ankle movement (CAM) boot walking. This study used fluoroscopic images to determine talar motion relative to tibia and calcaneal motion relative to talus. Methods: Fourteen male subjects (mean age 24.1 ± 3.5 years) screened for normal gait were tested. A fluoroscopy unit was used to collect images at 200 Hz during stance. Sagittal motion of the talocrural and subtalar joints were analyzed barefoot and within short and tall CAM boots. Results: Barefoot talocrural mean maximum plantar and dorsiflexion were 9.2 ± 5.4 degrees and −7.5 ± 7.4 degrees, respectively; short CAM boot mean maximum plantar and dorsiflexion were 3.2 ± 4.0 degrees and −4.8 ± 10.2 degrees, respectively; and tall CAM boot mean maximum plantar and dorsiflexion were −0.2 ± 3.5 degrees and −2.4 ± 5.1 degrees, respectively. Talocrural mean range of motion (ROM) decreased from barefoot (16.7 ± 5.1 degrees) to short CAM boot (8.0 ± 4.9 degrees) to tall CAM boot (2.2 ± 2.5 degrees). Subtalar mean maximum plantarflexion angles were 5.3 ± 5.6 degrees for barefoot walking, 4.1 ± 5.9 degrees for short CAM boot walking, and 3.0 ± 4.7 degrees for tall CAM boot walking. Mean minimum subtalar plantarflexion angles were 0.7 ± 3.2 degrees for barefoot walking, 0.7 ± 2.9 degrees for short CAM boot walking, and 0.1 ± 4.8 degrees for tall CAM boot walking. Subtalar mean ROM decreased from barefoot (4.6 ± 3.9 degrees) to short CAM boot (3.4 ± 3.8 degrees) to tall CAM boot (2.9 ± 2.6 degrees). Conclusion: Tall and short CAM boot intervention was shown to limit both talocrural and subtalar motion in the sagittal plane during ambulation. The greatest reductions were seen with the tall CAM boot, which limited talocrural motion by 86.8% and subtalar motion by 37.0% compared to barefoot. Short CAM boot intervention reduced talocrural motion by 52.1% and subtalar motion by 26.1% compared to barefoot. Clinical Relevance: Both short and tall CAM boots reduced talocrural and subtalar motion during gait. The short CAM boot was more convenient to use, whereas the tall CAM boot more effectively reduced motion. In treatments requiring greater immobilization of the talocrural and subtalar joints, the tall CAM boot should be considered

    STUDIES ON THE RECOVERY OF THE IMMUNE RESPONSE IN IRRADIATED MICE THYMECTOMIZED IN ADULT LIFE

    Get PDF
    Experiments performed on CBA mice thymectomized in adult life, exposed to lethal doses of irradiation and given tissue therapy are described. Marrow, foetal liver, or spleen cells from syngeneic donors could protect the mice against the lethal effects of irradiation. Between 30 and 70 days' postirradiation, however, marrow-treated, thymectomized irradiated mice showed evidence of trophic disturbances, such as failure to gain weight, in contrast to sham-operated, irradiated, marrow-treated controls. The immune responses of experimental and control mice were tested up to 150 days' postirradiation by challenging with sheep erythrocytes and allogeneic skin grafts. Sham-operated irradiated controls, whether protected with marrow, foetal liver, or spleen cells, produced normal immune responses when challenged at 28, 60, or 150 days after irradiation. Neither foetal liver cells nor marrow cells, in doses of up to 40 million cells per mouse, enabled thymectomized irradiated mice to recover normal immune functions. Spleen cells, from normal donors but not from neonatally thymectomized donors, restored immunological capacity in such mice. It is concluded that immunologically competent cells are present in the spleen of normal adult donors and can function in the absence of the thymus. Bone marrow, on the other hand, does not contain an adequate population of such cells but has lymphoid precursor cells, the descendants of which can become immunologically competent only in the presence of a functioning thymus mechanism

    Distribution of copper and zinc in oysters and sediments from three coastal-plain estuaries.

    Get PDF
    Copper and zinc were analyzed in oysters (Crassostrea virginica) from the Newport River estuary, North Carolina, and the Rappahannock River estuary, Virginia. Results indicated that a concentration gradient existed, higher concentrations of metals being found in animals living in fresher waters as was shown previously for oysters in the James, York, and Rappahannock estuaries in Virginia. Absorbed, precipitatcd-coprecipitated, and organic fractions of copper and zinc in the \u3c63-μm portion of the sediments from the Rappahannock and York rivers and estuaries were estimated from collections made in January 1972 and June 1973. These sediment data are discussed for both estuarine systems and are compared with metal concentrations in oysters. These comparisons indicated that the concentration gradient found in oysters does not appear to be related to the distribution of copper and zinc in the sediments. Alternative explanations for the inverse relationships between concentrations of copper and zinc in oysters and salinity arc given.https://scholarworks.wm.edu/vimsbooks/1146/thumbnail.jp

    Enhanced tracer transport by the spiral defect chaos state of a convecting fluid

    Get PDF
    To understand how spatiotemporal chaos may modify material transport, we use direct numerical simulations of the three-dimensional Boussinesq equations and of an advection-diffusion equation to study the transport of a passive tracer by the spiral defect chaos state of a convecting fluid. The simulations show that the transport is diffusive and is enhanced by the spatiotemporal chaos. The enhancement in tracer diffusivity follows two regimes. For large Peclet numbers (that is, small molecular diffusivities of the tracer), we find that the enhancement is proportional to the Peclet number. For small Peclet numbers, the enhancement is proportional to the square root of the Peclet number. We explain the presence of these two regimes in terms of how the local transport depends on the local wave numbers of the convection rolls. For large Peclet numbers, we further find that defects cause the tracer diffusivity to be enhanced locally in the direction orthogonal to the local wave vector but suppressed in the direction of the local wave vector.Comment: 11 pages, 12 figure
    • …
    corecore