685 research outputs found

    Theoretical investigation on transverse mode combustion instability for liquid propellant rockets

    Get PDF
    Mathematical solution of nonlinear transverse combustion instability problems in thin annular liquid propellant rocket chamber

    Monitoring thermal ablation via microwave tomography. An ex vivo experimental assessment

    Get PDF
    Thermal ablation treatments are gaining a lot of attention in the clinics thanks to their reduced invasiveness and their capability of treating non-surgical patients. The effectiveness of these treatments and their impact in the hospital's routine would significantly increase if paired with a monitoring technique able to control the evolution of the treated area in real-time. This is particularly relevant in microwave thermal ablation, wherein the capability of treating larger tumors in a shorter time needs proper monitoring. Current diagnostic imaging techniques do not provide effective solutions to this issue for a number of reasons, including economical sustainability and safety. Hence, the development of alternative modalities is of interest. Microwave tomography, which aims at imaging the electromagnetic properties of a target under test, has been recently proposed for this scope, given the significant temperature-dependent changes of the dielectric properties of human tissues induced by thermal ablation. In this paper, the outcomes of the first ex vivo experimental study, performed to assess the expected potentialities of microwave tomography, are presented. The paper describes the validation study dealing with the imaging of the changes occurring in thermal ablation treatments. The experimental test was carried out on two ex vivo bovine liver samples and the reported results show the capability of microwave tomography of imaging the transition between ablated and untreated tissue. Moreover, the discussion section provides some guidelines to follow in order to improve the achievable performances

    Microwave Tomography for Food Contamination Monitoring

    Get PDF
    The security of packaged food needs to be guaranteed to safeguard customers health. A raise of complaints of physical contaminations into food products pushes for the development of additional monitoring techniques to prevent any kind of hazards, but also to protect brands from customers trust loss. In this work, a prototype working at microwave frequencies is assessed and tested in a significant environment. It exploits the dielectric contrast between contaminants and food content, and it is it is mainly focused on two classes of intrusions matters, i.e. plastic and glass fragments of few mm size, that have limited detection by the existing in-line technologies, such as X-rays systems. The measurements and the resulting 3-D image reconstructions are encouraging and allow to aim at the development of an industrial prototype, monitoring packaged food in real-time along a production line

    Electromagnetic imaging and sensing for food quality and safety assessment [Guest Editorial]

    Get PDF
    The six articles in this special present to the antennas and propagation community some of the emerging research activities on the application of EM-based technologies in such a societally relevant topic. The articles address food industry applications as different as sensing food quality and food spoilage indicators and monitoring food items to detect contaminants

    A Microwave Imaging Device for Detecting Contaminants in Water-based Food Products

    Get PDF
    Food and beverage industries are paying an increasing attention to the development of new technologies for non-invasive assessment of food products. In particular, there is a need of deploying tools to detect low-density plastic, rubber, wood and glass that are unlikely to be detected by X-Rays, currently used in the most powerful commercial systems. To this end, we propose a microwave-based device, exploiting the dielectric contrast between potential intrusions (e.g., plastic fragments) and the surrounding medium, represented by the food/beverage product. In particular, this work aims to numerically assess this principle of detection to water-based products that are, due to the medium losses, a challenging category at microwaves. An antennas array surrounds the object moving along the production line, to monitor the electromagnetic signal variations with respect to a reference case. The working frequency is chosen by selecting a proper trade-off between penetration depth and image resolution. Then, a procedure, based on the application of the distorted-Born approximation is applied to reconstruct a 3-D image of the contaminant position. Finally, the successful detection of a millimetric-sized plastic sphere is presented in the case of a common commercial bottle filled with water

    A high order compact scheme for hypersonic aerothermodynamics

    Get PDF
    A novel high order compact scheme for solving the compressible Navier-Stokes equations has been developed. The scheme is an extension of a method originally proposed for solving the Euler equations, and combines several techniques for the solution of compressible flowfields, such as upwinding, limiting and flux vector splitting, with the excellent properties of high order compact schemes. Extending the method to the Navier-Stokes equations is achieved via a Kinetic Flux Vector Splitting technique, which represents an unusual and attractive way to include viscous effects. This approach offers a more accurate and less computationally expensive technique than discretizations based on more conventional operator splitting. The Euler solver has been validated against several inviscid test cases, and results for several viscous test cases are also presented. The results confirm that the method is stable, accurate and has excellent shock-capturing capabilities for both viscous and inviscid flows

    Perceived Benefits of Technology Enhanced Language Learning in Beginning Language Classes

    Get PDF
    This paper examines the perceptions of benefit of Technology EnhancedLanguage Learning (TELL) on studentsā€™ language learning, comfort &enjoyment, and increased confidence using technology at a large SouthernCalifornia University during one university term. Through a surveyadministered to 345 beginning language students, 11 tutors and 12instructors, and through selective interviews and classroom observations,several questions were examined: 1.) Perceived confidence, benefits, andcomfort/enjoyment with TELL for instructors, tutors, and students at thebeginning and end of the semester; 2.) Studentsā€™ perceived impact ofTELL between pre and post survey measures on second language skills,learning culture, student motivation to learn a language, and preparingstudents for class tests and quizzes; 3.) Whether or not target languageorthography, exposure to TELL, student gender, and instructorsā€™ ortutorsā€™ previous confidence in using TELL, impacted perception of benefitby students; 4.) Positive and negative aspects of incorporating a TELLcomponent in the language classroom for instructors and tutors. Theresults showed that incorporating TELL in a new, but limited, way in allbeginning level classes at one university was a positive experience formany participants, especially in the areas of comfort/enjoyment, andincreased confidence in using technology. However, unless tasks wereclearly tied to learning objectives, students did not recognize theirinstructional value

    Assessing a Microwave Imaging System for Brain Stroke Monitoring via High Fidelity Numerical Modelling

    Get PDF
    This work presents the outcomes of a numerical analysis based on a 3-D high fidelity model of a realistic microwave imaging system for the clinical follow-up of brain stroke. The analysis is meant as a preliminary step towards the full experimental characterization of the system, with the aim of assessing the achievable results and highlight possible critical points. The system consists of an array of twenty-four printed monopole antennas, placed conformal to the upper part of the head; each monopole is immersed into a semi-solid dielectric brick with custom permittivity, acting as coupling medium. The whole system, including the antennas and their feeding mechanism, has been numerically modeled via a custom full-wave software based on the finite element method. The numerical model generates reliable electromagnetic operators and accurate antenna scattering parameters, which provide the input data for the implemented imaging algorithm. In particular, the numerical analysis assesses the capability of the device of reliably monitoring the evolution of hemorrhages and ischemias, considering the progression from a healthy statet o an early-stage stroke
    • ā€¦
    corecore