257 research outputs found

    Search for invisible decays of sub-GeV dark photons in missing-energy events at the CERN SPS

    Full text link
    We report on a direct search for sub-GeV dark photons (A') which might be produced in the reaction e^- Z \to e^- Z A' via kinetic mixing with photons by 100 GeV electrons incident on an active target in the NA64 experiment at the CERN SPS. The A's would decay invisibly into dark matter particles resulting in events with large missing energy. No evidence for such decays was found with 2.75\cdot 10^{9} electrons on target. We set new limits on the \gamma-A' mixing strength and exclude the invisible A' with a mass < 100 MeV as an explanation of the muon g_\mu-2 anomaly.Comment: 6 pages, 3 figures; Typos corrected, references adde

    Explaining regional variations in health care utilization between Swiss cantons using panel econometric models

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>In spite of a detailed and nation-wide legislation frame, there exist large cantonal disparities in consumed quantities of health care services in Switzerland. In this study, the most important factors of influence causing these regional disparities are determined. The findings can also be productive for discussing the containment of health care consumption in other countries.</p> <p>Methods</p> <p>Based on the literature, relevant factors that cause geographic disparities of quantities and costs in western health care systems are identified. Using a selected set of these factors, individual panel econometric models are calculated to explain the variation of the utilization in each of the six largest health care service groups (general practitioners, specialist doctors, hospital inpatient, hospital outpatient, medication, and nursing homes) in Swiss mandatory health insurance (MHI). The main data source is 'Datenpool santésuisse', a database of Swiss health insurers.</p> <p>Results</p> <p>For all six health care service groups, significant factors influencing the utilization frequency over time and across cantons are found. A greater supply of service providers tends to have strong interrelations with per capita consumption of MHI services. On the demand side, older populations and higher population densities represent the clearest driving factors.</p> <p>Conclusions</p> <p>Strategies to contain consumption and costs in health care should include several elements. In the federalist Swiss system, the structure of regional health care supply seems to generate significant effects. However, the extent of driving factors on the demand side (e.g., social deprivation) or financing instruments (e.g., high deductibles) should also be considered.</p

    Initial operation of the International Gravitational Event Collaboration

    Full text link
    The International Gravitational Event Collaboration, IGEC, is a coordinated effort by research groups operating gravitational wave detectors working towards the detection of millisecond bursts of gravitational waves. Here we report on the current IGEC resonant bar observatory, its data analysis procedures, the main properties of the first exchanged data set. Even though the available data set is not complete, in the years 1997 and 1998 up to four detectors were operating simultaneously. Preliminary results are mentioned.Comment: 8 pages, 2 figures, 3 tables; Proceeding of the GWDAW'99. Submitted to the International Journal of Modern Physic

    Development of a PbWO4 Detector for Single-Shot Positron Annihilation Lifetime Spectroscopy at the GBAR Experiment

    Get PDF
    We have developed a PbWO4 (PWO) detector with a large dynamic range to measure the intensity of a positron beam and the absolute density of the ortho-positronium (o-Ps) cloud it creates. A simulation study shows that a setup based on such detectors may be used to determine the angular distribution of the emission and reflection of o-Ps to reduce part of the uncertainties of the measurement. These will allow to improve the precision in the measurement of the cross-section for the (anti)hydrogen formation by (anti)proton-positronium charge exchange and to optimize the yield of antihydrogen ion which is an essential parameter in the GBAR experiment

    The LBNO long-baseline oscillation sensitivities with two conventional neutrino beams at different baselines

    Get PDF
    The proposed Long Baseline Neutrino Observatory (LBNO) initially consists of 20\sim 20 kton liquid double phase TPC complemented by a magnetised iron calorimeter, to be installed at the Pyh\"asalmi mine, at a distance of 2300 km from CERN. The conventional neutrino beam is produced by 400 GeV protons accelerated at the SPS accelerator delivering 700 kW of power. The long baseline provides a unique opportunity to study neutrino flavour oscillations over their 1st and 2nd oscillation maxima exploring the L/EL/E behaviour, and distinguishing effects arising from δCP\delta_{CP} and matter. In this paper we show how this comprehensive physics case can be further enhanced and complemented if a neutrino beam produced at the Protvino IHEP accelerator complex, at a distance of 1160 km, and with modest power of 450 kW is aimed towards the same far detectors. We show that the coupling of two independent sub-MW conventional neutrino and antineutrino beams at different baselines from CERN and Protvino will allow to measure CP violation in the leptonic sector at a confidence level of at least 3σ3\sigma for 50\% of the true values of δCP\delta_{CP} with a 20 kton detector. With a far detector of 70 kton, the combination allows a 3σ3\sigma sensitivity for 75\% of the true values of δCP\delta_{CP} after 10 years of running. Running two independent neutrino beams, each at a power below 1 MW, is more within today's state of the art than the long-term operation of a new single high-energy multi-MW facility, which has several technical challenges and will likely require a learning curve.Comment: 21 pages, 12 figure

    Socioeconomic Status and Adherence to Preventive Measures During the COVID-19 Pandemic in Switzerland: A Population Based Digital Cohort Analysis.

    Get PDF
    OBJECTIVES To assess the association between socioeconomic status (SES) and self-reported adherence to preventive measures in Switzerland during the COVID-19 pandemic. METHODS 4,299 participants from a digital cohort were followed between September 2020 and November 2021. Baseline equivalised disposable income and education were used as SES proxies. Adherence was assessed over time. We investigated the association between SES and adherence using multivariable mixed logistic regression, stratifying by age (below/above 65 years) and two periods (before/after June 2021, to account for changes in vaccine coverage and epidemiological situation). RESULTS Adherence was high across all SES strata before June 2021. After, participants with higher equivalised disposable income were less likely to adhere to preventive measures compared to participants in the first (low) quartile [second (Adj.OR, 95% CI) (0.56, 0.37-0.85), third (0.38, 0.23-0.64), fourth (0.60, 0.36-0.98)]. We observed similar results for education. CONCLUSION No differences by SES were found during the period with high SARS-CoV-2 incidence rates and stringent measures. Following the broad availability of vaccines, lower incidence, and eased measures, differences by SES started to emerge. Our study highlights the need for contextual interpretation when assessing SES impact on adherence to preventive measures

    An ELISA method using serum derived HDAg for the sorological detection of HDV antigens and antibodies

    Full text link
    One of the main difficulties related to the detection of the Hepatitis Delta Virus (HDV) antigen and antibody has been the source of the needed HD antigen since HDV containing human and animal livers are very difficult to obtain and since yield is low. This fact prompted us to try to use the serum of patients in the acute phase of HDV infection as a source of HDAg and turn to enzyme immunoassays (EIA) instead of RIA for the sake of easiness and economy in the amount of HDAg needed. The antigen for EIA was obtained from patients during the acute phase of HDV infection and the antibody from patients who have been carriers for many years. For the detection of the antigen, a sandwich type method was employed, whereas for the antibody a competition assay was developed. In order to assess the relative specificity and sensibility of the test, the antibody assay was compared to a commercial RIA (C. RIA, Abbott) and to a non-commercial RIA (NC RIA). Forty-two sera were tested by the two methods and only in two cases discrepant results were obtained. Its is concluded that: 1) sera from patients in the acute and chronic phases of HDV infection can be used as source of both antigen and antibody, for immunoassays; 2) EIA and RIA have comparable relative specificity and sensibility and 3) EIA is easier to perform, cheaper, non-hazardous, has a longer shelf-life and saves scarce HDAg
    corecore