907 research outputs found

    Nozzle Patent

    Get PDF
    Exhaust nozzle with afterburning for generating thrus

    Onorbit IMU alignment error budget

    Get PDF
    The Star Tracker, Crew Optical Alignment Sight (COAS), and Inertial Measurement Unit (IMU) from a complex navigation system with a multitude of error sources were combined. A complete list of the system errors is presented. The errors were combined in a rational way to yield an estimate of the IMU alignment accuracy for STS-1. The expected standard deviation in the IMU alignment error for STS-1 type alignments was determined to be 72 arc seconds per axis for star tracker alignments and 188 arc seconds per axis for COAS alignments. These estimates are based on current knowledge of the star tracker, COAS, IMU, and navigation base error specifications, and were partially verified by preliminary Monte Carlo analysis

    Soluble Epoxide Hydrolase Inhibition for Ocular Diseases: Vision for the Future

    Get PDF
    Ocular diseases cause visual impairment and blindness, imposing a devastating impact on quality of life and a substantial societal economic burden. Many such diseases lack universally effective pharmacotherapies. Therefore, understanding the mediators involved in their pathophysiology is necessary for the development of therapeutic strategies. To this end, the hydrolase activity of soluble epoxide hydrolase (sEH) has been explored in the context of several eye diseases, due to its implications in vascular diseases through metabolism of bioactive epoxygenated fatty acids. In this mini-review, we discuss the mounting evidence associating sEH with ocular diseases and its therapeutic value as a target. Substantial data link sEH with the retinal and choroidal neovascularization underlying diseases such as wet age-related macular degeneration, retinopathy of prematurity, and proliferative diabetic retinopathy, although some conflicting results pose challenges for the synthesis of a common mechanism. sEH also shows therapeutic relevance in non-proliferative diabetic retinopathy and diabetic keratopathy, and sEH inhibition has been tested in a uveitis model. Various approaches have been implemented to assess sEH function in the eye, including expression analyses, genetic manipulation, pharmacological targeting of sEH, and modulation of certain lipid metabolites that are upstream and downstream of sEH. On balance, sEH inhibition shows considerable promise for treating multiple eye diseases. The possibility of local delivery of inhibitors makes the eye an appealing target for future sEH drug development initiatives

    Calibration of the Langley 16-foot transonic tunnel with test section air removal

    Get PDF
    The Langley 16-foot transonic tunnel with test section air removal (plenum suction) was calibrated to a Mach number of 1.3. The results of the calibration, including the effects of slot shape modifications, test section wall divergence, and water vapor condensation, are presented. A complete description of the wind tunnel and its auxiliary equipment is included

    The aerodynamics of a wind-tunnel fan

    Get PDF
    The vortex blade-element theory modified to apply to an axial fan working in a duct is reviewed. Thrust and power coefficients for a fan are identified with the corresponding coefficients for airplane propellers. The relation of pressure produced by the fan to the blade-element coefficients is developed. The distribution of axial velocity of fluid through a fan is assumed to be controlled by the fan itself. The radial distribution of tangential velocity imported by the fan to fluid moving through the fan is shown to be independent of the axial-velocity distribution. A nondimensional coefficient, designated the rotation constant, is introduced. This constant is based solely upon design information. The use of the rotation constant in simplifying the design of a fan for a specific operating condition is demonstrated. Based on the use of the rotation constant, a graphical method is outlined by which the performance of a given fan in a given wind tunnel may be predicted and by which the distributions of axial velocity of the fluid through the fan under various operating conditions may be established

    Orbit IMU alignment: Error analysis

    Get PDF
    A comprehensive accuracy analysis of orbit inertial measurement unit (IMU) alignments using the shuttle star trackers was completed and the results are presented. Monte Carlo techniques were used in a computer simulation of the IMU alignment hardware and software systems to: (1) determine the expected Space Transportation System 1 Flight (STS-1) manual mode IMU alignment accuracy; (2) investigate the accuracy of alignments in later shuttle flights when the automatic mode of star acquisition may be used; and (3) verify that an analytical model previously used for estimating the alignment error is a valid model. The analysis results do not differ significantly from expectations. The standard deviation in the IMU alignment error for STS-1 alignments was determined to the 68 arc seconds per axis. This corresponds to a 99.7% probability that the magnitude of the total alignment error is less than 258 arc seconds

    Retinoblastoma, the visible CNS tumor: A review

    Get PDF
    The pediatric ocular cancer retinoblastoma is the only central nervous system (CNS) tumor readily observed without specialized equipment: it can be seen by, and in, the naked eye. This accessibility enables unique imaging modalities. Here, we review this cancer for a neuroscience audience, highlighting these clinical and research imaging options, including fundus imaging, optical coherence tomography, ultrasound, and magnetic resonance imaging. We also discuss the subtype of retinoblastoma driven by the MYCN oncogene more commonly associated with neuroblastoma, and consider trilateral retinoblastoma, in which an intracranial tumor arises along with ocular tumors in patients with germline RB1 gene mutations. Retinoblastoma research and clinical care can offer insights applicable to CNS malignancies, and also benefit from approaches developed elsewhere in the CNS

    The Belt Method for Measuring Pressure Distribution

    Get PDF
    The measurement of pressure distribution may be accomplished rapidly for any number of locations deemed necessary in model or full-scale investigations by use of the "belt" method. Reasonable accuracy may be obtained by careful use of this method
    • …
    corecore