75 research outputs found

    In vitro comparison of the effects of rough and polished stem surface finish on pressure generation in cemented hip arthroplasty

    Get PDF
    Background and purpose High pressures around implants can cause bone lysis and loosening. We investigated how pressures are generated around cemented femoral stems

    In vitro influence of stem surface finish and mantle conformity on pressure generation in cemented hip arthroplasty

    Get PDF
    Background and purpose Under physiological loads, debonded cemented femoral stems have been shown to move within their cement mantle and generate a fluid pump that may facilitate peri-prosthetic osteolysis by pressurizing fluid and circulating wear debris. The long-term physiological loading of rough and polished tapered stems in vitro has shown differences in performance, with greater interface pressures generated by the rough stems. In this study we investigated the individual effects of stem surface finish, degree of mantle wear, and mode of loading on the stem pump mechanism

    Surgical treatment of scoliosis: a review of techniques currently applied

    Get PDF
    In this review, basic knowledge and recent innovation of surgical treatment for scoliosis will be described. Surgical treatment for scoliosis is indicated, in general, for the curve exceeding 45 or 50 degrees by the Cobb's method on the ground that

    Evaluation of the function and quality of life of patients submitted to girdlestone's resection arthroplasty

    Get PDF
    OBJECTIVES: To evaluate function and quality of life of patients submitted to Girdlestone's arthroplasty, and to compare outcomes between unilateral Girdlestone's group with the group with contralateral total hip prosthesis. METHODS: Cross-sectional study where 9 patients were evaluated with unilateral Girdlestone's and 3 with Girdlestone's in one hip and contralateral total hip prosthesis. The evaluation consisted in filling in a generic questionnaire on quality of life SF-36 and a specific questionnaire for hip function Harris Hip Score (HHS). The comparison between groups was made by using the Student's t-test and the Fisher's test. RESULTS: The patients of the unilateral Girdlestone's group presented a higher number of SF-36 domains classified as high, although 77.8% of these showed poor results on the HHS. All patients had a leg-length discrepancy and positive Trendelenburg's test, which led to limping gait in 11 of 12 patients evaluated. Of these, only 6 underwent physiotherapy after surgery. CONCLUSION: Girdlestone's postoperative quality of life and function in a Brazilian population still requires further studies, because these outcomes are indicative of study variables' behavior and cannot be regarded as definite.OBJETIVOS: Avaliar a função e a qualidade de vida dos pacientes pós-artroplastia de Girdlestone e comparar os resultados entre os grupos Girdlestone unilateral e o grupo com prótese total de quadril contralateral. MÉTODOS: estudo transversal no qual foram avaliados 9 pacientes com Girdlestone unilateral e 3 com Girdlestone em um quadril e prótese total no quadril contralateral. A avaliação constitui-se em aplicar o questionário genérico de qualidade de vida SF-36 e um questionário funcional específico para o quadril, Harris Hip Score (HHS). A comparação dos grupos foi realizada usando-se o teste t- Student e o teste de Fisher. RESULTADOS: Os pacientes do grupo Girdlestone unilateral apresentaram maior quantidade de domínios do SF-36 classificados como elevados, embora 77,8% destes tenham obtido resultados ruins no HHS. Todos os pacientes apresentaram o teste de Trendelenburg positivo e discrepância de membros, o que levou à marcha claudicante em 11 dos 12 pacientes avaliados. Destes, apenas 6 submeteram-se a fisioterapia pós-operatória. CONCLUSÃO: A qualidade de vida e a função pós-operatória de Girdlestone, na população brasileira, ainda necessita ser mais pesquisada, pois estes resultados são indicações do comportamento das variáveis de estudo e não podem ser consideradas encerradas.Universidade Federal de São Paulo (UNIFESP) Escola Paulista de Medicina Departamento de Ortopedia e TraumatologiaUNIFESP-EPM DOTUNIFESP, EPM, Depto. de Ortopedia e TraumatologiaUNIFESP, EPM DOTSciEL

    Adult scoliosis can be reduced through specific SEAS exercises: a case report

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>It has been known since many years that scoliosis can continue to progress after skeletal maturity: the rate of progression has shown to be linear, and it can be used to establish an individual prognosis. Once there is progression there is an indication for treatment: usually it is proposed a surgical one. There are very few papers on an alternative rehabilitation approach; since many years we propose specific SEAS exercises and the aim of this study is to present one case report on this approach.</p> <p>Case presentation</p> <p>All radiographs have been measured blindly twice using the same protractor by one expert physician whose repeatability error proved to be < 3° Cobb; the average measurement has been used. In this case a 25 years old female scoliosis patient, previously treated from 14 (Risser 1) to 19 years of age with a decrease of the curve from 46° to 37°, showed a progression of 10° Cobb in 6 years. The patient has then been treated with SEAS exercises only, and in one year progression has been reverted from 47° to 28.5°.</p> <p>Conclusion</p> <p>A scoliosis curve is made of different components: the structural bony and ligamentous components, and a postural one that counts up to 9° in children, while it has not been quantified in adults. This case shows that when adult scoliosis aggravates it is possible to intervene with specific exercises (SEAS) not just to get stability, but to recover last years collapse. The reduction of scoliotic curve through rehabilitation presumably does not indicate a reduction of the bone deformity, but rely on a recovery of the upright postural collapse. This reduction can decrease the chronic asymmetric load on the spine and, in the long run, reduce the risks of progression.</p

    Stem subsidence of polished and rough double-taper stems: In vitro mechanical effects on the cement-bone interface

    Get PDF
    Background and purpose Many clinical reports have indicated that polished hip stems show better clinical results than rough stems of the same geometry. It is still unknown, however, what the mechanical effects are of different surface finishes on the cement at the cement-bone interface. We compared mechanical effects in an in vitro cemented hip arthroplasty model

    Congenital hip dysplasia treated by total hip arthroplasty using cementless tapered stem in patients younger than 50 years old: results after 12-years follow-up

    Get PDF
    Background Congenital hip dysplasia may lead to severe acetabular and femoral abnormalities that can make total hip arthroplasty a challenging procedure. We assessed a series of patients affected by developmental hip dysplasia treated with total hip arthroplasty using cementless tapered stem and here we report the outcomes at long-term follow-up. Materials and methods Twenty-eight patients (24 women and 4 men) aged between 44 and 50 years (mean 47 years) were observed. Clinical evaluation was rated with the Harris Hip Score. Radiographic evaluation consisted in standard anteroposterior and axial view radiographs of the hip. According to Crowe’s classification, 16 hips presented dysplasia grade 1, 14 grade 2, and 4 grade 3. All patients were treated with total hip arthroplasty using a cementless tapered stem (Wagner Cone Prosthesis). Six patients were operated bilaterally, with a totally of 34 hips operated. After surgery, the patients were clinically and radiographically checked at 3, 6, and 12 months and yearly thereafter until an average follow-up of 12 years (range 10–14 years). Results Average Harris Hip Score was 56 ± 9 (range 45–69) preoperatively, 90 ± 9 (range 81–100) 12 months after surgery, and 91 ± 8 (range 83–100) at last follow-up. Radiographic evaluation demonstrated excellent osteointegration of the implants. Signs of bone resorption were present in 6 hips, nevertheless no evidence of loosening was observed and none of the implants has been revised. Conclusions Even in dysplasic femur, the tapered stem allowed adequate stability and orientation of the implant. We consider tapered stem a suitable option for total hip arthroplasty in developmental hip dysplasia, also in case of young patients, thanks to the favourable long-term results

    Spinal deformities rehabilitation - state of the art review

    Get PDF
    corecore