    Results of a FRSI material test under Space Shuttle ascent conditions in the Ames Research Center 9x7 foot supersonic wind tunnel (OS13). Space Shuttle aerothermodynamic data report

    Get PDF
    A test was conducted in the NASA/ARC 9 x 7 foot supersonic wind tunnel to verify the integrity of Felt Reusable Surface Insulation (FRSI) material in a panel flutter environment. A FRSI sample panel was subjected to the shocks, pressure gradients, and turbulence characteristics encountered at dynamic pressure 1.5 times the 3(sigma) dispersed trajectory flight conditions of the Space Shuttle. Static and fluctuating pressure data were obtained for Mach numbers ranging from 1.55 to 2.5 with dynamic pressures of 625 to 1250 psf. The FRSI panel suffered no appreciable damage as a result of the test

    Results of the space shuttle vehicle ascent air data system probe calibration test using a 0.07-scale external tank forebody model (68T) in the AEDC 16-foot transonic wind tunnel (IA-310), volume 1

    Get PDF
    A recalibration of the Space Shuttle Vehicle Ascent Air Data System probe was conducted in the Arnold Engineering Development Center (AEDC) transonic wind tunnel. The purpose was to improve on the accuracy of the previous calibration in order to reduce the existing uncertainties in the system. A probe tip attached to a 0.07-scale External Tank Forebody model was tested at angles of attack of -8 to +4 degrees and sideslip angles of -4 to +4 degrees. High precision instrumentation was used to acquire pressure data at discrete Mach numbers ranging from 0.6 to 1.55. Pressure coefficient uncertainties were estimated at less than 0.0020. Data is given in graphical and tabular form

    Extensions of Tutte\u27s wheels-and-whirls theorem

    Get PDF
    Tutte\u27s wheels-and-whirls theorem states that if M is a 3-connected matroid and, for every element e, both the deletion and the contraction of e destroy 3-connectivity, then M is a wheel or a whirl. We prove some extensions of this theorem, one of which states that if M is 3-connected and has both a wheel and a whirl minor, then either M has only seven elements or there is some element the deletion or contraction of which maintains 3-connectivity and leaves a matroid with both a wheel and a whirl minor. © 1992

    Efficacy, safety, and patient acceptability of the Essureâ„¢ procedure

    Get PDF
    The Essureâ„¢ system for permanent contraception was developed as a less invasive method of female sterilization. Placement of the Essureâ„¢ coil involves a hysteroscopic transcervical technique. This procedure can be done in a variety of settings and with a range of anesthetic options. More than eight years have passed since the US Food and Drug Administration approval of Essureâ„¢. Much research has been done to evaluate placement success, adverse outcomes, satisfaction, pain, and the contraceptive efficacy of the Essureâ„¢. The purpose of this review is to summarize the available literature regarding the efficacy, safety, and patient satisfaction with this new sterilization technique

    SOST Inhibits Prostate Cancer Invasion.

    Get PDF
    Inhibitors of Wnt signaling have been shown to be involved in prostate cancer (PC) metastasis; however the role of Sclerostin (Sost) has not yet been explored. Here we show that elevated Wnt signaling derived from Sost deficient osteoblasts promotes PC invasion, while rhSOST has an inhibitory effect. In contrast, rhDKK1 promotes PC elongation and filopodia formation, morphological changes characteristic of an invasive phenotype. Furthermore, rhDKK1 was found to activate canonical Wnt signaling in PC3 cells, suggesting that SOST and DKK1 have opposing roles on Wnt signaling in this context. Gene expression analysis of PC3 cells co-cultured with OBs exhibiting varying amounts of Wnt signaling identified CRIM1 as one of the transcripts upregulated under highly invasive conditions. We found CRIM1 overexpression to also promote cell-invasion. These findings suggest that bone-derived Wnt signaling may enhance PC tropism by promoting CRIM1 expression and facilitating cancer cell invasion and adhesion to bone. We concluded that SOST and DKK1 have opposing effects on PC3 cell invasion and that bone-derived Wnt signaling positively contributes to the invasive phenotypes of PC3 cells by activating CRIM1 expression and facilitating PC-OB physical interaction. As such, we investigated the effects of high concentrations of SOST in vivo. We found that PC3-cells overexpressing SOST injected via the tail vein in NSG mice did not readily metastasize, and those injected intrafemorally had significantly reduced osteolysis, suggesting that targeting the molecular bone environment may influence bone metastatic prognosis in clinical settings

    Molecular Subtyping of Bacillus anthracis and the 2001 Bioterrorism-Associated Anthrax Outbreak, United States

    Get PDF
    Molecular subtyping of Bacillus anthracis played an important role in differentiating and identifying anthrax strains during the 2001 bioterrorism-associated outbreak. Because B. anthracis has a low level of genetic variability, only a few subtyping methods, with varying reliability, exist. We initially used multiple-locus variable-number tandem repeat analysis (MLVA) to subtype 135 B. anthracis isolates associated with the outbreak. All isolates were determined to be of genotype 62, the same as the Ames strain used in laboratories. We sequenced the protective antigen gene (pagA) from 42 representative outbreak isolates and determined they all had a pagA sequence indistinguishable from the Ames strain (PA genotype I). MLVA and pagA sequencing were also used on DNA from clinical specimens, making subtyping B. anthracis possible without an isolate. Use of high-resolution molecular subtyping determined that all outbreak isolates were indistinguishable by the methods used and probably originated from a single source. In addition, subtyping rapidly identified laboratory contaminants and non-outbreak–related isolates

    Results of the space shuttle vehicle ascent air data system probe calibration test using a 0.07-scale external tank forebody model (68T) in the AEDC 16-foot transonic wind tunnel (IA-310), volume 2

    Get PDF
    A recalibration of the Space Shuttle Vehicle Ascent Air Data System probe was conducted in the Arnold Engineering and Development Center (AEDC) transonic wind tunnel. The purpose was to improve on the accuracy of the previous calibration in order to reduce the existing uncertainties in the system. A probe tip attached to a 0.07-scale External Tank Forebody model was tested at angles of attack of -8 to +4 degrees and sideslip angles of -4 to +4 degrees. High precision instrumentation was used to acquire pressure data at discrete Mach numbers ranging from 0.6 to 1.55. Pressure coefficient uncertainties were estimated at less than 0.0020. Additional information is given in tabular form

    Breath Stable Isotope Analysis Serves as a Non-invasive Analytical Tool to Demonstrate Dietary Changes in Adolescent Students Over Time

    Get PDF
    Concern about adolescent diets, obesity, and the associated health risks have been growing in the United States. This inspired former First Lady Michelle Obama to spearhead the Healthy Hunger-Free Kids Act (HHFKA), which made changes to the national school lunch program by increasing servings of whole grains, fruits, and vegetables. Our study examined the variability of student carbohydrate sources throughout the day and before and after the implementation of HHFKA using a stable isotope dietary biomarker. This method uses carbon stable isotope values of exhaled CO2 breath (δ13Cbreath) and provides a quantitative, non-invasive measure. δ13Cbreath samples were collected throughout the day from students (n = 31) that attended a public high school in Salt Lake City, UT. δ13Cbreath measurements reflected the short-term carbohydrate inputs from the previous meal. Carbohydrate sources were not consistent throughout the day; most students had their lowest inputs of corn/sugar-based carbohydrates after lunch. We compared our results with an earlier study that had been conducted pre-HHFKA. After-lunch δ13Cbreath values decreased significantly between the two time points, suggesting an increase in whole grain, fruit, and vegetable carbohydrates in the lunch program. Our results demonstrated that δ13Cbreath measurements provide a valuable tool to examine carbohydrate sources in an individual's diet throughout the day. We believe that this tool could be beneficial to studies examining the relationship between sugar sweetened beverages, added sugars, and refined carbohydrates and health outcomes like diabetes and obesity in both adolescent and adult populations.Fil: Mancuso, Christy J.. University of New Mexico. Department of Biology; Estados UnidosFil: Cornwall, Collette M.. Highland High School; Estados UnidosFil: Robinson, Swede. Highland High School; Estados UnidosFil: Valenzuela, Luciano Oscar. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Sociales. Departamento de Arqueología. Laboratorio de Ecología Evolutiva Humana (Sede Quequén); Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil; ArgentinaFil: Ehleringer, James R.. University Of Utah. Department Of Biology; Estados Unido

    Phase Change Material Device for Spacecraft Thermal Control

    Full text link
    On board a satellite, the experiments and subsystems have to be maintained within specified temperature limits. Phase Change Materials (PCM) offer the possibility to store thermal energy directly as latent heat of fusion. Usually, the melting PCM can easily be used in reversible, closed systems. Two advantages of a PCM device are the stability of temperature control and the absence of moving parts. The heat-storage requirement is mainly defined by the duty cycle along the orbital period. A trade-off is presented for typical missions, which takes into account the temperature range, the weight and thermal conductivity of the PCM device together with the specific design of the container. Candidates PCM for space applications are reviewed according to their main characteristics such as latent heat, phase transition temperature, conductivity, density but also corrosion potential, hysteresis and ageing. Potential weight and power gains are finally presented for selected missions
    • …