39 research outputs found

    Search of dark-matter axions in the microwave frequency range with full-wave modal techniques

    Get PDF
    Axions, originally proposed to solve the strong Charge-Parity problem of Quantum Chromo-Dynamics theory, emerge now as leading candidates of dark matter. In fact, the search of dark-matter axions in the microwave frequency range has been developed by different research groups during the last twenty years. In this demanding scenario, several microwave passive components (haloscopes) have been designed and fabricated for such axions detection based on the use of cavities and multi-cavities. From an electromagnetic point of view, comercial software (ANSFT HFSS, CST MICROWAVE STUDIO, etc ) has been employed for the design of different kind of haloscopes. In this work we propose to use the BI-RME 3D method (Boundary Integral – Resonant Mode Expansion) as an alternative to analyze the axion-photon coupling existing within an haloscope. This full-wave modal technique has provided interesting wide-band results for the design of new haloscopes

    First results of the CAST-RADES haloscope search for axions at 34.67 µeV

    Get PDF
    We present results of the Relic Axion Dark-Matter Exploratory Setup (RADES), a detector which is part of the CERN Axion Solar Telescope (CAST), searching for axion dark matter in the 34.67 µeV mass range. A radio frequency cavity consisting of 5 sub-cavities coupled by inductive irises took physics data inside the CAST dipole magnet for the first time using this filter-like haloscope geometry. An exclusion limit with a 95% credibility level on the axion-photon coupling constant of ga¿ ¿ 4 × 10-13 GeV-1 over a mass range of 34.6738 µeV < ma< 34.6771 µeV is set. This constitutes a significant improvement over the current strongest limit set by CAST at this mass and is at the same time one of the most sensitive direct searches for an axion dark matter candidate above the mass of 25 µeV. The results also demonstrate the feasibility of exploring a wider mass range around the value probed by CAST-RADES in this work using similar coherent resonant cavities. © 2021, The Author(s)

    Physics potential of the International Axion Observatory (IAXO)

    Get PDF
    We review the physics potential of a next generation search for solar axions:the International Axion Observatory (IAXO). Endowed with a sensitivity todiscover axion-like particles (ALPs) with a coupling to photons as small asgaγ1012g_{a\gamma}\sim 10^{-12} GeV1^{-1}, or to electrons gaeg_{ae}\sim1013^{-13},IAXO has the potential to find the QCD axion in the 1 meV\sim1 eV mass rangewhere it solves the strong CP problem, can account for the cold dark matter ofthe Universe and be responsible for the anomalous cooling observed in a numberof stellar systems. At the same time, IAXO will have enough sensitivity todetect lower mass axions invoked to explain: 1) the origin of the anomalous"transparency" of the Universe to gamma-rays, 2) the observed soft X-ray excessfrom galaxy clusters or 3) some inflationary models. In addition, we reviewstring theory axions with parameters accessible by IAXO and discuss theirpotential role in cosmology as Dark Matter and Dark Radiation as well as theirconnections to the above mentioned conundrums

    Thin Film (High Temperature) Superconducting Radiofrequency Cavities for the Search of Axion Dark Matter

    Get PDF
    5 pages, 6 figures. v2: minor updates after referee comments, matches published version in IEEEThe axion is a hypothetical particle which is a candidate for cold dark matter. Haloscope experiments directly search for these particles in strong magnetic fields with RF cavities as detectors. The Relic Axion Detector Exploratory Setup (RADES) at CERN in particular is searching for axion dark matter in a mass range above 30 μ\mueV. The figure of merit of our detector depends linearly on the quality factor of the cavity and therefore we are researching the possibility of coating our cavities with different superconducting materials to increase the quality factor. Since the experiment operates in strong magnetic fields of 11 T and more, superconductors with high critical magnetic fields are necessary. Suitable materials for this application are for example REBa2_2Cu3_3O7x_{7-x}, Nb3_3Sn or NbN. We designed a microwave cavity which resonates at around 9~GHz, with a geometry optimized to facilitate superconducting coating and designed to fit in the bore of available high-field accelerator magnets at CERN. Several prototypes of this cavity were coated with different superconducting materials, employing different coating techniques. These prototypes were characterized in strong magnetic fields at 4.2 K.This project has received funding from the European Union’s Horizon 2020 Research and Innovation programme under Grant Agreement No 730871 (ARIES-TNA). BD and JG acknowledge funding through the European Research Council under grant ERC-2018-StG-802836 (AxScale). We also acknowledge funding via the Spanish Agencia Estatal de Investigacion (AEI) and Fondo Europeo de Desarrollo Regional (FEDER) under project PID2019- 108122GB-C33, and the grant FPI BES-2017-079787 (under project FPA2016-76978-C3-2-P). Furthermore we acknowledge support from SuMaTe RTI2018-095853-B-C21 from MICINN co-financed by the European Regional Development Fund, Center of Excellence award Severo Ochoa CEX2019- 000917-S and CERN under Grant FCCGOV-CC-0208 (KE4947/ATS).With funding from the Spanish government through the ‘Severo Ochoa Centre of Excellence’ accreditation (CEX2019-000917-S).Peer reviewe

    Versatilidad del colgajo en hacha para reconstrucción de lesiones en punta de dedo Versatility of the hatchet flap for reconstruction of fingertip injuries

    No full text
    El colgajo en hacha descrito por Emmet, ha sido recientemente aplicado por Tuncali et al. en amputaciones de punta de dedo. Este sencillo colgajo triangular puede ser utilizado tanto en amputaciones transversas como oblicuas. El objetivo del estudio es presentar nuestra experiencia con este versátil colgajo en la reconstrucción de punta de dedo. Incluimos en el estudio 5 pacientes que completaron un periodo de seguimiento de un año. El nivel de amputación fue considerado de acuerdo con la clasificación de Ishikawa. Los pacientes fueron preguntados por la existencia de intolerancia al frío, hipersensibilidad y dolor. Empleamos diferentes diseños del colgajo en hacha que se aplicaron en pacientes pediátricos y adultos con amputaciones múltiples, lesiones del primer dedo del pie o de la mano, de dedos largos y en reconstrucciones con doble colgajo. La media de tamaño del defecto fue 2,2 x 1,4 cm. En todos los pacientes el colgajo aportó almohadillado protector y resultados estéticos. Se observó rigidez articular en un paciente debido a la combinación con un colgajo de dedo cruzado. El objetivo de toda reconstrucción de punta de dedo es proveer cobertura pulpar suficiente al hueso para evitar inestabilidad y pérdida de sensibilidad como consecuencia de la reconstrucción. El colgajo en hacha es una opción versátil y segura para la reconstrucción de punta de dedo. Los diferentes diseños pueden ser usados conforme a nuestras necesidades.<br>The hatchet flap described by Emmet, has been recently applied by Tuncali et al. in fingertip amputations. This single triangular flap can be used in different types of injuries, as transverse and lateral oblique amputations. The aim of our study was to present the authors&acute; experience with this versatile flap in fingertip reconstruction. Five patients who have completed their 1-year follow-up period were included in the study. The level of amputation was categorized according Ishikawa classification. The patients were queried about the existence of cold intolerance, hypersensitivity and pain. Different designs of the hatchet flap were used. The authors applied this flap in adult an pediatric patients, with single or multiple amputations, toe, thumb and long finger lessions, or reconstructions with double flap. The average defect size was 2,2 x 1,4 cm. In all the patients the flap has provided protective padding and aesthetic results. Joint stiffness was observed in one patient because the combination with a cross-finger flap. The concern with all reconstructions of the fingertip is to provide adequate pulp cover of the bone, to avoid bone tip tenderness and to avoid loss of sensibility as a result of the reconstruction. The hatchet flap is a versatile and safe alternative for fingertip reconstruction. Different designs can be used in accordance with our necessities

    Comunicación científica (XIX). De la eHealth a la mHealth. Apps en pediatría

    Full text link
    [ES] La generalización del uso de dispositivos móviles ha propiciado el desarrollo de un enorme y variado catálogo de aplicaciones en continua regeneración que se ha extendido al ámbito de la salud y que auxilian en la práctica médica a los profesionales médicos, al tiempo que permiten el desarrollo de un papel proactivo por parte del paciente en las tareas de seguimiento. En este trabajo se describen el contexto y las características de estas aplicaciones en el campo de la salud, y se proporciona un listado con algunas de las más destacadas en el campo de la pediatría, útiles para la actualización de conocimientos, el auxilio en las labores de gestión y la consulta sobre diagnósticos, así como las más empleadas por los padres para facilitar el seguimiento y la monitorización. Asimismo, se ofrece un listado con los principales directorios y buscadores de aplicaciones para facilitar la búsqueda entre una oferta tan variada y cada día más amplia, además de las iniciativas nacionales e internacionales orientadas.[EN] The widespread use of mobile devices has led to the development of a wideand varied application catalog, which has spread to the health sector. These applications aidmedical professionals in the medical practice, while helping in developing a proactive role by the patients in the monitoring tasks. The context and featuresof theapplications used in the health sector aredescribed and a list of some of the most outstanding applications in the field of pediatrics is provided, including updating practitioners¿ knowledge, help in management tasks, consultation ondiagnostics and those most used by parents to facilitate tracking and monitoring. A list of the main directories and search engines for apps is also presented to help findingproper applications among the wide range of available applications. Besides, national and international initiatives to assess the quality and reliability of these applications are also presented.Navarro Molina, C.; López-Gil, J.; Castelló-Cogollos, L.; González De Dios, J.; Aleixandre Benavent, R. (2015). Comunicación científica (XIX). De la eHealth a la mHealth. Apps en pediatría. Acta pediátrica española. 73(11):313-318. http://hdl.handle.net/10251/91943S313318731

    Versatilidad del colgajo en hacha para reconstrucción de lesiones en punta de dedo

    No full text
    El colgajo en hacha descrito por Emmet, ha sido recientemente aplicado por Tuncali et al. en amputaciones de punta de dedo. Este sencillo colgajo triangular puede ser utilizado tanto en amputaciones transversas como oblicuas. El objetivo del estudio es presentar nuestra experiencia con este versátil colgajo en la reconstrucción de punta de dedo. Incluimos en el estudio 5 pacientes que completaron un periodo de seguimiento de un año. El nivel de amputación fue considerado de acuerdo con la clasificación de Ishikawa. Los pacientes fueron preguntados por la existencia de intolerancia al frío, hipersensibilidad y dolor. Empleamos diferentes diseños del colgajo en hacha que se aplicaron en pacientes pediátricos y adultos con amputaciones múltiples, lesiones del primer dedo del pie o de la mano, de dedos largos y en reconstrucciones con doble colgajo. La media de tamaño del defecto fue 2,2 x 1,4 cm. En todos los pacientes el colgajo aportó almohadillado protector y resultados estéticos. Se observó rigidez articular en un paciente debido a la combinación con un colgajo de dedo cruzado. El objetivo de toda reconstrucción de punta de dedo es proveer cobertura pulpar suficiente al hueso para evitar inestabilidad y pérdida de sensibilidad como consecuencia de la reconstrucción. El colgajo en hacha es una opción versátil y segura para la reconstrucción de punta de dedo. Los diferentes diseños pueden ser usados conforme a nuestras necesidades

    Bibliometrics and indicators of scientific activity (1). The evaluation of research and scientific activity in pediatrics through bibliometrics

    Full text link
    [EN] Bibliometrics is the use of statistical methods in the analysis of a body of literature to reveal the historical development of subject fields and patterns of authorship, publication, and use. The interest aroused by bibliometric studies in the scientific community has been increasing, especially in the biomedical field. The objective of this work has been to address the methodological considerations to be taken into account when preparing a bibliometric study, especially those related to the knowledge of the area to be studied and the national and international bibliographic databases of data origin. The main applications of the bibliometric indicators and several examples related to Acta Pediátrica Española are described, such as the evolution of the number of articles included in Scopus, the ranking of institutions of origin, the network of cowords and some of the indicators offered by Scimago Journal & Country Rank.[ES] La bibliometría es la utilización de métodos estadísticos en el análisis de la bibliografía para mostrar el desarrollo histórico de los campos científicos y los patrones de autoría, publicación y uso. El interés que han despertado los estudios bibliométricos en la comunidad científica ha sido creciente, especialmente en el campo biomédico. El objetivo de este trabajo era abordar las consideraciones metodológicas a tener en cuenta a la hora de elaborar un estudio bibliométrico, sobre todo las referidas al conocimiento del área de estudio y las bases de datos bibliográficas nacionales e internacionales de procedencia de los datos. Se enumeran las principales aplicaciones de los indicadores bibliométricos y se presentan algunos ejemplos de ellos referidos a Acta Pediátrica Española, como la evolución del número de artículos incluidos en Scopus, el ranking de las instituciones de procedencia, la red de cowords de los trabajos de Acta Pediátrica Española y algunos de los indicadores que ofrece Scimago Journal & Country Rank.Aleixandre-Benavent, R.; González De Dios, J.; Castelló-Cogollos, L.; Navarro Molina, C.; Alonso-Arroyo, A.; Vidal-Infer, A.; Lucas-Domínguez, R. (2017). Bibliometría e indicadores de actividad científica (1). La evaluación de la investigación y de la actividad científica en pediatría a través de la bibliometría. Acta pediátrica española. 75(1-2):18-25. http://hdl.handle.net/10251/103517S1825751-
    corecore