1,917 research outputs found

    Coherent microwave backscatter of natural snowpacks

    Get PDF
    The backscatter of natural snowpacks was measured using a swept-frequency system operating from 5.8 to 8.0 GHz. Snow layering produced sequences of maxima and minima in backscatter intensity, with typical peak-to-valley ratios of 15 db. Wetness produced in the upper portion of the snowpack by solar heat input enhanced the effect of layering. The layer response persisted for incidence exhibits predominantly coherent properties. Frequency modulation of the incident signal masked the layer response by averaging the unmodulated response over the bandwidth represented by the modulation. Further changes in backscatter were attributed to changes in wetness in the surface regions of the snowpack; for a fixed frequency of 13.5 GHz and incidence angle of 39 deg, the backscatter decreased typically 15 db between 11 A.M. and noon, and returned to approximately its initial level of overnight

    Snow wetness measurements for melt forecasting

    Get PDF
    A microwave technique for directly measuring snow pack wetness in remote installations is described. The technique, which uses satellite telemetry for data gathering, is based on the attenuation of a microwave beam in transmission through snow

    A broadband THz receiver for low background space applications

    Get PDF
    We have developed a sensitive bolometric receiver for low background space applications. In a 10 percent bandwidth at 1 THz, this receiver is approximately 100 times more sensitive than a quantum limited heterodyne receiver with a 1 GHz IF bandwidth. This receiver is designed to be used for the long wavelength band (200-700 microns) in the MIPS instrument on NASA's SIRTF satellite. The bolometers are cooled to 100 mK by an adiabatic demagnetization refrigerator. Roughly 60 g of cesium chrome alum salt is partially demagnetized to 100 mK, followed by a slow regulated downramp to compensate for the heat leak. The hold time of the ADR system is about 18 hours with a temperature stability of delta T(sub rms) approx. equals 10 micro-K. The composite bolometers have electrical responsivities of 10(exp 9)V/W and electrical NEP's of about 3x10(exp -17) W/square root of Hz. The bolometer signals are read out by JFET preamplifiers located on the helium plate and operated at 120 K. We have addressed a number of space qualification issues, such as the development of an analog magnet controller, construction of a cryogenic shake-table for bolometers and selection of the paramagnetic salt CCA which can survive a bakeout at 50 C. The receiver is scheduled to be flown in the spring of 1992 on a balloon telescope. This flight has a dual purpose. One is to provide realistic test of the capabilities of the new receiver. The other is to search for anisotropies in the cosmic microwave background on scales of a few degrees

    The JAWSAT Mission: Final Report and Lessons Learned

    Get PDF
    One Stop Satellite Solutions and the Center for Aerospace Technology recently completed the JAWSAT mission. This was the first flight of the Minotaur launch vehicle and the first time eleven separate micro and pico satellites were placed into orbit with one launch. The JAWSAT project required both new technical designs as well as new programmatic ways of conducting a space mission. Main stream, large satellite, methods were not adequate. Technical lessons learned on this project range from new techniques in versatile, low-cost, structural design to a reasonable method of qualifying commercial off-theshelf electronic components. New methods of final integration and ride sharing were also invented. In program management, new methods in documentation, technical exchange, design review and reporting were developed. Lessons related to schedule, goals, budget, team building, logistics of personnel and materials, and risk assessment and management were studied and implemented. The positive and negative lessons learned in this large small-satellite mission will be of interest to the small satellite community and give insight to those who plan future missions

    Guanfacine treatment improves ADHD phenotypes of impulsivity and hyperactivity in a neurofibromatosis type 1 mouse model

    Get PDF
    BACKGROUND: Neurofibromatosis type 1 (NF1) is an autosomal dominant disorder with a mutation in one copy of the neurofibromin gene (NF1+/-). Even though approximately 40-60% of children with NF1 meet the criteria for attention deficit hyperactivity disorder (ADHD), very few preclinical studies, if any, have investigated alterations in impulsivity and risk-taking behavior. Mice with deletion of a single NF1 gene (Nf1+/-) recapitulate many of the phenotypes of NF1 patients. METHODS: We compared wild-type (WT) and Nf1+/- mouse strains to investigate differences in impulsivity and hyperactivity using the delay discounting task (DDT), cliff avoidance reaction (CAR) test, and open field. We also investigated whether treatment with the clinically effective alpha-2A adrenergic receptor agonist, guanfacine (0.3 mg/kg, i.p.), would reverse deficits observed in behavioral inhibition. RESULTS: Nf1+/- mice chose a higher percentage of smaller rewards when both 10- and 20-s delays were administered compared to WT mice, suggesting Nf1+/- mice are more impulsive. When treated with guanfacine (0.3 mg/kg, i.p.), Nf1+/- mice exhibited decreased impulsive choice by waiting for the larger, delayed reward. Nf1+/- mice also exhibited deficits in behavioral inhibition compared to WT mice in the CAR test by repetitively entering the outer edge of the platform where they risk falling. Treatment with guanfacine ameliorated these deficits. In addition, Nf1+/- mice exhibited hyperactivity as increased distance was traveled compared to WT controls in the open field. This hyperactivity in Nf1+/- mice was reduced with guanfacine pre-treatment. CONCLUSIONS: Overall, our study confirms that Nf1+/- mice exhibit deficits in behavioral inhibition in multiple contexts, a key feature of ADHD, and can be used as a model system to identify alterations in neural circuitry associated with symptoms of ADHD in children with NF1

    Randomized clinical trial of the effects of screening and brief intervention for illicit drug use: the Life Shift/Shift Gears study.

    Get PDF
    BackgroundAlthough screening, brief intervention, and referral to treatment (SBIRT) has shown promise for alcohol use, relatively little is known about its effectiveness for adult illicit drug use. This randomized controlled trial assessed the effectiveness of the SBIRT approach for outcomes related to drug use among patients visiting trauma and emergency departments (EDs) at two large, urban hospitals.MethodsA total of 700 ED patients who admitted using illegal drugs in the past 30 days were recruited, consented, provided baseline measures of substance use and related problems measured with the Addiction Severity Index-Lite (ASI-Lite), and then randomized to the Life Shift SBIRT intervention or to an attention-placebo control group focusing on driving and traffic safety (Shift Gears). Both groups received a level of motivational intervention matched to their condition and risk level by trained paraprofessional health educators. Separate measurement technicians conducted face-to-face follow-ups at 6 months post-intervention and collected hair samples to confirm reports of abstinence from drug use. The primary outcome measure of the study was past 30-day drug abstinence at 6 months post-intervention, as self-reported on the ASI-Lite.ResultsOf 700 participants, 292 (42%) completed follow-up. There were no significant differences in self-reported abstinence (12.5% vs. 12.0% , p = 0.88) for Life Shift and Shift Gears groups, respectively. When results of hair analyses were applied, the abstinence rate was 7 percent for Life Shift and 2 percent for Shift Gears (p = .074). In an analysis in which results were imputed (n = 694), there was no significant difference in the ASI-Lite drug use composite scores (Life Shift +0.005 vs. Shift Gears +0.017, p = 0.12).ConclusionsIn this randomized controlled trial, there was no evidence of effectiveness of SBIRT on the primary drug use outcome.Trial registrationClinicalTrials.gov NCT01683227

    Microwave Spectroscopy

    Get PDF
    Contains research objectives and reports on four research projects.Signal Corps Contract DA36-039-sc-7489
    corecore