623 research outputs found

    Experimental physics at JLab: Where confinement meets asymptotic freedom

    Get PDF
    Physics and technological highlights of the current and near future activities of the Italian JLab12 collaboration working at the Jefferson National Accelerator Facility are shortly summarized

    Update of High Resolution (e,e'K^+) Hypernuclear Spectroscopy at Jefferson Lab's Hall A

    Full text link
    Updated results of the experiment E94-107 hypernuclear spectroscopy in Hall A of the Thomas Jefferson National Accelerator Facility (Jefferson Lab), are presented. The experiment provides high resolution spectra of excitation energy for 12B_\Lambda, 16N_\Lambda, and 9Li_\Lambda hypernuclei obtained by electroproduction of strangeness. A new theoretical calculation for 12B_\Lambda, final results for 16N_\Lambda, and discussion of the preliminary results of 9Li_\Lambda are reported.Comment: 8 pages, 5 figures, submitted to the proceedings of Hyp-X Conferenc

    Performance of the Two Aerogel Cherenkov Detectors of the JLab Hall A Hadron Spectrometer

    Full text link
    We report on the design and commissioning of two silica aerogel Cherenkov detectors with different refractive indices. In particular, extraordinary performance in terms of the number of detected photoelectrons was achieved through an appropriate choice of PMT type and reflector, along with some design considerations. After four years of operation, the number of detected photoelectrons was found to be noticeably reduced in both detectors as a result of contamination, yellowing, of the aerogel material. Along with the details of the set-up, we illustrate the characteristics of the detectors during different time periods and the probable causes of the contamination. In particular we show that the replacement of the contaminated aerogel and parts of the reflecting material has almost restored the initial performance of the detectors.Comment: 18 pages, 9 Figures, 4 Tables, 44 Reference

    Transversity and Transverse Spin in Nucleon Structure through SIDIS at Jefferson Lab

    Full text link
    The JLab 12 GeV upgrade with a proposed solenoid detector and the CLAS12 detector can provide the granularity and three-dimensional kinematic coverage in longitudinal and transverse momentum, 0.1x0.50.1\le x \le 0.5, 0.3z0.70.3 \le z \le 0.7 with PT1.5GeVP_T \le 1.5 {\rm GeV} to precisely measure the leading twist chiral-odd and TT-odd quark distribution and fragmentation functions in SIDIS. The large xx experimental reach of these detectors with a 12 GeV CEBAF at JLab makes it {\em ideal} to obtain precise data on the {\em valence-dominated} transversity distribution function and to access the tensor charge.Comment: 7 Pages, 2 figures. Summary of the working group on Transversity and Transverse Spin Physics, from the workshop, "Inclusive and Semi-Inclusive Spin Physics with High Luminosity and LargeAcceptance at 11 GeV", Thomas Jefferson National Accelerator Facility (JLAB), December 13-14, 2006, Jefferson Lab, Newport News, VA USA. Serves as input for the Nuclear Physics Long Range Plan on QCD and Hadron Physic

    A precise extraction of the induced polarization in the 4He(e,e'p)3H reaction

    Full text link
    We measured with unprecedented precision the induced polarization Py in 4He(e,e'p)3H at Q^2 = 0.8 (GeV/c)^2 and 1.3 (GeV/c)^2. The induced polarization is indicative of reaction-mechanism effects beyond the impulse approximation. Our results are in agreement with a relativistic distorted-wave impulse approximation calculation but are over-estimated by a calculation with strong charge-exchange effects. Our data are used to constrain the strength of the spin independent charge-exchange term in the latter calculation.Comment: submitted to Physical Review Letter

    The CLAS12 large area RICH detector

    Get PDF
    Abstract A large area RICH detector is being designed for the CLAS12 spectrometer as part of the 12 GeV upgrade program of the Jefferson Lab Experimental Hall-B. This detector is intended to provide excellent hadron identification from 3 GeV/ c up to momenta exceeding 8 GeV/ c and to be able to work at the very high design luminosity-up to 10 35 cm 2 s −1 . Detailed feasibility studies are presented for two types of radiators, aerogel and liquid C 6 F 14 freon, in conjunction with a highly segmented light detector in the visible wavelength range. The basic parameters of the RICH are outlined and the resulting performances, as defined by preliminary simulation studies, are reported

    The HERMES Dual-Radiator Ring Imaging Cerenkov Detector

    Full text link
    The construction and use of a dual radiator Ring Imaging Cerenkov(RICH) detector is described. This instrument was developed for the HERMES experiment at DESY which emphasizes measurements of semi-inclusive deep-inelastic scattering. It provides particle identification for pions, kaons, and protons in the momentum range from 2 to 15 GeV, which is essential to these studies. The instrument uses two radiators, C4F10, a heavy fluorocarbon gas, and a wall of silica aerogel tiles. The use of aerogel in a RICH detector has only recently become possible with the development of clear, large homogeneous and hydrophobic aerogel. A lightweight mirror was constructed using a newly perfected technique to make resin-coated carbon-fiber surfaces of optical quality. The photon detector consists of 1934 photomultiplier tubes for each detector half, held in a soft steel matrix to provide shielding against the residual field of the main spectrometer magnet.Comment: 25 pages, 23 figure
    corecore