623 research outputs found
Experimental physics at JLab: Where confinement meets asymptotic freedom
Physics and technological highlights of the current and near future activities of the Italian JLab12 collaboration working at the Jefferson National Accelerator Facility are shortly summarized
Update of High Resolution (e,e'K^+) Hypernuclear Spectroscopy at Jefferson Lab's Hall A
Updated results of the experiment E94-107 hypernuclear spectroscopy in Hall A
of the Thomas Jefferson National Accelerator Facility (Jefferson Lab), are
presented. The experiment provides high resolution spectra of excitation energy
for 12B_\Lambda, 16N_\Lambda, and 9Li_\Lambda hypernuclei obtained by
electroproduction of strangeness. A new theoretical calculation for
12B_\Lambda, final results for 16N_\Lambda, and discussion of the preliminary
results of 9Li_\Lambda are reported.Comment: 8 pages, 5 figures, submitted to the proceedings of Hyp-X Conferenc
Performance of the Two Aerogel Cherenkov Detectors of the JLab Hall A Hadron Spectrometer
We report on the design and commissioning of two silica aerogel Cherenkov
detectors with different refractive indices. In particular, extraordinary
performance in terms of the number of detected photoelectrons was achieved
through an appropriate choice of PMT type and reflector, along with some design
considerations. After four years of operation, the number of detected
photoelectrons was found to be noticeably reduced in both detectors as a result
of contamination, yellowing, of the aerogel material. Along with the details of
the set-up, we illustrate the characteristics of the detectors during different
time periods and the probable causes of the contamination. In particular we
show that the replacement of the contaminated aerogel and parts of the
reflecting material has almost restored the initial performance of the
detectors.Comment: 18 pages, 9 Figures, 4 Tables, 44 Reference
Transversity and Transverse Spin in Nucleon Structure through SIDIS at Jefferson Lab
The JLab 12 GeV upgrade with a proposed solenoid detector and the CLAS12
detector can provide the granularity and three-dimensional kinematic coverage
in longitudinal and transverse momentum, , with to precisely measure the leading twist
chiral-odd and -odd quark distribution and fragmentation functions in SIDIS.
The large experimental reach of these detectors with a 12 GeV CEBAF at JLab
makes it {\em ideal} to obtain precise data on the {\em valence-dominated}
transversity distribution function and to access the tensor charge.Comment: 7 Pages, 2 figures. Summary of the working group on Transversity and
Transverse Spin Physics, from the workshop, "Inclusive and Semi-Inclusive
Spin Physics with High Luminosity and LargeAcceptance at 11 GeV", Thomas
Jefferson National Accelerator Facility (JLAB), December 13-14, 2006,
Jefferson Lab, Newport News, VA USA. Serves as input for the Nuclear Physics
Long Range Plan on QCD and Hadron Physic
A precise extraction of the induced polarization in the 4He(e,e'p)3H reaction
We measured with unprecedented precision the induced polarization Py in
4He(e,e'p)3H at Q^2 = 0.8 (GeV/c)^2 and 1.3 (GeV/c)^2. The induced polarization
is indicative of reaction-mechanism effects beyond the impulse approximation.
Our results are in agreement with a relativistic distorted-wave impulse
approximation calculation but are over-estimated by a calculation with strong
charge-exchange effects. Our data are used to constrain the strength of the
spin independent charge-exchange term in the latter calculation.Comment: submitted to Physical Review Letter
The CLAS12 large area RICH detector
Abstract A large area RICH detector is being designed for the CLAS12 spectrometer as part of the 12 GeV upgrade program of the Jefferson Lab Experimental Hall-B. This detector is intended to provide excellent hadron identification from 3 GeV/ c up to momenta exceeding 8 GeV/ c and to be able to work at the very high design luminosity-up to 10 35 cm 2 s −1 . Detailed feasibility studies are presented for two types of radiators, aerogel and liquid C 6 F 14 freon, in conjunction with a highly segmented light detector in the visible wavelength range. The basic parameters of the RICH are outlined and the resulting performances, as defined by preliminary simulation studies, are reported
The HERMES Dual-Radiator Ring Imaging Cerenkov Detector
The construction and use of a dual radiator Ring Imaging Cerenkov(RICH)
detector is described. This instrument was developed for the HERMES experiment
at DESY which emphasizes measurements of semi-inclusive deep-inelastic
scattering. It provides particle identification for pions, kaons, and protons
in the momentum range from 2 to 15 GeV, which is essential to these studies.
The instrument uses two radiators, C4F10, a heavy fluorocarbon gas, and a wall
of silica aerogel tiles. The use of aerogel in a RICH detector has only
recently become possible with the development of clear, large homogeneous and
hydrophobic aerogel. A lightweight mirror was constructed using a newly
perfected technique to make resin-coated carbon-fiber surfaces of optical
quality. The photon detector consists of 1934 photomultiplier tubes for each
detector half, held in a soft steel matrix to provide shielding against the
residual field of the main spectrometer magnet.Comment: 25 pages, 23 figure
- …
