56 research outputs found

    Simultaneous Image Registration and Monocular Volumetric Reconstruction of a fluid flow

    Get PDF
    We propose to combine image registration and volumetric reconstruction from a monocular video of a draining off Hele-Shaw cell filled with water. A Hele-Shaw cell is a tank whose depth is small (e.g. 1 mm) compared to the other dimensions (e.g. 400 800 mm2). We use a technique known as molecular tagging which consists in marking by photobleaching a pattern in the fluid and then tracking its deformations. The evolution of the pattern is filmed with a camera whose principal axis coincides with the depth of the cell. The velocity of the fluid along this direction is not constant. Consequently,tracking the pattern cannot be achieved with classical methods because what is observed is the integration of the marked particles over the entire depth of the cell. The proposed approach is built on top of classical direct image registration in which we incorporate a volumetric image formation model. It allows us to accurately measure the motion and the velocity profiles for the entire volume (including the depth of the cell) which is something usually hard to achieve. The results we obtain are consistent with the theoretical hydrodynamic behaviour for this flow which is known as the laminar Poiseuille flow

    Image registration algorithm for molecular tagging velocimetry applied to unsteady flow in Hele-Shaw cell

    Get PDF
    In order to develop velocimetry methods for confined geometries, we propose to combine image registration and volumetric reconstruction from a monocular video of the draining of a Hele-Shaw cell filled with water. The cell’s thickness is small compared to the other two dimensions (e.g. 1x400 x 800 mm3). We use a technique known as molecular tagging which consists in marking by photobleaching a pattern in the fluid and then tracking its deformations. The evolution of the pattern is filmed with a camera whose principal axis coincides with the cell’s gap. The velocity of the fluid along this direction is not constant. Consequently, tracking the pattern cannot be achieved with classical methods because what is observed is the integral of the marked molecules over the entire cell’s gap. The proposed approach is built on top of direct image registration that we extend to specifically model the volumetric image formation. It allows us to accurately measure the motion and the velocity profiles for the entire volume (including the cell’s gap) which is something usually hard to achieve. The results we obtained are consistent with the theoretical hydrodynamic behaviour for this flow which is known as the Poiseuille flow

    IntercorrĂ©lation d’images PIV sur GPU–application Ă  un Ă©coulement en fluide turbide

    Get PDF
    La VĂ©locimĂ©trie par Images de Particules (PIV) est une technique de mesure largement utilisĂ©e en MĂ©canique des Fluides, faisant intervenir une source Laser associĂ©e Ă  une ou plusieurs camĂ©ras. L’utilisation de capteurs matriciels de haute rĂ©solution (>= Ă  4 Mpixels) se gĂ©nĂ©ralise aussi bien pour des systĂšmes d’acquisition basse cadence (de l’ordre de quelques Hertz), que pour des systĂšmes rapides autorisant des frĂ©quences d’acquisition de plusieurs KiloHertz. Il devient dĂ©sormais usuel de gĂ©nĂ©rer des centaines de GigaOctets de donnĂ©es lors d’une Ă©tude expĂ©rimentale. Ces donnĂ©es sont ensuite traitĂ©es numĂ©riquement avec des algorithmes itĂ©ratifs de traitement d’images pour lesquels on recherche une prĂ©cision et une robustesse suffisantes. Avec des algorithmes exĂ©cutĂ©s de maniĂšre sĂ©quentielle, ce temps de traitement est largement supĂ©rieur au temps nĂ©cessaire pour l’acquisition des donnĂ©es. Nous proposons, dans cette communication, de dĂ©tailler l’algorithme d’intercorrĂ©lation d’images que nous avons portĂ© sur une architecture GPU (Graphics Processing Units), particuliĂšrement adaptĂ©e aux tĂąches de traitement d’images parallĂ©lisĂ©es. Cette application GPU, dĂ©veloppĂ©e sous CUDA, a Ă©tĂ© utilisĂ©e pour Ă©tudier la propagation d’anneaux tourbillonnaires en fluide non newtonien par PIV2D2C. L’objectif du portage sous GPU Ă©tant de rĂ©duire les temps d’exĂ©cution, le calcul de la fonction d’intercorrĂ©lation d’images normalisĂ©e (ZNCC) est effectuĂ© spatialement. Pour des dimensions conventionnelles de maille d’analyse (16ÂČ pixels par exemple), le calcul de corrĂ©lation directe sur GPU s’avĂšre plus rapide que le calcul dans l’espace spectral (par FFT) sur la mĂȘme architecture matĂ©rielle. Par rapport aux prĂ©cĂ©dentes Ă©tudes ([1], [2]), les temps spĂ©cifiques d’exĂ©cution des sous-routines seront dĂ©taillĂ©s. L’algorithme mis en Ɠuvre est multi-passe avec une dimension d’analyse dĂ©croissante. Entre chaque itĂ©ration, les mailles de calcul sont dĂ©calĂ©es symĂ©triquement en valeur dĂ©cimale afin de centrer le pic de corrĂ©lation sur la maille d’analyse [3]. Les temps de calcul, pour un couple d’images 2048x2048 pixels, sont quantifiĂ©s avec diffĂ©rentes cartes graphiques, incluant les temps de transfert mĂ©moire CPU GPU. Les temps d’exĂ©cution en fonction du nombre de cƓurs Ă©quipant les cartes sont donnĂ©s ci-dessous (tableau1). Le processus complet fait intervenir quatre itĂ©rations sur l’ensemble de l’image : 1 itĂ©ration avec un maillage original en 32ÂČ pixels suivie de 3 itĂ©rations avec un maillage final de 16ÂČ pixels. On observe des temps d’exĂ©cution dĂ©croissant en fonction du nombre de cƓurs et de l’amĂ©lioration globale des performances des architectures graphiques. Cela traduit une accĂ©lĂ©ration du traitement par intercorrĂ©lation d’images PIV. Par ailleurs, ce type de traitement peut ĂȘtre effectuĂ© en local, sans transfert de grandes quantitĂ©s de donnĂ©es ; ce qui autorise un retour rapide sur la qualitĂ© des rĂ©sultats mais Ă©galement sur la validation du nombre de champs de vitesse nĂ©cessaire Ă  la convergence des donnĂ©es statistiques Ă  extraire. Les rĂ©sultats expĂ©rimentaux sur lesquels nous proposons des tests comparatifs sont issus de l’étude du dĂ©veloppement d’un anneau tourbillonnaire en fluide non newtonien. Le dispositif expĂ©rimental est prĂ©sentĂ© sur la figure 1. L’anneau est gĂ©nĂ©rĂ© par un systĂšme cylindre-piston ( 21mm) dans une cuve de section carrĂ©e 240x240 mm2. Le cylindre est centrĂ© dans la cuve et on rĂ©alise des mesures du champ de vitesse dans un plan diamĂ©tral sur une fenĂȘtre 80x80mm2. Une visualisation par fluorescĂ©ine est proposĂ©e sur la figure 2 (gauche). La chaĂźne PIV est constituĂ©e d’un laser Quantel Nd-YAG CFR200 et d’une camĂ©ra PCO 2000 2048x2048 pixels. L’ensemencement est assurĂ© avec des particules d’Orgasol, de diamĂštre Dp=60 ”m. L’une des difficultĂ©s de ce travail expĂ©rimental provient de la turbiditĂ© des fluides utilisĂ©s (solutions de Xanthane pour obtenir un comportement non newtonien rhĂ©ofluidifiant). Celle-ci entraĂźne un rapport « signal sur bruit » des images de particules qui est trĂšs pĂ©nalisant lors du traitement PIV. La seconde des difficultĂ©s est liĂ©e Ă  l’information recherchĂ©e dans cette Ă©tude, la vorticitĂ©, qui est calculĂ©e Ă  partir des gradients de vitesse et qui nĂ©cessite donc des champs de vitesse de trĂšs bonne qualitĂ©. Les rĂ©sultats obtenus (figure 2) montrent que l’obtention des dĂ©rivĂ©es spatiales de la vitesse, particuliĂšrement sensible au bruit de mesure, reste accessible au moyen de la fonction de corrĂ©lation normalisĂ©e (ZNCC) calculĂ©e dans notre implĂ©mentation sur GPU

    Topographically induced internal solitary waves in a pycnocline: Ultrasonic probes and stereo-correlation measurements

    Get PDF
    Internal solitary waves (ISWs) are large amplitude stable waves propagating in regions of high density gradients such as the ocean pycnocline. Their dynamics has often been investigated in two-dimensional approaches, however, their three-dimensional evolution is still poorly known. Experiments have been conducted in the large stratified water tank of CNRM-GAME to study the generation of ISWs in two academic configurations inspired by oceanic regimes. First, ultrasonic probes are used to measure the interfacial displacement in the two configurations. In the primary generation case for which the two layers are of constant density, the generation of ISWs is investigated in two series of experiments with varying amplitude and forcing frequency. In the secondary generation case for which the lower layer is stratified, the generation of ISWs from the impact of an internal wave beam on the pycnocline and their subsequent dynamics is studied. The dynamics of ISWs in these two regimes accords well with analytical approaches and numerical simulations performed in analogous configurations. Then, recent developments of a stereo correlation technique are used to describe the three-dimensional structure of propagating ISWs. In the primary generation configuration, small transverse effects are observed in the course of the ISW propagation. In the secondary generation configuration, larger transverse structures are observed in the interfacial waves dynamics. The interaction between interfacial troughs and internal waves propagating in the lower stratified layer are a possible cause for the generation of these structures. The magnitude of these transverse structures is quantified with a nondimensional parameter in the two configurations. They are twice as large in the secondary generation case as in the primary generation case

    Milli-PIV rheology of shear-thinning fluids

    Get PDF
    Milli-Particle Image Velocimetry (Milli-PIV), which is an application of the standard PIV has been developed to measure the velocity distribution of complex fluids in a millimetric Hele-Shaw cell. A laser sheet is sent perpendicularly to the cell and the camera observes the PIV images via an internal optical prism. We studied, with Milli-PIV, a structural series of shear thinning xanthan fluids at different injection rates. We determined the velocity profiles in the thickness of the flow cell and discussed the accuracy of measurement. Using an inverse method, we calculated the constitutive parameters and showed that they are similar to those measured by rheology. The pressure gradient characteristic of the couple experimental conditions - fluid were also calculated from modeling the velocity profile

    VĂ©locimĂ©trie 3D par marquage molĂ©culaire et recalage d’image pour le passage d’une bulle isolĂ©e en cellule de Hele-Shaw

    Get PDF
    Cet article dĂ©crit l’application de techniques de vision par ordinateur Ă  la mesure de vitesse pour deux Ă©coulements gĂ©nĂ©rĂ©s en Cellule de Hele-Shaw (CH). Un Écoulement Laminaire de Poiseuille (ELP) est gĂ©nĂ©rĂ© par la vidange de la CH remplie d’un liquide prĂ©alablement au repos. La figure 1 donne un aperçu de la configuration expĂ©rimentale. Nous proposons un nouvel algorithme combinant le Recalage d’Image Direct (RID) et une reconstruction volumique en vision monoculaire permettant de suivre le mouvement d’un motif marquant le liquide au niveau molĂ©culaire. La mĂ©thode nous permet d’obtenir une mesure expĂ©rimentale de l’ELP dans des gĂ©omĂ©tries Ă  accĂšs optique limitĂ©. PrĂ©cĂ©demment, des mesures de vitesse de cet Ă©coulement acadĂ©mique ont principalement Ă©tĂ© obtenues pour des rĂ©gions d’intĂ©rĂȘt restreintes (1 mm3 par ”PIV (Sinton [2004])) ou sans prise en compte directe du mouvement dans la profondeur de la CH (par PIV classique (Roudet et al. [2011])). Par comparaison, notre approche nous permet de mesurer le dĂ©veloppement de l’ELP pour un volume consĂ©quent en milieu confinĂ© (ici 147×147×1 mm3). Dans un deuxiĂšme temps, nous nous intĂ©resserons Ă  la mesure de vitesse en amont d’une bulle en ascension dans une CH Ă  partir d’images gĂ©nĂ©rĂ©es numĂ©riquement. Les phĂ©nomĂšnes observĂ©s sont de nature dĂ©formable et nous cherchons Ă  faire une mesure tridimensionnelle Ă  partir d’observations 2D uniquement. Nous proposons donc une mĂ©thode reposant sur deux Ă©lĂ©ments : d’une part, une modĂ©lisation 3D du liquide et de son mouvement en CH et, d’autre part, des contraintes physiques gĂ©nĂ©rales et souples. Garbe et al. [2008] proposent une variante d’estimation classique par flot optique en intĂ©grant un modĂšle volumique pour un Ă©coulement gazeux en micro-canal. Cependant, dans Garbe et al. [2008], le modĂšle d’ELP est utilisĂ© comme un « a priori » trĂšs fort. L’article est organisĂ© de la maniĂšre suivante. Nous dĂ©crivons le dispositif expĂ©rimental et le marquage molĂ©culaire par photobleaching en §2. Notre algorithme de suivi et de reconstruction est dĂ©taillĂ© en §3. Les rĂ©sultats sont prĂ©sentĂ©s en §4. En §5, nous concluons et discutons des applications potentielles de notre travail

    Investigation of the three-dimensional turbulent near-wake structure past a flat plate by tomographic PIV at high Reynolds number

    Get PDF
    This paper reports an experimental investigation of the high-Reynolds number turbulent flow pasta thin flat plate with sharpuntapered edges,by means of tomographic PIV. The experiments,carried out in the S4 wind tunnel of IMFT, have quantified the three-dimensional coherent vortex structures, by means of 3-D Proper Orthogonal Decomposition and reconstruction. The interaction of themostenergetic coherent structures with the random turbulence is discussed. Furthermore, Proper Orthogonal Decomposition (POD), analysis allowed evaluation of three-dimensional phase-averaged dynamics that quantified the vortex shedding mechanism as well as the influence of higher modes associated with the finer-scale turbulence

    Investigation par inhibition de fluorescence des mécanismes locaux de transfert de masse en écoulement de Taylor

    Get PDF
    Dans cette Ă©tude, le transfert de masse gaz-liquide en Ă©coulement de Taylor est investiguĂ©, dans une conduite verticale de section circulaire millimĂ©trique, par les techniques de Fluorescence par Plan Laser avec Inhibition (PLIFI) et ombroscopie. Une mĂ©thode spĂ©cifique a Ă©tĂ© dĂ©veloppĂ©e pour quantifier les champs de concentration moyens en gaz dissous, donnant accĂšs Ă  l’évolution du transfert de masse en fonction du temps de prĂ©sence des bulles dans la conduite. Une correction liĂ©e Ă  la diffusion de la lumiĂšre proche des interfaces gaz-liquide a Ă©tĂ© implĂ©mentĂ©e afin de s’affranchir de ce bruit optique. La zone du film de lubrification est observĂ©e avec dĂ©tails pour extraire les profils de concentration et quantifier sĂ©parĂ©ment sa contribution au transfert de masse total, ainsi que la contribution des bouchons de liquide

    Modelling of mass transfer in Taylor flow: investigation with the PLIF-I technique

    Get PDF
    An experimental investigation of mass transfer between bubbles, slugs and lubrication films is performed by means of optical techniques for air-water Taylor flows in a 3 mm glass channel. Bubble size, shape and velocity, as well as slug size and film thickness, are measured by use of the shadowgraphy technique. The PLIF-I technique, with associated specific technical adjustments and image processing methods, gives access to the dissolved oxygen concentration in the liquid phase with high spatial and temporal resolutions. Values of concentration are measured in the slugs and, for the first time, in the lubrication films, leading to the quantification of mass transfer contributions from caps and from the central bubble body. Results for overall mass transfer are compared to literature models based on volumetric coefficient kLa. Among them the model proposed by Van Baten and Krishna (2004), which considers cap and film contributions to kLa. They are found to fail to accurately predict the experimental data of average O2 concentration in the liquid phase for short slugs (Ls < 2dc). An improved version of this model is proposed, allowing calculation of O2 concentration for films and slugs along the channel. The model needs flow characteristics, which are obtained by shadowgraphy

    A stereoscopic method for rapid monitoring of the spatio- temporal evolution of the sand-bed elevation in the swash zone.

    Get PDF
    A stereoscopic technique is developed in order to measure the sand-bed elevation in the swash zone at thewave time-scale. The present technique allows one to perform highly resolved measurements both in time and in space. An accuracy and a precision of less than 300 ÎŒm and 600 ÎŒm, respectively, are obtained in each direction. This technique has been used during a large-scale wave flume experiment where an erosive process of a plane beach is studied. The stereoscopic technique allows one to accurately measure the long-term evolution of the beach profile. In addition, spatially dependent variability on shorten time-scales is observed featuring accretion as well as erosion at the wave time-scale
    • 

    corecore