322 research outputs found
Radon Emanation Techniques and Measurements for LZ
Radon emanation was projected to account for % of the electron recoil
background in the WIMP region of interest for the LUX-ZEPLIN (LZ) experiment.
To mitigate the amount of radon inside the detector volume, materials with
inherently low radioactivity content were selected for LZ construction through
an extensive screening campaign. The SD Mines radon emanation system was one of
four emanation facilities utilized to screen materials during construction of
LZ. SD Mines also employed a portable radon collection system for equipment too
large or delicate to move to a radon emanation facility. This portable system
was used to assay the Inner Cryostat Vessel in-situ at various stages of
detector construction, resulting in the inference that the titanium cryostat is
the source of significant radon emanation. Assays of a Th source
confirmed that its Rn emanation is low enough for it to be used, and
that 14% of the Rn emanates from the source at room temperature.Comment: 6 pages, 4 figures, submitted to LRT 2022 Conference Proceeding
Classical-quantum correspondence in electron-positron pair creation
We examine the creation of electron-positron pairs in a very strong force field. Using numerical solutions to quantum field theory we calculate the spatial and momentum probability distributions for the created particles. A comparison with classical mechanical phase space calculations suggests that despite the fully relativistic and quantum mechanical nature of the matter creation process, most aspects can be reproduced accurately in terms of classical mechanics
The CUORE Cryostat: A 1-Ton Scale Setup for Bolometric Detectors
The cryogenic underground observatory for rare events (CUORE) is a 1-ton
scale bolometric experiment whose detector consists of an array of 988 TeO2
crystals arranged in a cylindrical compact structure of 19 towers. This will be
the largest bolometric mass ever operated. The experiment will work at a
temperature around or below 10 mK. CUORE cryostat consists of a cryogen-free
system based on pulse tubes and a custom high power dilution refrigerator,
designed to match these specifications. The cryostat has been commissioned in
2014 at the Gran Sasso National Laboratories and reached a record temperature
of 6 mK on a cubic meter scale. In this paper, we present results of CUORE
commissioning runs. Details on the thermal characteristics and cryogenic
performances of the system will be also given.Comment: 7 pages, 2 figures, LTD16 conference proceedin
The CUORE cryostat: an infrastructure for rare event searches at millikelvin temperatures
The CUORE experiment is the world's largest bolometric experiment. The
detector consists of an array of 988 TeO2 crystals, for a total mass of 742 kg.
CUORE is presently taking data at the Laboratori Nazionali del Gran Sasso,
Italy, searching for the neutrinoless double beta decay of 130Te. A large
custom cryogen-free cryostat allows reaching and maintaining a base temperature
of about 10 mK, required for the optimal operation of the detector. This
apparatus has been designed in order to achieve a low noise environment, with
minimal contribution to the radioactive background for the experiment. In this
paper, we present an overview of the CUORE cryostat, together with a
description of all its sub-systems, focusing on the solutions identified to
satisfy the stringent requirements. We briefly illustrate the various phases of
the cryostat commissioning and highlight the relevant steps and milestones
achieved each time. Finally, we describe the successful cooldown of CUORE
Validation of techniques to mitigate copper surface contamination in CUORE
In this article we describe the background challenges for the CUORE
experiment posed by surface contamination of inert detector materials such as
copper, and present three techniques explored to mitigate these backgrounds.
Using data from a dedicated test apparatus constructed to validate and compare
these techniques we demonstrate that copper surface contamination levels better
than 10E-07 - 10E-08 Bq/cm2 are achieved for 238U and 232Th. If these levels
are reproduced in the final CUORE apparatus the projected 90% C.L. upper limit
on the number of background counts in the region of interest is 0.02-0.03
counts/keV/kg/y depending on the adopted mitigation technique.Comment: 10 pages, 6 figures, 6 table
CUORE and beyond: bolometric techniques to explore inverted neutrino mass hierarchy
The CUORE (Cryogenic Underground Observatory for Rare Events) experiment will
search for neutrinoless double beta decay of Te. With 741 kg of TeO
crystals and an excellent energy resolution of 5 keV (0.2%) at the region of
interest, CUORE will be one of the most competitive neutrinoless double beta
decay experiments on the horizon. With five years of live time, CUORE projected
neutrinoless double beta decay half-life sensitivity is y
at ( y at the 90% confidence level), which
corresponds to an upper limit on the effective Majorana mass in the range
40--100 meV (50--130 meV). Further background rejection with auxiliary light
detector can significantly improve the search sensitivity and competitiveness
of bolometric detectors to fully explore the inverted neutrino mass hierarchy
with Te and possibly other double beta decay candidate nuclei.Comment: Submitted to the Proceedings of TAUP 2013 Conferenc
Exploring the Neutrinoless Double Beta Decay in the Inverted Neutrino Hierarchy with Bolometric Detectors
Neutrinoless double beta decay (0nubb) is one of the most sensitive probes
for physics beyond the Standard Model, providing unique information on the
nature of neutrinos. In this paper we review the status and outlook for
bolometric 0nubb decay searches. We summarize recent advances in background
suppression demonstrated using bolometers with simultaneous readout of heat and
light signals. We simulate several configurations of a future CUORE-like
bolometer array which would utilize these improvements and present the
sensitivity reach of a hypothetical next-generation bolometric 0nubb
experiment. We demonstrate that a bolometric experiment with the isotope mass
of about 1 ton is capable of reaching the sensitivity to the effective Majorana
neutrino mass (|mee|) of order 10-20 meV, thus completely exploring the
so-called inverted neutrino mass hierarchy region. We highlight the main
challenges and identify priorities for an R&D program addressing them.Comment: 22 pages, 15 figures, submitted to EPJ
Search for Neutrinoless Double-Beta Decay of Te with CUORE-0
We report the results of a search for neutrinoless double-beta decay in a
9.8~kgyr exposure of Te using a bolometric detector array,
CUORE-0. The characteristic detector energy resolution and background level in
the region of interest are FWHM and ~counts/(keVkgyr), respectively. The
median 90%~C.L. lower-limit sensitivity of the experiment is and surpasses the sensitivity of previous searches. We find
no evidence for neutrinoless double-beta decay of Te and place a
Bayesian lower bound on the decay half-life, ~ at 90%~C.L. Combining CUORE-0 data with the 19.75~kgyr
exposure of Te from the Cuoricino experiment we obtain at 90%~C.L.~(Bayesian), the most stringent
limit to date on this half-life. Using a range of nuclear matrix element
estimates we interpret this as a limit on the effective Majorana neutrino mass,
-- .Comment: 6 pages, 5 figures, updated version as published in PR
- …