205 research outputs found

    Piezoelectrically Driven Thermoacoustic Refrigerator

    Get PDF
    Thermoacoustic refrigeration is an emerging refrigeration technology which does not require any moving parts or harmful refrigerants in its operation. This technology uses acoustic waves to pump heat across a temperature gradient. The vast majority of thermoacoustic refrigerators to date have used electromagnetic loudspeakers to generate the acoustic input. In this thesis, the design, construction, operation, and modeling of a piezoelectrically-driven thermoacoustic refrigerator are detailed. This refrigerator demonstrates the effectiveness of piezoelectric actuation in moving 0.3 W of heat across an 18 degree C temperature difference with an input power of 7.6 W. The performance characteristics of this class of thermoacoustic-piezoelectric refrigerators are modeled by using DeltaEC software and the predictions are experimentally validated. The obtained results confirm the validity of the developed model. Furthermore, the potential of piezoelectric actuation as effective means for driving thermoacoustic refrigerators is demonstrated as compared to the conventional electromagnetic loudspeakers which are heavy and require high actuation energy. The developed theoretical and experimental tools can serve as invaluable means for the design and testing of other piezoelectrically-driven thermoacoustic refrigerator configurations

    Faithful Education and Healthy Community: Some Thoughts on Education for a Kingdom Perspective

    Get PDF

    Removal of branched dibenzothiophenes from hydrocarbon mixtures via charge transfer complexes with a TAPA-functionalized adsorbent

    Get PDF
    A process for producing an adsorbent where a metal oxide is reacted with an alkoxy silane to produce an epoxy-functionalized metal oxide. This product is reacted with an amino-substituted propionic acid and a nitro-substituted fluorenone, and this product is grafted to the epoxy-functionalized metal oxide. This grafted product is the adsorbent, which may be contacted with a hydrocarbon mixture having at least one sulfur containing compound in order to remove this sulfur containing compound. Also disclosed is a process for adding polymerization groups to an adsorbent

    Ultra-broadband wavelength-swept Tm-doped fiber laser using wavelength-combined gain stages

    Get PDF
    A wavelength-swept thulium-doped fiber laser system employing two parallel cavities with two different fiber gain stages is reported. The fiber gain stages were tailored to provide emission in complementary bands with external wavelength-dependent feedback cavities sharing a common rotating polygon mirror for wavelength scanning. The wavelength-swept laser outputs from the fiber gain elements were spectrally combined by means of a dichroic mirror and yielded over 500 mW of output with a scanning range from ~1740 nm to ~2070 nm for a scanning frequency of ~340 Hz

    Adsorption of dibenzothiophenes from hydrocarbon and model diesel feeds

    Get PDF
    A process for adsorbing aromatic sulfur compounds, where an adsorbent is contacted with a C.sub.6-C.sub.20 aromatic and/or aliphatic stream which comprises a solution of (i) at least one benzothiophene compound, (ii) a solvent which comprises at least one C.sub.6-C.sub.16 aliphatic compound, and (iii) optionally at least one C.sub.6-C.sub.12 aromatic compound. In this process, the adsorbent is regenerated using an organic regenerant such as, but not limited to, toluene. Also disclosed is another process for adsorbing aromatic sulfur compounds. In this process, an adsorbent is contacted with a mixture comprising a model diesel feed comprising at least one benzothiophene compound. In this process, the adsorbent is regenerated using an organic regenerant such as, but not limited to, toluene

    Wavelength-swept Tm-doped fiber laser operating in the two-micron wavelength band

    Get PDF
    A wavelength-swept thulium-doped silica fiber laser using an intracavity rotating slotted-disk wavelength scanning filter in combination with an intracavity solid etalon for passive control of temporal and spectral profiles is reported. The laser yielded a wavelength swept output in a step-wise fashion with each laser pulse separated from the previous pulse by a frequency interval equal to the free-spectral-range of the etalon and with an instantaneous linewidth of <0.05 nm. Scanning ranges from 1905 nm to 2049 nm for a cladding-pumping laser configuration, and from 1768 nm to 1956 nm for a core-pumping laser configuration were achieved at average output powers up to ~1 W

    Safety Recommendations for Evaluation and Surgery of the Head and Neck During the COVID-19 Pandemic

    Get PDF
    Importance The rapidly expanding novel coronavirus disease 2019 (COVID-19) pandemic, caused by severe acute respiratory syndrome coronavirus 2, has challenged the medical community to an unprecedented degree. Physicians and health care workers are at added risk of exposure and infection during the course of patient care. Because of the rapid spread of this disease through respiratory droplets, health care workers who come in close contact with the upper aerodigestive tract during diagnostic and therapeutic procedures, such as otolaryngologists–head and neck surgeons, are particularly at risk. A set of safety recommendations was created based on a review of the literature and communications with physicians with firsthand knowledge of safety procedures during the COVID-19 pandemic. Observations A high number of health care workers were infected during the first phase of the pandemic in the city of Wuhan, China. Subsequently, by adopting strict safety precautions, other regions were able to achieve high levels of safety for health care workers without jeopardizing the care of patients. The most common procedures related to the examination and treatment of upper aerodigestive tract diseases were reviewed. Each category was reviewed based on the potential risk imposed to health care workers. Specific recommendations were made based on the literature, when available, or consensus best practices. Specific safety recommendations were made for performing tracheostomy in patients with COVID-19. Conclusions and Relevance Preserving a highly skilled health care workforce is a top priority for any community and health care system. Based on the experience of health care systems in Asia and Europe, by following strict safety guidelines, the risk of exposure and infection of health care workers could be greatly reduced while providing high levels of care. The provided recommendations, which may evolve over time, could be used as broad guidance for all health care workers who are involved in the care of patients with COVID-19

    Pancreatic ductal adenocarcinoma cell secreted extracellular vesicles containing ceramide-1-phosphate promote pancreatic cancer stem cell motility

    Get PDF
    The high mortality rate associated with pancreatic ductal adenocarcinoma (PDAC) is in part due to lack of effective therapy for this highly chemoresistant tumor. Cancer stem cells, a subset of cancer cells responsible for tumor initiation and metastasis, are not targeted by conventional cytotoxic agents, which renders the identification of factors that facilitate cancer stem cell activation useful in defining targetable mechanisms. We determined that bioactive sphingolipid induced migration of pancreatic cancer stem cells (PCSC) and signaling was specific to ceramide-1-phosphate (C1P). Furthermore, PDAC cells were identified as a rich source of C1P. Importantly, PDAC cells express the C1P converting enzyme ceramide kinase (CerK), secrete C1P-containing extracellular vesicles that mediate PCSC migration, and when co-injected with PCSC reduce animal survival in a PDAC peritoneal dissemination model. Our findings suggest that PDAC secrete C1P-containing extracellular vesicles as a means of recruiting PCSC to sustain tumor growth therefore making C1P release a mechanism that could facilitate tumor progression
    • …
    corecore