287 research outputs found

    Is rat a good model for assessment of particulate-based taste-masked formulations?

    Get PDF
    Recently there has been an increased interest to develop specialised dosage forms that are better suited to specific patient populations, such as paediatrics and geriatrics. In these patient populations the acceptability of the oral dosage form can be paramount to the products success. However, many active pharmaceutical Ingredients (APIs) are known to cause an aversive taste response. One way to increase the acceptability and to enhance the palatability of the formulation is to design coated taste-masked particulate-based dosage forms. The masking of poorly tasting drugs with physical barriers such as polymer coatings can be utilised to prevent the release of drug within the oral cavity, thus preventing a taste response. However, currently, there are few assessment tools and models available to test the efficiency of these particulate-based taste-masked formulations. The rat brief access taste aversion model has been shown to be useful in assessment of taste for liquid dosage forms. However, the applicability of the rat model for particulate-based taste masked formulations is yet to be assessed. It is not understood whether dissolution, solubility and thus exposure of the drug to taste receptors would be the same in rat and human. Therefore, rat saliva must be compared to human saliva to determine the likelihood that drug release would be similar within the oral cavity for both species. In this study rat saliva was characterised for parameters known to be important for drug dissolution, such as pH, buffer capacity, surface tension, and viscosity. Subsequently dissolution of model bitter tasting compounds, sildenafil citrate and efavirenz, in rat saliva was compared to dissolution in human saliva. For all parameters characterised and for the dissolution of both drugs in rat saliva, a substantial difference was observed when compared to human saliva. This discrepancy in saliva parameters and dissolution of model drugs suggests that preclinical taste evaluation of particulate-based taste-masked formulations suggests rat is not a good model for predicting taste of solid dosage forms or undissolved drug where dissolution is required. Alternative preclinical in vivo models in other species, or improved biorelevant in vitro models should be considered instead

    A cryogenic rotation stage with a large clear aperture for the half-wave plates in the Spider instrument

    Get PDF
    We describe the cryogenic half-wave plate rotation mechanisms built for and used in Spider, a polarization-sensitive balloon-borne telescope array that observed the Cosmic Microwave Background at 95 GHz and 150 GHz during a stratospheric balloon flight from Antarctica in January 2015. The mechanisms operate at liquid helium temperature in flight. A three-point contact design keeps the mechanical bearings relatively small but allows for a large (305 mm) diameter clear aperture. A worm gear driven by a cryogenic stepper motor allows for precise positioning and prevents undesired rotation when the motors are depowered. A custom-built optical encoder system monitors the bearing angle to an absolute accuracy of +/- 0.1 degrees. The system performed well in Spider during its successful 16 day flight.Comment: 11 pages, 7 figures, Published in Review of Scientific Instruments. v2 includes reviewer changes and longer literature revie

    Pointing control for the SPIDER balloon-borne telescope

    Full text link
    We present the technology and control methods developed for the pointing system of the SPIDER experiment. SPIDER is a balloon-borne polarimeter designed to detect the imprint of primordial gravitational waves in the polarization of the Cosmic Microwave Background radiation. We describe the two main components of the telescope's azimuth drive: the reaction wheel and the motorized pivot. A 13 kHz PI control loop runs on a digital signal processor, with feedback from fibre optic rate gyroscopes. This system can control azimuthal speed with < 0.02 deg/s RMS error. To control elevation, SPIDER uses stepper-motor-driven linear actuators to rotate the cryostat, which houses the optical instruments, relative to the outer frame. With the velocity in each axis controlled in this way, higher-level control loops on the onboard flight computers can implement the pointing and scanning observation modes required for the experiment. We have accomplished the non-trivial task of scanning a 5000 lb payload sinusoidally in azimuth at a peak acceleration of 0.8 deg/s2^2, and a peak speed of 6 deg/s. We can do so while reliably achieving sub-arcminute pointing control accuracy.Comment: 20 pages, 12 figures, Presented at SPIE Ground-based and Airborne Telescopes V, June 23, 2014. To be published in Proceedings of SPIE Volume 914

    MSH3 polymorphisms and protein levels affect CAG repeat instability in huntington's disease mice

    Get PDF
    Expansions of trinucleotide CAG/CTG repeats in somatic tissues are thought to contribute to ongoing disease progression through an affected individual's life with Huntington's disease or myotonic dystrophy. Broad ranges of repeat instability arise between individuals with expanded repeats, suggesting the existence of modifiers of repeat instability. Mice with expanded CAG/CTG repeats show variable levels of instability depending upon mouse strain. However, to date the genetic modifiers underlying these differences have not been identified. We show that in liver and striatum the R6/1 Huntington's disease (HD) (CAG)~100 transgene, when present in a congenic C57BL/6J (B6) background, incurred expansion-biased repeat mutations, whereas the repeat was stable in a congenic BALB/cByJ (CBy) background. Reciprocal congenic mice revealed the Msh3 gene as the determinant for the differences in repeat instability. Expansion bias was observed in congenic mice homozygous for the B6 Msh3 gene on a CBy background, while the CAG tract was stabilized in congenics homozygous for the CBy Msh3 gene on a B6 background. The CAG stabilization was as dramatic as genetic deficiency of Msh2. The B6 and CBy Msh3 genes had identical promoters but differed in coding regions and showed strikingly different protein levels. B6 MSH3 variant protein is highly expressed and associated with CAG expansions, while the CBy MSH3 variant protein is expressed at barely detectable levels, associating with CAG stability. The DHFR protein, which is divergently transcribed from a promoter shared by the Msh3 gene, did not show varied levels between mouse strains. Thus, naturally occurring MSH3 protein polymorphisms are modifiers of CAG repeat instability, likely through variable MSH3 protein stability. Since evidence supports that somatic CAG instability is a modifier and predictor of disease, our data are consistent with the hypothesis that variable levels of CAG instability associated with polymorphisms of DNA repair genes may have prognostic implications for various repeat-associated diseases

    Direct detection and measurement of wall shear stress using a filamentous bio-nanoparticle

    Get PDF
    The wall shear stress (WSS) that a moving fluid exerts on a surface affects many processes including those relating to vascular function. WSS plays an important role in normal physiology (e.g. angiogenesis) and affects the microvasculature's primary function of molecular transport. Points of fluctuating WSS show abnormalities in a number of diseases; however, there is no established technique for measuring WSS directly in physiological systems. All current methods rely on estimates obtained from measured velocity gradients in bulk flow data. In this work, we report a nanosensor that can directly measure WSS in microfluidic chambers with sub-micron spatial resolution by using a specific type of virus, the bacteriophage M13, which has been fluorescently labeled and anchored to a surface. It is demonstrated that the nanosensor can be calibrated and adapted for biological tissue, revealing WSS in micro-domains of cells that cannot be calculated accurately from bulk flow measurements. This method lends itself to a platform applicable to many applications in biology and microfluidics

    International Guideline on Dose Prioritization and Acceptance Criteria in Radiation Therapy Planning for Nasopharyngeal Carcinoma

    Get PDF
    Purpose: The treatment of nasopharyngeal carcinoma requires high radiation doses. The balance of the risks of local recurrence owing to inadequate tumor coverage versus the potential damage to the adjacent organs at risk (OARs) is of critical importance. With advancements in technology, high target conformality is possible. Nonetheless, to achieve the best possible dose distribution, optimal setting of dose targets and dose prioritization for tumor volumes and various OARs is fundamental. Radiation doses should always be guided by the As Low As Reasonably Practicable principle. There are marked variations in practice. This study aimed to develop a guideline to serve as a global practical reference. Methods and Materials: A literature search on dose tolerances and normal-tissue complications after treatment for nasopharyngeal carcinoma was conducted. In addition, published guidelines and protocols on dose prioritization and constraints were reviewed. A text document and preliminary set of variants was circulated to a panel of international experts with publications or extensive experience in the field. An anonymized voting process was conducted to rank the proposed variants. A summary of the initial voting and different opinions expressed by members were then recirculated to the whole panel for review and reconsideration. Based on the comments of the panel, a refined second proposal was recirculated to the same panel. The current guideline was based on majority voting after repeated iteration for final agreement. Results: Variation in opinion among international experts was repeatedly iterated to develop a guideline describing appropriate dose prioritization and constraints. The percentage of final agreement on the recommended parameters and alternative views is shown. The rationale for the recommendations and the limitations of current evidence are discussed. Conclusions: Through this comprehensive review of available evidence and interactive exchange of vast experience by international experts, a guideline was developed to provide a practical reference for setting dose prioritization and acceptance criteria for tumor volumes and OARs. The final decision on the treatment prescription should be based on the individual clinical situation and the patient's acceptance of optimal balance of risk. (C) 2019 Elsevier Inc. All rights reserved

    Expert consensus and recommendations on safety criteria for active mobilization of mechanically ventilated critically ill adults

    Get PDF
    Introduction: The aim of this study was to develop consensus recommendations on safety parameters for mobilizing adult, mechanically ventilated, intensive care unit (ICU) patients. Methods: A systematic literature review was followed by a meeting of 23 multidisciplinary ICU experts to seek consensus regarding the safe mobilization of mechanically ventilated patients. Results: Safety considerations were summarized in four categories: respiratory, cardiovascular, neurological and other. Consensus was achieved on all criteria for safe mobilization, with the exception being levels of vasoactive agents. Intubation via an endotracheal tube was not a contraindication to early mobilization and a fraction of inspired oxygen less than 0.6 with a percutaneous oxygen saturation more than 90% and a respiratory rate less than 30 breaths/minute were considered safe criteria for in- and out-of-bed mobilization if there were no other contraindications. At an international meeting, 94 multidisciplinary ICU clinicians concurred with the proposed recommendations. Conclusion: Consensus recommendations regarding safety criteria for mobilization of adult, mechanically ventilated patients in the ICU have the potential to guide ICU rehabilitation whilst minimizing the risk of adverse events
    corecore