333 research outputs found

    An Act of Kindness

    Get PDF
    This is a piece that was presented at the convocation of thanks, an annual ceremony in which we show our appreciation to the families of the individuals who donated their bodies to our anatomy class. It discusses how the Jewish concept of “chesed shel emet, performing a “true act of kindness, applies to the priceless gift these people gave us

    The influence of liver dysfunction on cyclosporine pharmacokinetics -A comparison between 70 per cent hepatectomy and complete bile duct ligation in dogs-

    Get PDF
    The influence of experimentally induced hepatic dysfunction on the pharmacokinetics of Cyclosporine A (CsA) was determined in dogs. The pharmacokinetics of oral (PO) and intravenous (IV) CsA were studied before and after 70 per cent hepatectomy or complete bile duct ligation (CBDL). Changes in liver function were monitored by serial measurements of serum bilirubin, and by the maximum removal rate (Rmax) and plasma disappearance rate (ICG-K) of indocyanine green (ICG). Concentrations of CsA in whole blood were measured by HPLC. Seventy per cent hepatectomy caused significant liver dysfunction: the ICG-Rmax decreased by 47.7±7.1 per cent (mean±SD) and the ICG-K decreased by 61.3±9.7 per cent during the first week after hepatectomy. At the same time, the systemic clearance (CLs) of IV-CsA decreased by 43.9±8.2 per cent, the area under the concentration curve (AUC) of IV-CsA increased by 35.4±20.8 per cent and the bioavailability of CsA decreased by 26.4±14.8 per cent. CBDL also induced significant liver dysfunction: the ICG-Rmax decreased by 39.1±12.8 per cent and the ICG-K decreased by 65.6±3.6 per cent in the second week after the operation. During the same period, the AUC of PO-CsA decreased by 69.9±10.7 per cent and the bioavailability of CsA also decreased markedly by 73.9±15.6 per cent. These data indicate that hepatic impairment significantly influences the pharmacokinetics of CsA, not only by the changes in intestinal absorption, but also by those in hepatic, metabolism. Dose adjustment is therefore necessary in the presence of hepatic dysfunction in order to maintain an adequate blood concentration of CsA without causing side effects. © 1989 The Japan Surgical Society

    Massive Empyema Associated With Transient Hypogammaglobulinemia of Infancy and IgA Deficiency

    Get PDF
    Transient hypogammaglobulinemia of infancy (THI) is originally defined as a physiological maturation defect of immunoglobulin G (IgG) production that occurs at 3-6 months of age and lasts until 18 to 36 months of age. We report here on a 22-month-old child with THI and IgA deficiency, who had massive pneumococcal empyema. Her depressed IgG level returned to normal within 6 months, but IgA level was still low at 6 yr of age. Although THI is an age-dependent and self-limiting disorder, severe infection that includes an atypical presentation of an infection may occur in some patients and this requires evaluation with immunologic study

    Mouse phenotyping with near-infrared fluorescence lymphatic imaging

    Get PDF
    We demonstrate the ability to non-invasively and quantitatively image lymphatic architecture and contractile function using dynamic near-infrared (NIR) fluorescence imaging with injection of indocyanine green in normal and transgenic mice. Unlike normal mice, which showed well defined lymphatic drainage patterns and orthograde propagation of contraction waves, we observed tortuous and mispatterned lymphatic vessels and persistent retrograde lymph flow in mice with deficiency in Prox1, a transcription factor essential for lymphatic vascular development. NIR fluorescence imaging provides a method for quantifying lymphatic function for future studies designed to discern differences in lymphatic function in murine models of human lymphatic disease

    A simple method for in vivo labelling of infiltrating leukocytes in the mouse retina using indocyanine green dye

    Get PDF
    We have developed a method to label and image myeloid cells infiltrating the mouse retina and choroid in vivo, using a single depot injection of indocyanine green dye (ICG). This was demonstrated using the following ocular models of inflammation and angiogenesis: endotoxin-induced uveitis, experimental autoimmune uveoretinitis and laser-induced choroidal neovascularization model. A near-infrared scanning ophthalmoscope was used for in vivo imaging of the eye, and flow cytometry was used on blood and spleen to assess the number and phenotype of labelled cells. ICG was administered 72 h before the induction of inflammation to ensure clearance from the systemic circulation. We found that in vivo intravenous administration failed to label any leukocytes, whereas depot injection, either intraperitoneal or subcutaneous, was successful in labelling leukocytes infiltrating into the retina. Progression of inflammation in the retina could be traced over a period of 14 days following a single depot injection of ICG. Additionally, bright-field microscopy, spectrophotometry and flow cytometric analysis suggest that the predominant population of cells stained by ICG are circulating myeloid cells. The translation of this approach into clinical practice would enable visualization of immune cells in situ. This will not only provide a greater understanding of pathogenesis, monitoring and assessment of therapy in many human ocular diseases but might also open the ability to image immunity live for neurodegenerative disorders, cardiovascular disease and systemic immune-mediated disorders

    Blood volume measurement with indocyanine green pulse spectrophotometry: dose and site of dye administration

    Get PDF
    (1) To determine the optimal administration site and dose of indocyanine green (ICG) for blood volume measurement using pulse spectrophotometry, (2) to assess the variation in repeated blood volume measurements for patients after subarachnoid hemorrhage and (3) to evaluate the safety and efficacy of this technique in patients who were treated for an intracranial aneurysm. Four repeated measurements of blood volume (BV) were performed in random order of bolus dose (10 mg or 25 mg ICG) and venous administration site (peripheral or central) in eight patients admitted for treatment of an intracranial aneurysm. Another five patients with subarachnoid hemorrhage underwent three repeated BV measurements with 25 mg ICG at the same administration site to assess the coefficient of variation. The mean +/- SD in BV was 4.38 +/- 0.88 l (n = 25) and 4.69 +/- 1.11 l (n = 26) for 10 mg and 25 mg ICG, respectively. The mean +/- SD in BV was 4.59 +/- 1.15 l (n = 26) and 4.48 +/- 0.86 l (n = 25) for central and peripheral administration, respectively. No significant difference was found. The coefficient of variance of BV measurement with 25 mg of ICG was 7.5% (95% CI: 3-12%). There is no significant difference between intravenous administration of either 10 or 25 mg ICG, and this can be injected through either a peripheral or central venous catheter. The 7.5% coefficient of variation in BV measurements determines the detectable differences using ICG pulse spectrophotometr

    Intradermal Indocyanine Green for In Vivo Fluorescence Laser Scanning Microscopy of Human Skin: A Pilot Study

    Get PDF
    BACKGROUND: In clinical diagnostics, as well as in routine dermatology, the increased need for non-invasive diagnosis is currently satisfied by reflectance laser scanning microscopy. However, this technique has some limitations as it relies solely on differences in the reflection properties of epidermal and dermal structures. To date, the superior method of fluorescence laser scanning microscopy is not generally applied in dermatology and predominantly restricted to fluorescein as fluorescent tracer, which has a number of limitations. Therefore, we searched for an alternative fluorophore matching a novel skin imaging device to advance this promising diagnostic approach. METHODOLOGY/PRINCIPAL FINDINGS: Using a Vivascope®-1500 Multilaser microscope, we found that the fluorophore Indocyanine-Green (ICG) is well suited as a fluorescent marker for skin imaging in vivo after intradermal injection. ICG is one of few fluorescent dyes approved for use in humans. Its fluorescence properties are compatible with the application of a near-infrared laser, which penetrates deeper into the tissue than the standard 488 nm laser for fluorescein. ICG-fluorescence turned out to be much more stable than fluorescein in vivo, persisting for more than 48 hours without significant photobleaching whereas fluorescein fades within 2 hours. The well-defined intercellular staining pattern of ICG allows automated cell-recognition algorithms, which we accomplished with the free software CellProfiler, providing the possibility of quantitative high-content imaging. Furthermore, we demonstrate the superiority of ICG-based fluorescence microscopy for selected skin pathologies, including dermal nevi, irritant contact dermatitis and necrotic skin. CONCLUSIONS/SIGNIFICANCE: Our results introduce a novel in vivo skin imaging technique using ICG, which delivers a stable intercellular fluorescence signal ideal for morphological assessment down to sub-cellular detail. The application of ICG in combination with the near infrared laser opens new ways for minimal-invasive diagnosis and monitoring of skin disorders
    • …
    corecore