302 research outputs found

    Strong light-matter coupling in bulk GaN-microcavities with double dielectric mirrors fabricated by two different methods

    Get PDF
    Two routes for the fabrication of bulk GaN microcavities embedded between two dielectric mirrors are described, and the optical properties of the microcavities thus obtained are compared. In both cases, the GaN active layer is grown by molecular beam epitaxy on (111) Si, allowing use of selective etching to remove the substrate. In the first case, a three period Al0.2Ga0.8N / AlN Bragg mirror followed by a lambda/2 GaN cavity are grown directly on the Si. In the second case, a crack-free 2,mu m thick GaN layer is grown, and progressively thinned to a final thickness of lambda. Both devices work in the strong coupling regime at low temperature, as evidenced by angle-dependent reflectivity or transmission experiments. However, strong light-matter coupling in emission at room temperature is observed only for the second one. This is related to the poor optoelectronic quality of the active layer of the first device, due to its growth only 250 nm above the Si substrate and its related high defect density. The reflectivity spectra of the microcavities are well accounted for by using transfer matrix calculations. (C) 2010 American Institute of Physics. [doi:10.1063/1.3477450

    Voltage controlled terahertz transmission through GaN quantum wells

    Full text link
    We report measurements of radiation transmission in the 0.220--0.325 THz frequency domain through GaN quantum wells grown on sapphire substrates at room and low temperatures. A significant enhancement of the transmitted beam intensity with the applied voltage on the devices under test is found. For a deeper understanding of the physical phenomena involved, these results are compared with a phenomenological theory of light transmission under electric bias relating the transmission enhancement to changes in the differential mobility of the two-dimensional electron gas

    Does community-based education increase students' motivation to practice community health care? - a cross sectional study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Community-based education has been introduced in many medical schools around the globe, but evaluation of instructional quality has remained a critical issue. Community-based education is an approach that aims to prepare students for future professional work at the community level. Instructional quality should be measured based on a program's outcomes. However, the association between learning activities and students' attitudes is unknown. The purpose of this study was to clarify what learning activities affect students' attitudes toward community health care.</p> <p>Methods</p> <p>From 2003 to 2009, self-administered pre- and post-questionnaire surveys were given to 693 fifth-year medical students taking a 2-week clinical clerkship. Main items measured were student attitudes, which were: "I think practicing community health care is worthwhile" ("worthwhile") and "I am confident about practicing community health care" ("confidence") using a visual analogue scale (0-100). Other items were gender, training setting, and learning activities. We analyzed the difference in attitudes before and after the clerkships by paired <it>t </it>test and the factors associated with a positive change in attitude by logistic regression analysis.</p> <p>Results</p> <p>Six hundred forty-five students (93.1%), 494 (76.6%) male and 151(23.4%) female, completed the pre- and post-questionnaires. The VAS scores of the students' attitudes for "worthwhile" and "confidence" after the clerkship were 80.2 ± 17.4 and 57.3 ± 20.1, respectively. Both of the scores increased after the clerkship. Using multivariate logistic regression analysis, "health education" was associated with a positive change for both attitudes of "worthwhile" (adjusted RR: 1.71, 95% CI: 1.10-2.66) and "confidence" (1.56, 1.08-2.25).</p> <p>Conclusions</p> <p>Community-based education motivates students to practice community health care. In addition, their motivation is increased by the health education activity. Participating in this activity probably produces a positive effect and improves the instructional quality of the program based on its outcomes.</p

    Clinical practice guidelines for the management of non-specific low back pain in primary care: an updated overview

    Get PDF
    Objective: The aim of this study was to provide an overview of the recommendations regarding the diagnosis and treatment contained in current clinical practice guidelines for patients with non-specific low back pai

    Gate current analysis of AlGaN/GaN on silicon heterojunction transistors at the nanoscale

    Get PDF
    The gate leakage current of AlGaN/GaN (on silicon)high electron mobility transistor(HEMT) is investigated at the micro and nanoscale. The gate current dependence (25-310 °C) on the temperature is used to identify the potential conduction mechanisms, as trap assisted tunneling or field emission. The conductive atomic force microscopy investigation of the HEMT surface has revealed some correlation between the topography and the leakage current, which is analyzed in detail. The effect of introducing a thin dielectric in the gate is also discussed in the micro and the nanoscale

    Comparing faceted and smoothed tool surface descriptions in sheet metal forming simulation

    Get PDF
    This study deals with different tool surface description methods used in the finite element analysis of sheet metal forming processes. The description of arbitrarily-shaped tool surfaces using the traditional linear finite elements is compared with two distinct smooth surface description approaches: (i) Bézier patches obtained from the ComputerAided Design model and (ii) smoothing the finite element mesh using Nagata patches. The contact search algorithm is presented for each approach, exploiting its special features in order to ensure an accurate and efficient contact detection. The influence of the tool modelling accuracy on the numerical results is analysed using two sheet forming examples, the unconstrained cylindrical bending and the reverse deep drawing of a cylindrical cup. Smoothing the contact surfaces with Nagata patches allows creating more accurate tool models, both in terms of shape and normal vectors, when compared with the conventional linear finite element mesh. The computational efficiency is evaluated in this study through the total number of increments and the required CPU time. The mesh refinement in the faceted description approach is not effective in terms of computational efficiency due to large discontinuities in the normal vector field across facets, even when adopting fine meshes.The authors gratefully acknowledge the financial support of the Portuguese Foundation for Science and Technology (FCT) via the projects PTDC/EME-TME/118420/2010 and PEst-C/EME/ UI0285/2013 and by FEDER funds through the program COMPETE – Programa Operacional Factores de Competitividade, under the project CENTRO-07-0224-FEDER-002001 (MT4MOBI). The first author is also grateful to the FCT for the PhD grant SFRH/BD/69140/2010.info:eu-repo/semantics/publishedVersio

    Multidetector CT imaging of mechanical prosthetic heart valves: quantification of artifacts with a pulsatile in-vitro model

    Get PDF
    Item does not contain fulltextOBJECTIVES: Multidetector computed tomography (MDCT) can detect the cause of prosthetic heart valve (PHV) dysfunction but is hampered by valve-induced artifacts. We quantified artifacts of four PHV using a pulsatile in-vitro model and assessed the relation to leaflet motion and valve design. METHODS: A Medtronic Hall tilting disc (MH), and Carbomedics (CM), St Jude (SJM), and ON-X bileaflet valves underwent CT in an in-vitro model using retrospective gating with a 64 detector CT system in stationary and pulsatile conditions. Artifacts and radiopaque component volumes were quantified with thresholds based on surrounding structures and valvular components. RESULTS: Hypodense artifacts volumes (mm(3)) were 1,029 +/- 147, 535 +/- 53, 371 +/- 16, and 366 +/- 18 for the SJM, MH, CM and ON-X valves (p < 0.001 except for the latter two valves p = 0.43). Hyperdense artifact volumes were 3,546 +/- 141, 2,387 +/- 103, 2,003 +/- 102, and 3,033 +/- 31 for the SJM, MH, CM and ON-X valve, respectively (all differences p < 0.001). Leaflet motion affected hypodense (F = 41.5, p < 0.001) and hyperdense artifacts (F = 53.7, p < 0.001). Closed and moving leaflets were associated with the least and the most artifacts respectively (p < 0.001, both artifact types). CONCLUSION: Both valve design and leaflet motion affect PHV-induced artifacts. Best imaging results may be expected for the CM valve during phases in which the leaflets are closed

    Prosthetic heart valve assessment with multidetector-row CT: imaging characteristics of 91 valves in 83 patients

    Get PDF
    Multidetector CT (MDCT) has shown potential for prosthetic heart valve (PHV) assessment. We assessed the image quality of different PHV types to determine which valves are suitable for MDCT evaluation. All ECG-gated CTs performed in our institutions since 2003 were reviewed for the presence of PHVs. After reconstruction in 3 specific PHV planes, image quality of the supravalvular, perivalvular, subvalvular and valvular regions was scored on a four-point scale (1 = non-diagnostic, 2 = moderate, 3 = good and 4 = excellent) by two independent observers. Eighty-four CT examinations (66 cardiac, 18 limited-dose aortic protocols) of 83 patients with a total of 91 PHVs in the aortic (n = 71), mitral (n = 17), pulmonary (n = 1) and tricuspid (n = 2) position were included. CT was performed on a 16-slice (n = 4), 64-slice (n = 28) or 256-slice (n = 52) MDCT system. Median image quality scores for the supra-, peri- and subvalvular regions and valvular detail were (3.5, 3.3, 3.5 and 3.5, respectively) for bileaflet PHV; (3.0, 3.0, 3.5 and 3.0, respectively) for Medtronic Hall PHV; (1.0, 1.0, 1.0 and 1.0, respectively) for Björk-Shiley and Sorin monoleaflet PHV and (3.5, 3.5, 4.0 and 2.0 respectively) for biological PHV. Currently implanted PHVs have good image quality on MDCT and are suitable for MDCT evaluatio
    • …
    corecore