99 research outputs found

    Polycyclic Aromatic Hydrocarbon-degrading Bacteria from Aviation Fuel Spill Site at Ibeno, Nigeria

    Get PDF
    Polycyclic aromatic hydrocarbon (PAH)–degrading bacteria were isolated from aviation fuel contaminated soil at Inua Eyet Ikot in Ibeno, Nigeria. PAH-degrading bacteria in the contaminated soil were isolated by enrichment culture technique. Isolates with high PAH degrading potential characterized by their extensive growth on PAH-supplemented minimal salt medium were screened for their naphthalene, phenanthrene and chrysene degradability. The screening medium which contained selected PAHs as the sole source of carbon and energy showed that Micrococcus varians AFS-2, Pseudomonas putida AFS-3 and Alcaligenes faecalis AFS-5 exhibited a concentration–dependent growth in all the PAH–compounds tested. There were visible changes in the color of growth medium suggesting the production of different metabolites. Their acclimation to different PAH substrates was also evident as A. faecalis AFS-5 isolated from chrysene grew well on other less complex aromatic compounds. The isolate exhibited best growth (0.44 OD600) when exposed to 10 ppm of chrysene for 5 days and could utilize up to 90 ppm of chrysene. This isolate and others with strong PAH-degrading potentials are recommended for bioremediation of PAHs in aviation fuel-contaminated sites in the tropics

    Raccomandazioni per l\u2019esecuzione della Curva Standard da Carico Orale di Glucosio (OGTT) per la diagnosi di Diabete Mellito

    Get PDF
    The Oral Glucose Tolerance Test (OGTT) is a fractional method which measures the body's ability to metabolize glucose. Despite its large-scale use, the OGTT is still not appropriately performed in most of the Italian laboratories, as proven by our previous recent survey. In particular, we have provided evidence for the variability for execution of the OGTT in Italian laboratories indicating a poor tendency to standardise the procedures and the methodologies. These findings have been a stimulus to promote an effective Nationwide educational campaign, in order to standardise the procedures for the diagnosis of altered glucose metabolism and diabetes. The present document reports therefore the recommendations concerning the OGTT performed for the classification of diabetes. These recommendations do not apply to the execution of the OGTT during pregnancy for diagnosing gestational diabetes mellitus

    an international multi center serum protein electrophoresis accuracy and m protein isotyping study part i factors impacting limit of quantitation of serum protein electrophoresis

    Get PDF
    AbstractBackgroundSerum protein electrophoresis (SPEP) is used to quantify the serum monoclonal component or M-protein, for diagnosis and monitoring of monoclonal gammopathies. Significant imprecision and inaccuracy pose challenges in reporting small M-proteins. Using therapeutic monoclonal antibody-spiked sera and a pooled beta-migrating M-protein, we aimed to assess SPEP limitations and variability across 16 laboratories in three continents.MethodsSera with normal, hypo- or hypergammaglobulinemia were spiked with daratumumab, Dara (cathodal migrating), or elotuzumab, Elo (central-gamma migrating), with concentrations from 0.125 to 10 g/L (n = 62) along with a beta-migrating sample (n = 9). Provided with total protein (reverse biuret, Siemens), laboratories blindly analyzed samples according to their SPEP and immunofixation (IFE) or immunosubtraction (ISUB) standard operating procedures. Sixteen laboratories reported the perpendicular drop (PD) method of gating the M-protein, while 10 used tangent skimming (TS). A mean percent recovery range of 80%–120% was set as acceptable. The inter-laboratory %CV was calculated.ResultsGamma globulin background, migration pattern and concentration all affect the precision and accuracy of quantifying M-proteins by SPEP. As the background increases, imprecision increases and accuracy decreases leading to overestimation of M-protein quantitation especially evident in hypergamma samples, and more prominent with PD. Cathodal migrating M-proteins were associated with less imprecision and higher accuracy compared to central-gamma migrating M-proteins, which is attributed to the increased gamma background contribution in M-proteins migrating in the middle of the gamma fraction. There is greater imprecision and loss of accuracy at lower M-protein concentrations.ConclusionsThis study suggests that quantifying exceedingly low concentrations of M-proteins, although possible, may not yield adequate accuracy and precision between laboratories

    Prenatal exposures and exposomics of asthma

    Get PDF
    This review examines the causal investigation of preclinical development of childhood asthma using exposomic tools. We examine the current state of knowledge regarding early-life exposure to non-biogenic indoor air pollution and the developmental modulation of the immune system. We examine how metabolomics technologies could aid not only in the biomarker identification of a particular asthma phenotype, but also the mechanisms underlying the immunopathologic process. Within such a framework, we propose alternate components of exposomic investigation of asthma in which, the exposome represents a reiterative investigative process of targeted biomarker identification, validation through computational systems biology and physical sampling of environmental medi

    An Integrated Approach for a Structural and Functional Evaluation of Biosimilars: Implications for Erythropoietin

    Get PDF
    BACKGROUND: Authorization to market a biosimilar product by the appropriate institutions is expected based on biosimilarity with its originator product. The analogy between the originator and its biosimilar(s) is assessed through safety, purity, and potency analyses. OBJECTIVE: In this study, we proposed a useful quality control system for rapid and economic primary screening of potential biosimilar drugs. For this purpose, chemical and functional characterization of the originator rhEPO alfa and two of its biosimilars was discussed. METHODS: Qualitative and quantitative analyses of the originator rhEPO alfa and its biosimilars were performed using reversed-phase high-performance liquid chromatography (RP-HPLC). The identification of proteins and the separation of isoforms were studied using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF–MS) and two-dimensional gel electrophoresis (2D-PAGE), respectively. Furthermore, the biological activity of these drugs was measured both in vitro, evaluating the TF-1 cell proliferation rate, and in vivo, using the innovative experimental animal model of the zebrafish embryos. RESULTS: Chemical analyses showed that the quantitative concentrations of rhEPO alfa were in agreement with the labeled claims by the corresponding manufacturers. The qualitative analyses performed demonstrated that the three drugs were pure and that they had the same amino acid sequence. Chemical differences were found only at the level of isoforms containing N-glycosylation; however, functional in vitro and in vivo studies did not show any significant differences from a biosimilar point of view. CONCLUSION: These rapid and economic structural and functional analyses were effective in the evaluation of the biosimilarity between the originator rhEPO alfa and the biosimilars analyzed. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s40259-015-0136-3) contains supplementary material, which is available to authorized users
    • 

    corecore