404 research outputs found

    Laparoendoscopic single-site and natural orifice transluminal endoscopic surgery in urology: a critical analysis of the literature

    Get PDF
    CONTEXT: Natural orifice transluminal endoscopic surgery (NOTES) and laparoendoscopic single-site surgery (LESS) have been developed to benefit patients by enabling surgeons to perform scarless surgery. OBJECTIVE: To summarize and critically analyze the available evidence on the current status and future perspectives of LESS and NOTES in urology. EVIDENCE ACQUISITION: A comprehensive electronic literature search was conducted in June 2010 using the Medline database to identify all publications relating to NOTES and LESS in urology. EVIDENCE SYNTHESIS: In urology, NOTES has been completed experimentally via transgastric, transvaginal, transcolonic, and transvesical routes. Initial clinical experience has shown that NOTES urologic surgery using currently available instruments is indeed possible. Nevertheless, because of the immaturity of the instrumentation, early cases have demanded high technical virtuosity. LESS can safely and effectively be performed in a variety of urologic settings. As clinical experience increases, expanding indications are expected to be documented and the efficacy of the procedure to improve. So far, the quality of evidence of all available studies remains low, mostly being small case series or case-control studies from selected centers. Thus, the only objective benefit of LESS remains the improved cosmetic outcome. Prospective, randomized studies are largely awaited to determine which LESS procedures will be established and which are unlikely to stand the test of time. Technology advances hold promise to minimize the challenging technical nature of scarless surgery. In this respect, robotics is likely to drive a major paradigm shift in the development of LESS and NOTES. CONCLUSIONS: NOTES is still an investigational approach in urology. LESS has proven to be immediately applicable in the clinical field, being safe and feasible in the hands of experienced laparoscopic surgeons. Development of instrumentation and application of robotic technology are expected to define the actual role of these techniques in minimally invasive urologic surgery

    A new resorbable device for ligation of blood vessels - A pilot study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>During surgery, controlled haemostasis to prevent blood loss is vital for a successful outcome. It can be difficult to ligate vessels located deep in the abdomen. A device that is easy to use and enables secure ligatures could be beneficial. Cable ties made of nylon have been used for ligation but the non-resorbable material caused tissue reactions. The objective of this study was to use a resorbable material to construct a device with a self-locking mechanism and to test its mechanical strength and ligation efficiency.</p> <p>Methods</p> <p>The device was manufactured by injection moulding of polydioxanone, a resorbable polymer used for suture materials. Polydioxanone with inherent viscosities of 1.9 dL/g and 1.3 dL/g were tested. The device consisted of a perforated flexible band which could be pulled through a case with a locking mechanism. After a first version of the device had been tested, some improvements were made. The locking case was downsized, corners were rounded off, the band was made thicker and the mould was redesigned to produce longer devices. Tensile tests were performed with the second version.</p> <p>The first version of the device was used to ligate the ovarian pedicle in a euthanized dog and to test echogenicity of the device with ultrasound. Compression of vessels of the ovarian pedicle was examined by histology. Both versions of the device were tested for haemostasis of and tissue grip on renal arteries in six anaesthetised pigs.</p> <p>Results</p> <p>The tensile strength of the flexible band of the devices with inherent viscosity of 1.9 dL/g was 50.1 ± 5.5 N (range 35.2-62.9 N, <it>n </it>= 11) and the devices with inherent viscosity of 1.3 dL/g had a tensile strength of 39.8 ± 8.1 N (range 18.6-54.2 N, <it>n </it>= 11). Injection moulding of the polymer with lower inherent viscosity resulted in a longer flow distance.</p> <p>Both versions of the device had an effective tissue grip and complete haemostasis of renal arteries was verified. The device attached to the ovarian pedicle could be seen with ultrasound, and vessel compression and occlusion were verified by histology.</p> <p>Conclusions</p> <p>Tests of functionality of the device showed complete haemostasis and good tissue grip. Devices with a band of sufficient length were easily applied and tightened in tissue.</p

    Skills training in minimally invasive surgery in Dutch obstetrics and gynecology residency curriculum

    Get PDF
    The complexity of acquiring minimally invasive surgical (MIS) skills, combined with smaller case volumes for residents have pushed the development of skills training facilities on simulators outside the operating room (OR). Medico-legal and financial constraints have stimulated this development even more. However, the implementation of simulator training into a residency curriculum is shown to be troublesome. MIS skills training is organized in a uniform and easily applicable way in the Dutch obstetrics and gynecology residency curriculum. Every resident is obliged to attend the same basic surgical skills course, named Cobra-alpha course, intentionally during postgraduate year (PGY) 1 or 2. Furthermore, surgical skills are trained, evaluated and expanded on simulators in teaching hospitals. Additional to the Cobra-alpha course, residents may attend advanced training courses and congresses focusing on laparoscopy and hysteroscopy. This organization guarantees a uniform introduction to MIS skills training for every resident. However, preconditions for continuous training and evaluation after this introduction have to be optimized

    Retention of basic laparoscopic skills after a structured training program

    Get PDF
    The purpose of this study was to test the retention of basic laparoscopic skills on a box trainer 1 year after a short training program. For a prior study, eight medical students without prior experience (novices) underwent baseline testing, followed by five weekly training sessions and a final test. During each of seven sessions, they performed five tasks on an inanimate box trainer. Scores were calculated by adding up the time to completion of the task with penalty points, consequently rewarding speed and precision. The sum score was the sum of the five scores. One year later, seven of them underwent retention testing for the current study. The final test results were compared with retention test results as a measure of durability of acquired skills. Novices’ scores did not worsen significantly for four out of five tasks (i.e., placing a pipe cleaner p = 0.46, placing beads p = 0.24, cutting a circle p = 0.31, and knot tying p = 0.13). However, deterioration was observed in the performance on stretching a rubber band (p < 0.05), as well as in the sum score (p < 0.05). Nevertheless, all retention scores remained better than the baseline results. In conclusion, basic laparoscopic skills acquired during a short training program merely sustain over time. However, ongoing practice is advisable, especially to preserve tissue-handling skills, since these may be the first to deteriorate

    Salvage radiotherapy for patients with PSA relapse after radical prostatectomy: a single institution experience

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To assess the efficacy of salvage radiotherapy (RT) for persistent or rising PSA after radical prostatectomy and to determine prognostic factors identifying patients who may benefit from salvage RT.</p> <p>Methods</p> <p>Between 1990 and 2003, 59 patients underwent RT for PSA recurrence after radical prostatectomy. Patients received a median of 66 Gy to the prostate bed with 3D or 2D RT. The main end point was biochemical failure after salvage RT, defined as an increase of the serum PSA value >0.2 ng/ml confirmed by a second elevation.</p> <p>Results</p> <p>Median follow-up was 38 months. The 3-year and 5-year bDFS rates were 56.1% and 41.2% respectively. According to multivariate analysis, only preRT PSA ≥1 ng/ml was associated with biochemical relapse.</p> <p>Conclusion</p> <p>When delivered early, RT is an effective treatment after radical prostatectomy. Only preRT PSA ≥1 ng/ml predicted relapse.</p

    Study of Bc+B_c^+ decays to the K+Kπ+K^+K^-\pi^+ final state and evidence for the decay Bc+χc0π+B_c^+\to\chi_{c0}\pi^+

    Get PDF
    A study of Bc+K+Kπ+B_c^+\to K^+K^-\pi^+ decays is performed for the first time using data corresponding to an integrated luminosity of 3.0 fb1\mathrm{fb}^{-1} collected by the LHCb experiment in pppp collisions at centre-of-mass energies of 77 and 88 TeV. Evidence for the decay Bc+χc0(K+K)π+B_c^+\to\chi_{c0}(\to K^+K^-)\pi^+ is reported with a significance of 4.0 standard deviations, resulting in the measurement of σ(Bc+)σ(B+)×B(Bc+χc0π+)\frac{\sigma(B_c^+)}{\sigma(B^+)}\times\mathcal{B}(B_c^+\to\chi_{c0}\pi^+) to be (9.83.0+3.4(stat)±0.8(syst))×106(9.8^{+3.4}_{-3.0}(\mathrm{stat})\pm 0.8(\mathrm{syst}))\times 10^{-6}. Here B\mathcal{B} denotes a branching fraction while σ(Bc+)\sigma(B_c^+) and σ(B+)\sigma(B^+) are the production cross-sections for Bc+B_c^+ and B+B^+ mesons. An indication of bˉc\bar b c weak annihilation is found for the region m(Kπ+)<1.834GeV ⁣/c2m(K^-\pi^+)<1.834\mathrm{\,Ge\kern -0.1em V\!/}c^2, with a significance of 2.4 standard deviations.Comment: All figures and tables, along with any supplementary material and additional information, are available at https://lhcbproject.web.cern.ch/lhcbproject/Publications/LHCbProjectPublic/LHCb-PAPER-2016-022.html, link to supplemental material inserted in the reference

    Measurement of the B0s →J/ψη lifetime

    Get PDF
    Using a data set corresponding to an integrated luminosity of 3 fb−1, collected by the LHCb experiment in pp collisions at centre-of-mass energies of 7 and 8 TeV, the effective lifetime in the Bs0→J/ψη decay mode, τeff, is measured to be τeff=1.479±0.034 (stat)±0.011 (syst) ps. Assuming CP conservation, τeff corresponds to the lifetime of the light Bs0 mass eigenstate. This is the first measurement of the effective lifetime in this decay mode
    corecore