1,440 research outputs found

    Does cemented or cementless single-stage exchange arthroplasty of chronic periprosthetic hip infections provide similar infection rates to a two-stage? A systematic review

    Get PDF
    BACKGROUND: The best surgical modality for treating chronic periprosthetic hip infections remains controversial, with a lack of randomised controlled studies. The aim of this systematic review is to compare the infection recurrence rate after a single-stage versus a two-stage exchange arthroplasty, and the rate of cemented versus cementless single-stage exchange arthroplasty for chronic periprosthetic hip infections. METHODS: We searched for eligible studies published up to December 2015. Full text or abstract in English were reviewed. We included studies reporting the infection recurrence rate as the outcome of interest following single- or two-stage exchange arthroplasty, or both, with a minimum follow-up of 12 months. Two reviewers independently abstracted data and appraised quality assessment. RESULTS: After study selection, 90 observational studies were included. The majority of studies were focused on a two-stage hip exchange arthroplasty (65 %), 18 % on a single-stage exchange, and only a 17 % were comparative studies. There was no statistically significant difference between a single-stage versus a two-stage exchange in terms of recurrence of infection in controlled studies (pooled odds ratio of 1.37 [95 % CI = 0.68-2.74, I(2) = 45.5 %]). Similarly, the recurrence infection rate in cementless versus cemented single-stage hip exchanges failed to demonstrate a significant difference, due to the substantial heterogeneity among the studies. CONCLUSION: Despite the methodological limitations and the heterogeneity between single cohorts studies, if we considered only the available controlled studies no superiority was demonstrated between a single- and two-stage exchange at a minimum of 12 months follow-up. The overalapping of confidence intervals related to single-stage cementless and cemented hip exchanges, showed no superiority of either technique

    Does an antibiotic-loaded hydrogel coating reduce early post-surgical infection after joint arthroplasty?

    Get PDF
    Background: Infection remains among the main reasons for joint prosthesis failure. Preclinical reports have suggested that antibacterial coatings of implants may prevent bacterial adhesion and biofilm formation. This study presents the results of the first clinical trial on an antibiotic-loaded fast-resorbable hydrogel coating (Defensive Antibacterial Coating, DAC®) in patients undergoing hip or knee prosthesis. Methods: In this multicenter, randomized prospective study, a total of 380 patients, scheduled to undergo primary (n=270) or revision (n=110) total hip (N=298) or knee (N=82) joint replacement with a cementless or a hybrid implant, were randomly assigned, in six European orthopedic centers, to receive an implant either with the antibiotic-loaded DAC coating (treatment group) or without coating (control group). Pre- and postoperative assessment of clinical scores, wound healing, laboratory tests, and x-ray exams were performed at fixed time intervals. Results: Overall, 373 patients were available at a mean follow-up of 14.5 ± 5.5 months (range 6 to 24). On average, wound healing, laboratory and radiographic findings showed no significant difference between the two groups. Eleven early surgical site infections were observed in the control group and only one in the treatment group (6% vs. 0.6%; p=0.003). No local or systemic side effects related to the DAC hydrogel coating were observed, and no detectable interference with implant osteointegration was noted. Conclusions: The use of a fast-resorbable, antibiotic-loaded hydrogel implant coating can reduce the rate of early surgical site infections, without any detectable adverse events or side effects after hip or knee joint replacement with a cementless or hybrid implant

    Pumped double quantum dot with spin-orbit coupling

    Get PDF
    We study driven by an external electric field quantum orbital and spin dynamics of electron in a one-dimensional double quantum dot with spin-orbit coupling. Two types of external perturbation are considered: a periodic field at the Zeeman frequency and a single half-period pulse. Spin-orbit coupling leads to a nontrivial evolution in the spin and orbital channels and to a strongly spin- dependent probability density distribution. Both the interdot tunneling and the driven motion contribute into the spin evolution. These results can be important for the design of the spin manipulation schemes in semiconductor nanostructures

    Algorithm for identifying and separating beats from arterial pulse records

    Get PDF
    BACKGROUND: This project was designed as an epidemiological aid-selecting tool for a small country health center with the general objective of screening out possible coronary patients. Peripheral artery function can be non-invasively evaluated by impedance plethysmography. Changes in these vessels appear as good predictors of future coronary behavior. Impedance plethysmography detects volume variations after simple occlusive maneuvers that may show indicative modifications in arterial/venous responses. Averaging of a series of pulses is needed and this, in turn, requires proper determination of the beginning and end of each beat. Thus, the objective here is to describe an algorithm to identify and separate out beats from a plethysmographic record. A secondary objective was to compare the output given by human operators against the algorithm. METHODS: The identification algorithm detected the beat's onset and end on the basis of the maximum rising phase, the choice of possible ventricular systolic starting points considering cardiac frequency, and the adjustment of some tolerance values to optimize the behavior. Out of 800 patients in the study, 40 occlusive records (supradiastolic- subsystolic) were randomly selected without any preliminary diagnosis. Radial impedance plethysmographic pulse and standard ECG were recorded digitizing and storing the data. Cardiac frequency was estimated with the Power Density Function and, thereafter, the signal was derived twice, followed by binarization of the first derivative and rectification of the second derivative. The product of the two latter results led to a weighing signal from which the cycles' onsets and ends were established. Weighed and frequency filters are needed along with the pre-establishment of their respective tolerances. Out of the 40 records, 30 seconds strands were randomly chosen to be analyzed by the algorithm and by two operators. Sensitivity and accuracy were calculated by means of the true/false and positive/negative criteria. Synchronization ability was measured through the coefficient of variation and the median value of correlation for each patient. These parameters were assessed by means of Friedman's ANOVA and Kendall Concordance test. RESULTS: Sensitivity was 97% and 91% for the two operators, respectively, while accuracy was cero for both of them. The synchronism variability analysis was significant (p < 0.01) for the two statistics, showing that the algorithm produced the best result. CONCLUSION: The proposed algorithm showed good performance as expressed by its high sensitivity. The correlation analysis demonstrated that, from the synchronism point of view, the algorithm performed the best detection. Patients with marked arrhythmic processes are not good candidates for this kind of analysis. At most, they would be singled out by the algorithm and, thereafter, to be checked by an operator
    corecore