1,868 research outputs found
Composite-pulse magnetometry with a solid-state quantum sensor
The sensitivity of quantum magnetometers is challenged by control errors and,
especially in the solid-state, by their short coherence times. Refocusing
techniques can overcome these limitations and improve the sensitivity to
periodic fields, but they come at the cost of reduced bandwidth and cannot be
applied to sense static (DC) or aperiodic fields. Here we experimentally
demonstrate that continuous driving of the sensor spin by a composite pulse
known as rotary-echo (RE) yields a flexible magnetometry scheme, mitigating
both driving power imperfections and decoherence. A suitable choice of RE
parameters compensates for different scenarios of noise strength and origin.
The method can be applied to nanoscale sensing in variable environments or to
realize noise spectroscopy. In a room-temperature implementation based on a
single electronic spin in diamond, composite-pulse magnetometry provides a
tunable trade-off between sensitivities in the microT/sqrt(Hz) range,
comparable to those obtained with Ramsey spectroscopy, and coherence times
approaching T1
Effect of antiandrogen flutamide on measures of hepatic regeneration in rats
Male rat liver undergoes a process of demasculinization during hepatic regeneration following partial hepatectomy. The possibility that antiandrogens might potentiate this demasculinization process and in so doing augment the hepatic regenerative response was investigated. Adult male Wistar rats were treated with the antiandrogen flutamide (2 mg/rat/day or 5 mg/rat/day subcutaneously) or vehicle for three days prior to and daily after a 70% partial hepatectomy. At various times after hepatectomy, the liver remnants were removed and weighed. Rates of DNA and polyamine synthesis were assessed by measuring thymidine kinase and ornithine decarboxylase activities, respectively. Hepatic estrogen receptor status and the activity of alcohol dehydrogenase, an androgen-sensitive protein, were measured. Prior to surgery, the administration of 5 mg/day flutamide reduced the hepatic cytosolic androgen receptor activity by 98% and hepatic cytosolic estrogen receptor content by 92% compared to that present in vehicle-treated controls. After hepatectomy, however, all differences in sex hormone receptor activity between the treatment groups were abolished. The rate of liver growth after partial hepatectomy in the three groups was identical. Moreover, hepatectomy-induced increases in ornithine decarboxylase activity and thymidine kinase activity were comparable. These data demonstrate that, although flutamide administration initially alters the sex hormone receptor status of the liver, these affects have no effect on the hepatic regenerative response following a partial hepatectomy. © 1989 Plenum Publishing Corporation
Quantum control of proximal spins using nanoscale magnetic resonance imaging
Quantum control of individual spins in condensed matter systems is an
emerging field with wide-ranging applications in spintronics, quantum
computation, and sensitive magnetometry. Recent experiments have demonstrated
the ability to address and manipulate single electron spins through either
optical or electrical techniques. However, it is a challenge to extend
individual spin control to nanoscale multi-electron systems, as individual
spins are often irresolvable with existing methods. Here we demonstrate that
coherent individual spin control can be achieved with few-nm resolution for
proximal electron spins by performing single-spin magnetic resonance imaging
(MRI), which is realized via a scanning magnetic field gradient that is both
strong enough to achieve nanometric spatial resolution and sufficiently stable
for coherent spin manipulations. We apply this scanning field-gradient MRI
technique to electronic spins in nitrogen-vacancy (NV) centers in diamond and
achieve nanometric resolution in imaging, characterization, and manipulation of
individual spins. For NV centers, our results in individual spin control
demonstrate an improvement of nearly two orders of magnitude in spatial
resolution compared to conventional optical diffraction-limited techniques.
This scanning-field-gradient microscope enables a wide range of applications
including materials characterization, spin entanglement, and nanoscale
magnetometry.Comment: 7 pages, 4 figure
Sensing remote nuclear spins
Sensing single nuclear spins is a central challenge in magnetic resonance
based imaging techniques. Although different methods and especially diamond
defect based sensing and imaging techniques in principle have shown sufficient
sensitivity, signals from single nuclear spins are usually too weak to be
distinguished from background noise. Here, we present the detection and
identification of remote single C-13 nuclear spins embedded in nuclear spin
baths surrounding a single electron spins of a nitrogen-vacancy centre in
diamond. With dynamical decoupling control of the centre electron spin, the
weak magnetic field ~10 nT from a single nuclear spin located ~3 nm from the
centre with hyperfine coupling as weak as ~500 Hz is amplified and detected.
The quantum nature of the coupling is confirmed and precise position and the
vector components of the nuclear field are determined. Given the distance over
which nuclear magnetic fields can be detected the technique marks a firm step
towards imaging, detecting and controlling nuclear spin species external to the
diamond sensor
A Novel Unsupervised Method to Identify Genes Important in the Anti-viral Response: Application to Interferon/Ribavirin in Hepatitis C Patients
Background: Treating hepatitis C with interferon/ribavirin results in a varied response in terms of decrease in viral titer and ultimate outcome. Marked responders have a sharp decline in viral titer within a few days of treatment initiation, whereas in other patients there is no effect on the virus (poor responders). Previous studies have shown that combination therapy modifies expression of hundreds of genes in vitro and in vivo. However, identifying which, if any, of these genes have a role in viral clearance remains challenging. Aims: The goal of this paper is to link viral levels with gene expression and thereby identify genes that may be responsible for early decrease in viral titer. Methods: Microarrays were performed on RNA isolated from PBMC of patients undergoing interferon/ribavirin therapy. Samples were collected at pre-treatment (day 0), and 1, 2, 7, 14 and 28 days after initiating treatment. A novel method was applied to identify genes that are linked to a decrease in viral titer during interferon/ribavirin treatment. The method uses the relationship between inter-patient gene expression based proximities and inter-patient viral titer based proximities to define the association between microarray gene expression measurements of each gene and viral-titer measurements. Results: We detected 36 unique genes whose expressions provide a clustering of patients that resembles viral titer based clustering of patients. These genes include IRF7, MX1, OASL and OAS2, viperin and many ISG's of unknown function. Conclusion: The genes identified by this method appear to play a major role in the reduction of hepatitis C virus during the early phase of treatment. The method has broad utility and can be used to analyze response to any group of factors influencing biological outcome such as antiviral drugs or anti-cancer agents where microarray data are available. © 2007 Brodsky et al
A robust, scanning quantum system for nanoscale sensing and imaging
Controllable atomic-scale quantum systems hold great potential as sensitive
tools for nanoscale imaging and metrology. Possible applications range from
nanoscale electric and magnetic field sensing to single photon microscopy,
quantum information processing, and bioimaging. At the heart of such schemes is
the ability to scan and accurately position a robust sensor within a few
nanometers of a sample of interest, while preserving the sensor's quantum
coherence and readout fidelity. These combined requirements remain a challenge
for all existing approaches that rely on direct grafting of individual solid
state quantum systems or single molecules onto scanning-probe tips. Here, we
demonstrate the fabrication and room temperature operation of a robust and
isolated atomic-scale quantum sensor for scanning probe microscopy.
Specifically, we employ a high-purity, single-crystalline diamond nanopillar
probe containing a single Nitrogen-Vacancy (NV) color center. We illustrate the
versatility and performance of our scanning NV sensor by conducting
quantitative nanoscale magnetic field imaging and near-field single-photon
fluorescence quenching microscopy. In both cases, we obtain imaging resolution
in the range of 20 nm and sensitivity unprecedented in scanning quantum probe
microscopy
Fitness Ranking of Individual Mutants Drives Patterns of Epistatic Interactions in HIV-1
This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited
Publishing and sharing multi-dimensional image data with OMERO
Imaging data are used in the life and biomedical sciences to measure the molecular and structural composition and dynamics of cells, tissues, and organisms. Datasets range in size from megabytes to terabytes and usually contain a combination of binary pixel data and metadata that describe the acquisition process and any derived results. The OMERO image data management platform allows users to securely share image datasets according to specific permissions levels: data can be held privately, shared with a set of colleagues, or made available via a public URL. Users control access by assigning data to specific Groups with defined membership and access rights. OMERO’s Permission system supports simple data sharing in a lab, collaborative data analysis, and even teaching environments. OMERO software is open source and released by the OME Consortium at www.openmicroscopy.org
Do red deer stags (Cervus elaphus) use roar fundamental frequency (F0) to assess rivals?
It is well established that in humans, male voices are disproportionately lower pitched than female voices, and recent studies suggest that this dimorphism in fundamental frequency (F0) results from both intrasexual (male competition) and intersexual (female mate choice) selection for lower pitched voices in men. However, comparative investigations indicate that sexual dimorphism in F0 is not universal in terrestrial mammals. In the highly polygynous and sexually dimorphic Scottish red deer Cervus elaphus scoticus, more successful males give sexually-selected calls (roars) with higher minimum F0s, suggesting that high, rather than low F0s advertise quality in this subspecies. While playback experiments demonstrated that oestrous females prefer higher pitched roars, the potential role of roar F0 in male competition remains untested. Here we examined the response of rutting red deer stags to playbacks of re-synthesized male roars with different median F0s. Our results show that stags’ responses (latencies and durations of attention, vocal and approach responses) were not affected by the F0 of the roar. This suggests that intrasexual selection is unlikely to strongly influence the evolution of roar F0 in Scottish red deer stags, and illustrates how the F0 of terrestrial mammal vocal sexual signals may be subject to different selection pressures across species. Further investigations on species characterized by different F0 profiles are needed to provide a comparative background for evolutionary interpretations of sex differences in mammalian vocalizations
Pleosporales
One hundred and five generic types of Pleosporales are described and illustrated. A brief introduction and detailed history with short notes on morphology, molecular phylogeny as well as a general conclusion of each genus are provided. For those genera where the type or a representative specimen is unavailable, a brief note is given. Altogether 174 genera of Pleosporales are treated. Phaeotrichaceae as well as Kriegeriella, Zeuctomorpha and Muroia are excluded from Pleosporales. Based on the multigene phylogenetic analysis, the suborder Massarineae is emended to accommodate five families, viz. Lentitheciaceae, Massarinaceae, Montagnulaceae, Morosphaeriaceae and Trematosphaeriaceae
- …
