151 research outputs found

    Spitzer Observations of the North Ecliptic Pole

    Get PDF
    We present a photometric catalog for Spitzer Space Telescope warm mission observations of the North Ecliptic Pole (NEP; centered at R.A.=18h00m00s\rm R.A.=18^h00^m00^s, Decl.=66d33m38s.552\rm Decl.=66^d33^m38^s.552). The observations are conducted with IRAC in 3.6 μ\mum and 4.5 μ\mum bands over an area of 7.04 deg2^2 reaching 1σ\sigma depths of 1.29 μ\muJy and 0.79 μ\muJy in the 3.6 μ\mum and 4.5 μ\mum bands respectively. The photometric catalog contains 380,858 sources with 3.6 μ\mum and 4.5 μ\mum band photometry over the full-depth NEP mosaic. Point source completeness simulations show that the catalog is 80% complete down to 19.7 AB. The accompanying catalog can be utilized in constraining the physical properties of extra-galactic objects, studying the AGN population, measuring the infrared colors of stellar objects, and studying the extra-galactic infrared background light.Comment: 10 pages, 11 figures and 3 tables. Accepted to the ApJ

    Validation of the Munich Actimetry Sleep Detection Algorithm for estimating sleep-wake patterns from activity recordings

    Get PDF
    © 2021 The Authors. Journal of Sleep Research published by John Wiley & Sons Ltd on behalf of European Sleep Research Society. This is an open access article under the terms of the Creative Commons Attribution‐NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.Periods of sleep and wakefulness can be estimated from wrist-locomotor activity recordings via algorithms that identify periods of relative activity and inactivity. Here, we evaluated the performance of our Munich Actimetry Sleep Detection Algorithm. The Munich Actimetry Sleep Detection Algorithm uses a moving 24-h threshold and correlation procedure estimating relatively consolidated periods of sleep and wake. The Munich Actimetry Sleep Detection Algorithm was validated against sleep logs and polysomnography. Sleep-log validation was performed on two field samples collected over 54 and 34 days (median) in 34 adolescents and 28 young adults. Polysomnographic validation was performed on a clinical sample of 23 individuals undergoing one night of polysomnography. Epoch-by-epoch analyses were conducted and comparisons of sleep measures carried out via Bland-Altman plots and correlations. Compared with sleep logs, the Munich Actimetry Sleep Detection Algorithm classified sleep with a median sensitivity of 80% (interquartile range [IQR] = 75%-86%) and specificity of 91% (87%-92%). Mean onset and offset times were highly correlated (r = .86-.91). Compared with polysomnography, the Munich Actimetry Sleep Detection Algorithm reached a median sensitivity of 92% (85%-100%) but low specificity of 33% (10%-98%), owing to the low frequency of wake episodes in the night-time polysomnographic recordings. The Munich Actimetry Sleep Detection Algorithm overestimated sleep onset (~21 min) and underestimated wake after sleep onset (~26 min), while not performing systematically differently from polysomnography in other sleep parameters. These results demonstrate the validity of the Munich Actimetry Sleep Detection Algorithm in faithfully estimating sleep-wake patterns in field studies. With its good performance across daytime and night-time, it enables analyses of sleep-wake patterns in long recordings performed to assess circadian and sleep regularity and is therefore an excellent objective alternative to sleep logs in field settings.ASL received a stipend from the Max‐Weber‐Programm (Studienstiftung), AMB received funding from the Graduate School of Systemic Neurosciences Munich, CR received funding from the Fundação para a Ciência e Tecnologia (FCT) PhD research grants (PDE/BDE/114584/2016), LKP received a fellowship from the Coordenação de Aperfeiçoamento Pessoal de Nível Superior (CAPES, Finance Code 001), and NG received research funding from the FoeFoLe program at LMU (registration No. 37/2013).info:eu-repo/semantics/publishedVersio

    Carotid Ultrasound Boundary Study (CUBS): An Open Multicenter Analysis of Computerized Intima–Media Thickness Measurement Systems and Their Clinical Impact

    Get PDF
    Common carotid intima–media thickness (CIMT) is a commonly used marker for atherosclerosis and is often computed in carotid ultrasound images. An analysis of different computerized techniques for CIMT measurement and their clinical impacts on the same patient data set is lacking. Here we compared and assessed five computerized CIMT algorithms against three expert analysts’ manual measurements on a data set of 1088 patients from two centers. Inter- and intra-observer variability was assessed, and the computerized CIMT values were compared with those manually obtained. The CIMT measurements were used to assess the correlation with clinical parameters, cardiovascular event prediction through a generalized linear model and the Kaplan–Meier hazard ratio. CIMT measurements obtained with a skilled analyst's segmentation and the computerized segmentation were comparable in statistical analyses, suggesting they can be used interchangeably for CIMT quantification and clinical outcome investigation. To facilitate future studies, the entire data set used is made publicly available for the community at http://dx.doi.org/10.17632/fpv535fss7.1

    Paediatric CT scan usage and referrals of children to computed tomography in Germany-a cross-sectional survey of medical practice and awareness of radiation related health risks among physicians

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Computed tomography (CT) is a major source of ionizing radiation exposure in medical diagnostic. Compared to adults, children are supposed to be more susceptible to health risks related to radiation. The purpose of a cross-sectional survey among office-based physicians in Germany was the assessment of medical practice in paediatric CT referrals and to investigate physicians' knowledge of radiation doses and potential health risks of radiation exposure from CT in children.</p> <p>Methods</p> <p>A standardized questionnaire was distributed to all paediatricians and surgeons in two defined study areas. Furthermore, the study population included a random sample of general practitioners in the two areas. The questionnaire covered the frequency of referrals for paediatric CT examinations, the medical diagnoses leading to paediatric CT referrals, physicians' knowledge of radiation doses and potential health risks of radiation exposure from CT in children.</p> <p>Results</p> <p>A total of 295 (36.4%) physicians responded. 59% of the doctors had not referred a child to CT in the past year, and approximately 30% referred only 1-5 children annually. The most frequent indications for a CT examination in children were trauma or a suspected cancer. 42% of the referrals were related to minor diagnoses or unspecific symptoms. The participants underestimated the radiation exposure due to CT and they overestimated the radiation exposure due to conventional X-ray examinations.</p> <p>Conclusions</p> <p>In Germany, the frequency of referrals of children to computed tomography is moderate. The knowledge on the risks from radiation exposure among office-based physicians in our sample varied, but there was a tendency to underestimate potential CT risks. Advanced radiological training might lead to considerable amendments in terms of knowledge and practice of CT referral.</p

    Graphene Oxide-Gallic Acid Nanodelivery System for Cancer Therapy

    Get PDF
    Despite the technological advancement in the biomedical science, cancer remains a life-threatening disease. In this study, we designed an anticancer nanodelivery system using graphene oxide (GO) as nanocarrier for an active anticancer agent gallic acid (GA). The successful formation nanocomposite (GOGA) was characterized using XRD, FTIR, HRTEM, Raman, and UV/Vis spectroscopy. The release study shows that the release of GA from the designed anticancer nanocomposite (GOGA) occurs in a sustained manner in phosphate-buffered saline (PBS) solution at pH 7.4. In in vitro biological studies, normal fibroblast (3T3) and liver cancer cells (HepG2) were treated with different concentrations of GO, GOGA, and GA for 72 h. The GOGA nanocomposite showed the inhibitory effect to cancer cell growth without affecting normal cell growth. The results of this research are highly encouraging to go further for in vivo studies

    Biomonitoring of complex occupational exposures to carcinogens: The case of sewage workers in Paris

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Sewage workers provide an essential service in the protection of public and environmental health. However, they are exposed to varied mixtures of chemicals; some are known or suspected to be genotoxics or carcinogens. Thus, trying to relate adverse outcomes to single toxicant is inappropriate. We aim to investigate if sewage workers are at increased carcinogenic risk as evaluated by biomarkers of exposure and early biological effects.</p> <p>Methods/design</p> <p>This cross sectional study will compare exposed sewage workers to non-exposed office workers. Both are voluntaries from Paris municipality, males, aged (20–60) years, non-smokers since at least six months, with no history of chronic or recent illness, and have similar socioeconomic status. After at least 3 days of consecutive work, blood sample and a 24-hour urine will be collected. A caffeine test will be performed, by administering coffee and collecting urines three hours after. Subjects will fill in self-administered questionnaires; one covering the professional and lifestyle habits while the a second one is alimentary. The blood sample will be used to assess DNA adducts in peripheral lymphocytes. The 24-hour urine to assess urinary 8-oxo-7, 8-dihydro-2'-deoxy-Guanosine (8-oxo-dG), and the in vitro genotoxicity tests (comet and micronucleus) using HeLa S3 or HepG2 cells. In parallel, occupational air sampling will be conducted for some Polycyclic Aromatic Hydrocarbons and Volatile Organic Compounds. A weekly sampling chronology at the offices of occupational medicine in Paris city during the regular medical visits will be followed. This protocol has been accepted by the French Est III Ethical Comitee with the number 2007-A00685-48.</p> <p>Discussion</p> <p>Biomarkers of exposure and of early biological effects may help overcome the limitations of environmental exposure assessment in very complex occupational or environmental settings.</p

    Impact of liver cirrhosis, the severity of cirrhosis, and portal hypertension on the outcomes of minimally invasive left lateral sectionectomies for primary liver malignancies

    Get PDF

    Impact of tumor size on the difficulty of laparoscopic left lateral sectionectomies

    Get PDF

    Defining Global Benchmarks for Laparoscopic Liver Resections: An International Multicenter Study

    Get PDF

    Impact of liver cirrhosis, severity of cirrhosis and portal hypertension on the difficulty of laparoscopic and robotic minor liver resections for primary liver malignancies in the anterolateral segments

    Get PDF
    corecore