190 research outputs found

    On the comparison of age determination methods based on dental development radiographic studies in a sample of Italian population

    Get PDF
    OBJECTIVES: This study investigated the degree of reliability, complexity of use and possibility of further refinement of eight radiographic methods for the age determination of subjects in the growth phase, applied on a sample of Italian population. MATERIALS AND METHODS: Each considered method was tested on a sample of 178 digitized panoramic radiographs (97 males and 81 females, aged 5 to 22 years). The obtained data were processed by statistical analysis. RESULTS: The overall Absolute Mean Error (AME) was on average equal to 0.89 years; within this error range fell approximately 61% of the subjects in our sample. The overall average of AME plus 1 standard deviation (SD) was equal to approximately 1.70 years, in the context of which fell about 84.5% of the sample investigated. CONCLUSIONS: The statistical analysis of the data obtained by applying on our sample the considered methods showed, for each of them, the level of reliability in terms of absolute error with the relative SD (i.e., exact match between the age determined by the evaluators and the actual age, in terms of absolute value)

    Autoptic findings of sudden cardiac death (SCD) in patients with arrhythmogenic ventricular cardiomiopathy (AVC) from left ventricle and biventricular involvement

    Get PDF
    Objectives: To evaluate autoptic histopathological findings of arrhythmogenic ventricular cardiomyopathy (AVC) as major cause of sudden cardiac death (SCD) in young adults. Background: According to Heart Rhythm Society (HRS)’s international consensus, histological criteria for AVC diagnosis include a progressive myocardial atrophy of the right ventricle characterized by a transmural fatty or fibrofatty replacement in a segmental or diffuse pattern (residual myocytes <60 % vs 60–75 % by morphometric analysis) explaining the electrical instability with increased risk of SCD. However, there is increasing evidence for atypical patterns of localizations and percentage of fibrofatty replacement suggesting the need to update histopathological features of AVC. Methods: Histology examination of ventricles, atria, and septum was performed on 10 autopsy of SCD due to AVC. Staining with hematoxylin-eosin and PicroSirius Red/Fast Green were performed on the heart samples to identify specific fibrofatty patterns. Results: Our analysis showed that: 1) myocardial replacement by a diffuse segmental fatty or fibro-fatty tissue characterized right and left ventricles as well as atrial walls; 2) the degree of fibrofatty tissue replacement was less than 40 % both in left ventricle (n = 4, 40 %) and biventricular (n = 6, 60 %) localization; 3) perivascular fibrosis, inflammatory infiltrate, areas of hypertrophy and/or areas of coagulative necrosis as signs of hypoxic damage in the first stage. Conclusions: We confirmed prior evidence for fibrofatty replacement both in biventricular and septal localizations. Importantly, we observed a less degree (<40 %) of fibrofatty replacement as compared to current guidelines. This supports the need to further explore the histological patterns of fibrofatty infiltration in a larger study population to improve the histological diagnostic criteria of AVC

    Post-traumatic stress disorder, emotional processing and Inappropriate Implantable Cardioverter-Defibrillator Shocks: clinical consideration by a single case report = Disturbo post-traumatico da stress, profilo cognitivo-emotivo e shocks inappropriati del defibrillatore cardiaco impiantabile: Considerazioni cliniche attraverso un single case report

    Get PDF
    Introduction. Even though an overwhelming amount of evidence supports the clinical efficacy and safety of the implantable cardioverter defibrillator (ICD), inappropriate shocks for atrial arrhythmias with rapid ventricular conduction or for abnormal sensing results in multiple adverse effects Presentation. In this study we present the case of a 59- year-old woman who was admitted to hospital for ICD implantation with a past medical history that was positive for non-ischemic dilated cardiomyopathy, congestive heart failure (NYHA class III), atrial fibrillation, essential hypertension and a recent episode of syncope. Since in the 18 months follow-up the patient suffered many inappropriate shocks, we investigated the association of the presence of a PTSD (Post- Traumatic-Stress-Disorder) prior to implantation and a specific profile of cognitive processing emotions, with the effectiveness of the ICD. Emotional distress states and cognitive thoughts preceding ICD shock inappropriate episode were recorded by structured mobile diary (eMotional-ICDiary). We outlined how the presence of a highly traumatic event which had occurred 6 years previously was related to a recurrence of a combination of moderate distress and cognitive thoughts, associated with episodes of Inappropriate Shock. A psycho-diagnostic examination and the administration of the Emotional Processing Scale (EPS-25) and Emotional Regulation Questionnaire (ERQ) outlined that the patient presented a profile of cognitive processing of emotions characterized by elevated levels of unprocessed emotions, low appraisal and high suppression emotional regulation strategy. Conclusion. The observations gathered in this single case are a good starting point for further research in order to check if the post-traumatic stress disorder and a specific cognitive profile connected to the processing of emotions are associated with the presence of inappropriate ICD shocks. Further larger sample studies are required in this area

    Post-traumatic stress disorder, emotional processing and Inappropriate Implantable Cardioverter-Defibrillator Shocks: clinical consideration by a single case report

    Get PDF
    Introduction. Even though an overwhelming amount of evidence supports the clinical efficacy and safety of the implantable cardioverter defibrillator (ICD), inappropriate shocks for atrial arrhythmias with rapid ventricular conduction or for abnormal sensing results in multiple adverse effects Presentation. In this study we present the case of a 59- year-old woman who was admitted to hospital for ICD implantation with a past medical history that was positive for non-ischemic dilated cardiomyopathy, congestive heart failure (NYHA class III), atrial fibrillation, essential hypertension and a recent episode of syncope. Since in the 18 months follow-up the patient suffered many inappropriate shocks, we investigated the association of the presence of a PTSD (Post- Traumatic-Stress-Disorder) prior to implantation and a specific profile of cognitive processing emotions, with the effectiveness of the ICD. Emotional distress states and cognitive thoughts preceding ICD shock inappropriate episode were recorded by structured mobile diary (eMotional-ICDiary©). We outlined how the presence of a highly traumatic event which had occurred 6 years previously was related to a recurrence of a combination of moderate distress and cognitive thoughts, associated with episodes of Inappropriate Shock. A psycho-diagnostic examination and the administration of the Emotional Processing Scale (EPS-25) and Emotional Regulation Questionnaire (ERQ) outlined that the patient presented a profile of cognitive processing of emotions characterized by elevated levels of unprocessed emotions, low appraisal and high suppression emotional regulation strategy. Conclusion. The observations gathered in this single case are a good starting point for further research in order to check if the post-traumatic stress disorder and a specific cognitive profile connected to the processing of emotions are associated with the presence of inappropriate ICD shocks. Further larger sample studies are required in this area

    Genetic research: the role of citizens, public health and international stakeholders

    Get PDF
    Background: Genetic research has become an indispensable instrument for medical research, and the subjects involved have both divergent and convergent interests. Objective: The possibility of having more detailed genetic information undoubtedly offers benefits for the health of the subject, but could also pose risks and make the subject vulnerable to discrimination. Methods: The scientific community has viewed very favorably the public health utility of family history, in which data from a family whose members suffer from chronic pathologies is collected and filed, in order to develop a sort of “stratification of family risk.” Even though in the last decade the scientific and juridical literature has contributed greatly to the topic of biobanks, the perplexities that continue to surround this theme give the idea that current ethical protocols on research are inadequate. Results: Researchers, citizens, International stakeholders, mass media, Public Health and Governments play a key role in genetic research. It is obvious that the methods used for genetic research do not present intrinsic risks; they are much less dangerous than other activities of diagnosis and research. Before authorizing a research project, it is important to reflect on the responsibility and transparency of the studies to be conducted, and on the impact they may have on the interests of public health. Conclusion: We believe that the highest priority need is to develop a common language on the theme, as is the case in the sphere of clinical experimentation where rules of good clinical practice, albeit at times conflicting, have led to uniform convergences in the scientific world on the points to be actuated
    • …
    corecore