227 research outputs found
Influence of chopped laser light onto the electronic transport through atomic-sized contacts
This article reports on the influence of laser irradiation onto the
electrical conductance of gold nanocontacts established with the mechanically
controllable breakjunction technique (MCB). We concentrate here on the study of
reversible conductance changes which can be as high as 200%. We investigate the
dependence on the initial conductance of the contacts, the wavelength, the
intensity and position of the laser spot with respect to the sample. Under most
conditions an enhancement of the conductance is observed. We discuss several
physical mechanisms which might contribute to the observed effect including
thermal expansion, rectification and photon-assisted transport. We conclude
that thermal expansion is not the dominating one.Comment: 20 pages with 7 figures; conference contribution on the 9th near
field optics conference 2006 in Lausanne, Switzerland; accepted by the
Journal of Microscop
Follow-up of vestibular function in bilateral vestibulopathy
Objective: Bilateral vestibulopathy (BV) leads to a bilateral deficit of the vestibulo-ocular reflex and has various aetiologies. The main goal of this study was to determine the frequency and degree of recovery or worsening of vestibular function over time.Methods: 82 patients (59 males, 23 females; mean age at the time of diagnosis 56.3 (SD 17.6) years) were re-examined 51 (36) months after the first examination. All patients underwent a standardised neuro-ophthalmological and neuro-otological examination. Electronystagmography with bithermal caloric irrigation was analysed by measurement of the mean peak slow phase velocity (SPV) of the induced nystagmus. Patients evaluated the course of their disease in terms of balance, gait unsteadiness and health related quality of life.Results: Statistical analysis of the mean peak SPV of caloric induced nystagmus revealed a non-significant worsening over time (initial mean peak SPV 3.0 (3.5)°/s vs 2.1 (2.8)°/s). With respect to subgroups of aetiology, only patients with BV due to meningitis exhibited an increasing, but non-significant SPV (1.0 (1.4)°/s vs 1.9 (1.6)°/s). Vestibular outcome was independent of age, gender, time course of manifestation and severity of BV. Single analysis of all patients showed that a substantial improvement ⩾5°/s occurred in two patients on both sides (idiopathic n = 1, Sjögren's syndrome n = 1) and in eight patients on one side (idiopathic n = 6, meningitis n = 1, Menière's disease n = 1). In 84% of patients there was impairment of their health related quality of life (42% slight, 24% moderate, 18% severe). Forty-three per cent of patients rated the course of their disease as stable, 28% as worsened and 29% as improved.Conclusions: Our data support the view that more than 80% of patients with BV do not improve. Thus the prognosis of BV is less favourable than assumed
Lines Missing Every Random Point
We prove that there is, in every direction in Euclidean space, a line that
misses every computably random point. We also prove that there exist, in every
direction in Euclidean space, arbitrarily long line segments missing every
double exponential time random point.Comment: Added a section: "Betting in Doubly Exponential Time.
Calibration of TCCON column-averaged CO2: the first aircraft campaign over European TCCON sites
The Total Carbon Column Observing Network (TCCON) is a ground-based network of Fourier Transform Spectrometer (FTS) sites around the globe, where the column abundances of CO2, CH4, N2O, CO and O2 are measured. CO2 is constrained with a precision better than 0.25% (1-σ). To achieve a similarly high accuracy, calibration to World Meteorological Organization (WMO) standards is required. This paper introduces the first aircraft calibration campaign of five European TCCON sites and a mobile FTS instrument. A series of WMO standards in-situ profiles were obtained over European TCCON sites via aircraft and compared with retrievals of CO2 column amounts from the TCCON instruments. The results of the campaign show that the FTS measurements are consistently biased 1.1% ± 0.2% low with respect to WMO standards, in agreement with previous TCCON calibration campaigns. The standard a priori profile for the TCCON FTS retrievals is shown to not add a bias. The same calibration factor is generated using aircraft profiles as a priori and with the TCCON standard a priori. With a calibration to WMO standards, the highly precise TCCON CO2 measurements of total column concentrations provide a suitable database for the calibration and validation of nadir-viewing satellite
Calibration of sealed HCl cells used for TCCON instrumental line shape monitoring
The TCCON (Total Carbon Column Observing
Network) FTIR (Fourier transform infrared) network
provides highly accurate observations of greenhouse gas
column-averaged dry-air mole fractions. As an important
component of TCCON quality assurance, sealed cells filled
with approximately 5 mbar of HCl are used for instrumental
line shape (ILS) monitoring at all TCCON sites. Here,
we introduce a calibration procedure for the HCl cells which
employs a refillable, pressure-monitored reference cell filled
with C_2H_2. Using this method, we identify variations of HCl
purity between the TCCON cells as a non-negligible disturbance.
The new calibration procedure introduced here assigns
effective pressure values to each individual cell to account
for additional broadening of the HCl lines. This approach
will improve the consistency of the network by significantly
reducing possible station-to-station biases due to
inconsistent ILS results from different HCl cells. We demonstrate
that the proposed method is accurate enough to turn the
ILS uncertainty into an error source of secondary importance
from the viewpoint of network consistency
- …