227 research outputs found

    Influence of chopped laser light onto the electronic transport through atomic-sized contacts

    Full text link
    This article reports on the influence of laser irradiation onto the electrical conductance of gold nanocontacts established with the mechanically controllable breakjunction technique (MCB). We concentrate here on the study of reversible conductance changes which can be as high as 200%. We investigate the dependence on the initial conductance of the contacts, the wavelength, the intensity and position of the laser spot with respect to the sample. Under most conditions an enhancement of the conductance is observed. We discuss several physical mechanisms which might contribute to the observed effect including thermal expansion, rectification and photon-assisted transport. We conclude that thermal expansion is not the dominating one.Comment: 20 pages with 7 figures; conference contribution on the 9th near field optics conference 2006 in Lausanne, Switzerland; accepted by the Journal of Microscop

    Follow-up of vestibular function in bilateral vestibulopathy

    Get PDF
    Objective: Bilateral vestibulopathy (BV) leads to a bilateral deficit of the vestibulo-ocular reflex and has various aetiologies. The main goal of this study was to determine the frequency and degree of recovery or worsening of vestibular function over time.Methods: 82 patients (59 males, 23 females; mean age at the time of diagnosis 56.3 (SD 17.6) years) were re-examined 51 (36) months after the first examination. All patients underwent a standardised neuro-ophthalmological and neuro-otological examination. Electronystagmography with bithermal caloric irrigation was analysed by measurement of the mean peak slow phase velocity (SPV) of the induced nystagmus. Patients evaluated the course of their disease in terms of balance, gait unsteadiness and health related quality of life.Results: Statistical analysis of the mean peak SPV of caloric induced nystagmus revealed a non-significant worsening over time (initial mean peak SPV 3.0 (3.5)°/s vs 2.1 (2.8)°/s). With respect to subgroups of aetiology, only patients with BV due to meningitis exhibited an increasing, but non-significant SPV (1.0 (1.4)°/s vs 1.9 (1.6)°/s). Vestibular outcome was independent of age, gender, time course of manifestation and severity of BV. Single analysis of all patients showed that a substantial improvement ⩾5°/s occurred in two patients on both sides (idiopathic n = 1, Sjögren's syndrome n = 1) and in eight patients on one side (idiopathic n = 6, meningitis n = 1, Menière's disease n = 1). In 84% of patients there was impairment of their health related quality of life (42% slight, 24% moderate, 18% severe). Forty-three per cent of patients rated the course of their disease as stable, 28% as worsened and 29% as improved.Conclusions: Our data support the view that more than 80% of patients with BV do not improve. Thus the prognosis of BV is less favourable than assumed

    Lines Missing Every Random Point

    Full text link
    We prove that there is, in every direction in Euclidean space, a line that misses every computably random point. We also prove that there exist, in every direction in Euclidean space, arbitrarily long line segments missing every double exponential time random point.Comment: Added a section: "Betting in Doubly Exponential Time.

    Calibration of TCCON column-averaged CO2: the first aircraft campaign over European TCCON sites

    Get PDF
    The Total Carbon Column Observing Network (TCCON) is a ground-based network of Fourier Transform Spectrometer (FTS) sites around the globe, where the column abundances of CO2, CH4, N2O, CO and O2 are measured. CO2 is constrained with a precision better than 0.25% (1-σ). To achieve a similarly high accuracy, calibration to World Meteorological Organization (WMO) standards is required. This paper introduces the first aircraft calibration campaign of five European TCCON sites and a mobile FTS instrument. A series of WMO standards in-situ profiles were obtained over European TCCON sites via aircraft and compared with retrievals of CO2 column amounts from the TCCON instruments. The results of the campaign show that the FTS measurements are consistently biased 1.1% ± 0.2% low with respect to WMO standards, in agreement with previous TCCON calibration campaigns. The standard a priori profile for the TCCON FTS retrievals is shown to not add a bias. The same calibration factor is generated using aircraft profiles as a priori and with the TCCON standard a priori. With a calibration to WMO standards, the highly precise TCCON CO2 measurements of total column concentrations provide a suitable database for the calibration and validation of nadir-viewing satellite

    Calibration of sealed HCl cells used for TCCON instrumental line shape monitoring

    Get PDF
    The TCCON (Total Carbon Column Observing Network) FTIR (Fourier transform infrared) network provides highly accurate observations of greenhouse gas column-averaged dry-air mole fractions. As an important component of TCCON quality assurance, sealed cells filled with approximately 5 mbar of HCl are used for instrumental line shape (ILS) monitoring at all TCCON sites. Here, we introduce a calibration procedure for the HCl cells which employs a refillable, pressure-monitored reference cell filled with C_2H_2. Using this method, we identify variations of HCl purity between the TCCON cells as a non-negligible disturbance. The new calibration procedure introduced here assigns effective pressure values to each individual cell to account for additional broadening of the HCl lines. This approach will improve the consistency of the network by significantly reducing possible station-to-station biases due to inconsistent ILS results from different HCl cells. We demonstrate that the proposed method is accurate enough to turn the ILS uncertainty into an error source of secondary importance from the viewpoint of network consistency
    corecore