156 research outputs found

    Design and Development of the Observation and Analysis of Smectic Islands in Space Experiment

    Get PDF
    The primary objective of Observation and Analysis of Smectic Islands in Space (OASIS) experiment is to exploit the unique characteristics of freely suspended liquid crystals in a microgravity environment to advance the understanding of fluid state physic

    Produção de haplóides androgenéticos em milho.

    Get PDF
    A cultura do milho; O milho híbrido; Obtenção de linhagens haplóides de milho; Sistema gametófito indeterminado (ig1); Obtenção de linhagens duplo haplóides.bitstream/CNPMS-2010/22388/1/Doc-81.pd

    TEG® and RapidTEG® are unreliable for detecting warfarin-coagulopathy: a prospective cohort study

    Get PDF
    BACKGROUND: Thromboelastography® (TEG) utilizes kaolin, an intrinsic pathway activator, to assess clotting function. Recent published studies suggest that TEG results are commonly normal in patients receiving warfarin, despite an increased International Normalized Ratio (INR). Because RapidTEG™ includes tissue factor, an extrinsic pathway activator, as well as kaolin, we hypothesized that RapidTEG would be more sensitive in detecting a warfarin-effect. METHODS: Included in this prospective study were 22 consecutive patients undergoing elective cardioversion and receiving warfarin. Prior to cardioversion, blood was collected to assess INR, Prothrombin Time, TEG, and RapidTEG. RESULTS: INR Results: 2.8 ± 0.5 (1.6 to 4.2). Prothrombin Time Results: 19.1 ± 2.2 (13.9. to 24.3). TEG Results (Reference Range): R-Time: 8.3 ± 2.7 (2–8); K-Time: 2.1 ± 1.4 (1–3); Angle: 62.5 ± 10.3 (55–78); MA: 63.2 ± 10.3 (51–69); G: 9.4 ± 3.5 (4.6-10.9); R-Time within normal range: 10 (45.5%) with INR 2.9 ± 0.3; Correlation coefficients for INR and each of the 5 TEG variables were insignificant (P > 0.05). RapidTEG Results (Reference Range): ACT: 132 ± 58 (86–118); K-Time: 1.2 ± 0.5 (1–2); Angle: 75.4 ± 5.2 (64–80); MA: 63.4 ± 5.1 (52–71); G: 8.9 ± 2.0 (5.0-11.6); ACT within normal range: 9 (40.9%) with INR 2.7 ± 0.5; Correlation coefficients for INR and each of the 5 RapidTEG variables were insignificant (P > 0.05). CONCLUSIONS: TEG, using kaolin activation, and RapidTEG, with kaolin and tissue factor activation, were normal in a substantial percent of warfarin patients, despite an increased INR. The false-negative rate for detecting warfarin coagulopathy with either test is unacceptable. The lack of correlation between INR and all TEG and RapidTEG components further indicates that these methodologies are insensitive to warfarin effects. Findings suggest that intrinsic pathway activation may mitigate detection of an extrinsic pathway coagulopathy

    Comparative Geno-Plasticity Analysis of Mycoplasma bovis HB0801 (Chinese Isolate)

    Get PDF
    Mycoplasma bovis pneumonia in cattle has been epidemic in China since 2008. To investigate M. bovis pathogenesis, we completed genome sequencing of strain HB0801 isolated from a lesioned bovine lung from Hubei, China. The genomic plasticity was determined by comparing HB0801 with M. bovis strain ATCC® 25523™/PG45 from cow mastitis milk, Chinese strain Hubei-1 from lesioned lung tissue, and 16 other Mycoplasmas species. Compared to PG45, the genome size of HB0801 was reduced by 11.7 kb. Furthermore, a large chromosome inversion (580 kb) was confirmed in all Chinese isolates including HB0801, HB1007, a strain from cow mastitis milk, and Hubei-1. In addition, the variable surface lipoproteins (vsp) gene cluster existed in HB0801, but contained less than half of the genes, and had poor identity to that in PG45, but they had conserved structures. Further inter-strain comparisons revealed other mechanisms of gene acquisition and loss in HB0801 that primarily involved insertion sequence (IS) elements, integrative conjugative element, restriction and modification systems, and some lipoproteins and transmembrane proteins. Subsequently, PG45 and HB0801 virulence in cattle was compared. Results indicated that both strains were pathogenic to cattle. The scores of gross pathological assessment for the control group, and the PG45- and HB0801-infected groups were 3, 13 and 9, respectively. Meanwhile the scores of lung lesion for these three groups were 36, 70, and 69, respectively. In addition, immunohistochemistry detection demonstrated that both strains were similarly distributed in lungs and lymph nodes. Although PG45 showed slightly higher virulence in calves than HB0801, there was no statistical difference between the strains (P>0.05). Compared to Hubei-1, a total of 122 SNP loci were disclosed in HB0801. In conclusion, although genomic plasticity was thought to be an evolutionary advantage, it did not apparently affect virulence of M. bovis strains in cattle

    ATLAS liquid argon calorimeter front end electronics

    Get PDF
    The ATLAS detector has been designed for operation at CERN's Large Hadron Collider. ATLAS includes a complex system of liquid argon calorimeters. This paper describes the architecture and implementation of the system of custom front end electronics developed for the readout of the ATLAS liquid argon calorimeters

    Legal Institutions, Legal Origins, and Governance

    Full text link
    corecore