2,565 research outputs found

    Natural radiactivity from building materials in Spain

    Get PDF
    The industrial construction sector is very important in Spain. Building materials used in this industry are sources of radiation from natural radionuclides they contain. The European Commission published some recommendations to facilitate the trade of these materials in the E.U. The studies about this subject have increased notably during last years. This, probably, can be associated with the increase interest from natural radiation radiological risk on indoor exposure.Universidad de Málaga. Campus de Excelencia Internacional Andalucía Tech. Consejo de Seguridad Nuclear. CSN-201

    Structural characterization and electrochemical behavior of transition metal carbonates

    Get PDF
    III Encuentro sobre Nanociencia y Nanotecnología de Investigadores y Tecnólogos Andaluce

    Un nuevo método de sintesis del carbonato de manganeso como electrodo negativo en baterías de ión-litio

    Get PDF
    III Encuentro sobre Nanociencia y Nanotecnología de Investigadores y Tecnólogos Andaluce

    Oxalatos mixtos de metales de transición y capacidades no-faradaicas para electrodos negativos en baterías de ión-litio

    Get PDF
    II Encuentro sobre nanociencia y nanotecnología de investigadores y tecnólogos de la Universidad de Córdoba. NANOUC

    Symmetries in Classical Field Theory

    Full text link
    The multisymplectic description of Classical Field Theories is revisited, including its relation with the presymplectic formalism on the space of Cauchy data. Both descriptions allow us to give a complete scheme of classification of infinitesimal symmetries, and to obtain the corresponding conservation laws.Comment: 70S05; 70H33; 55R10; 58A2

    Prótesis modular de cadera Poropalcar : resultados clínicos en 106 pacientes con 3 años de evolución

    Get PDF
    Los resultados tras reemplazamiento total de cadera con prótesis de superficie porometal «poropros», para fijación biológica, han sido evaluados en 106 pacientes después de tres años de evolución. La valoración clínica se ha realizado según el sistema de Harris modificado, obteniendo un 91,5% de buenos resultados y un 8,5% de resultados regulares incluyendo todos los enfermos de cualquier edad y patología. El estudio realizado a partir de parámetros clínicos y radiográficos permite apreciar una buena fijación primaria de la prótesis y una excelente estabilidad de la misma, tanto para el componente femoral como cotiloideo.In a series of 106 patients who undewent porocoated total hip arthroplasty, the results were evaluated after three years follow-up. Harris'score was used for clinical assesment, obtaining 91,5% of good results and 8,5% of fair results, including all the cases whichever aetiology and age. Clinical and radiographic studies showed a good primary fixation and excellent stability in both the acetabular and the femoral stem components

    Acaricide resistance of Rhipicephalus (Boophilus) microplus in State of Mato Grosso do Sul, Brazil.

    Get PDF
    This study was conducted to obtain an epidemiological view of acaricide resistance in populations of Rhipicephalus (Boophilus) microplus in the State of Mato Grosso do Sul. Twenty-four tick samples were collected from municipalities in the State where farmers had reported concerns about resistance to or failure of tick control. These ticks were subjected to in vitro resistance detection assays using the adult immersion test (AIT). The efficacy of alpha-cypermethrin, cypermethrin and amitraz treatments on samples collected throughout the State was generally poor. AIT showed efficacy ≥ 90% from the use of DDVP + chlorfenvinphos) (20 out of 21 municipalities), dichlorvos + cypermethrin (10 out of 16 municipalities) and cypermethrin + citronella + chlorpyrifos + piperonyl butoxide (20 out of 21 municipalities). PCR assays were used to detect the presence of pyrethroid resistance-associated sodium channel gene mutation. Larvae from three different populations that had previously been diagnosed as pyrethroid-resistant, through AIT, were evaluated. The PCR assays showed that the pyrethroid resistance-associated gene mutation was absent from these three populations. This study confirms that the emergence of resistance is a constant challenge for the livestock industry, and that development of resistance continues to be a major driver for new antiparasitic drugs to be developed

    Influence of occlusal collision corrections completed by two intraoral scanners or a dental design program on the accuracy of the maxillomandibular relationship.

    Get PDF
    STATEMENT OF PROBLEM Occlusal collisions of articulated intraoral digital scans can be corrected by intraoral scanners (IOSs) or dental design software programs. However, the influence of these corrections on the accuracy of maxillomandibular relationship is unclear. PURPOSE The purpose of this clinical investigation was to measure the effect of occlusal collision corrections completed by the IOSs or dental design software programs on the trueness and precision of maxillomandibular relationship. MATERIAL AND METHODS Casts of a participant mounted on an articulator were digitized (T710). The experimental scans were obtained by using 2 IOSs: TRIOS4 and i700. The intraoral digital scans of the maxillary and mandibular arches were obtained and duplicated 15 times. For each duplicated pair of scans, a bilateral virtual occlusal record was acquired. Articulated specimens were duplicated and assigned into 2 groups: IOS-not corrected and IOS corrected (n=15). In the IOS-not corrected groups, the IOS software program postprocessed the scans maintaining the occlusal collisions, while in the IOS-corrected groups, the IOS software program eliminated the occlusal collisions. All articulated specimens were imported into a computer-aided design (CAD) program (DentalCAD). Three subgroups were developed based on the CAD correction: CAD-no change, trimming, or opening the vertical dimension. Thirty-six interlandmark distances were measured on the reference and each experimental scan to compute discrepancies by using a software program (Geomagic Wrap). Root mean square (RMS) was selected to compute the cast modifications performed in the trimming subgroups. Trueness was examined using 2-way ANOVA and pairwise comparison Tukey tests (α=.05). Precision was evaluated with the Levene test (α=.05). RESULTS The IOS (P<.001), the program (P<.001), and their interaction (P<.001) impacted the trueness of the maxillomandibular relationship. The i700 obtained higher trueness than the TRIOS4 (P<.001). The IOS-not corrected-CAD-no-changes and IOS-not-corrected-trimming subgroups obtained the lowest trueness (P<.001), while the IOS-corrected-CAD-no-changes, IOS-corrected-trimming, and IOS-corrected-opening subgroups showed the highest trueness (P<.001). No significant differences in precision were found (P<.001). Furthermore, significant RMS differences were found (P<.001), with a significant interaction between Group×Subgroup (P<.001). The IOS-not corrected-trimmed subgroups obtained a significantly higher RMS error discrepancy than IOS-corrected-trimmed subgroups (P<.001). The Levene test showed a significant discrepancy in the RMS precision among IOSs across subgroups (P<.001). CONCLUSIONS The trueness of the maxillomandibular relationship was influenced by the scanner and program used to correct occlusal collisions. Better trueness was obtained when the occlusal collisions were adjusted by the IOS program compared with the CAD program. Precision was not significantly influenced by the occlusal collision correction method. CAD corrections did not improve the results of the IOS software. Additionally, the trimming option caused volumetric changes on the occlusal surfaces of intraoral scans
    corecore