184 research outputs found

    Height-resolved Scaling Properties of Tropospheric Water Vapour based on Airborne Lidar Observations

    Get PDF
    Two-dimensional vertical water vapour cross sections of the free troposphere between altitudes of 2 and 10 km, measured by nadir-viewing airborne differential-absorption lidar with high spatial resolution, were analyzed using structure functions up to the fifth order. We found scale invariance, i.e. a power-law dependency of structure function on length scale, for scales between 5 and 100 km, for the horizontal time series of water vapour mixing ratio. In contrast to one-dimensional in situ measurements, the two-dimensional water vapor lidar observations allow height-resolved analyses of power-law scaling exponents at a vertical resolution of 200 m. The data reveal significantly different scaling properties above and below an air-mass boundary. They stem from three very dissimilar aircraft campaigns: COPS/ETReC over middle and southern Europe in summer 2007, T-PARC around Japan mostly over sea in late summer 2008, and T-IPY around Spitsbergen over sea in winter 2008. After discarding flight segments with low lidar signals or large data gaps, and after averaging horizontally to a resolution of between 1 and 5 km to obtain a high signal to noise ratio, structure functions were computed for 20 flights at various heights, adding up to a length of more than 300,000 km. The power-law scaling exponents of the structure functions do not show significant latitudinal, seasonal or land/sea dependency, but they do differ between air masses influenced by moist convection and air masses aloft, not influenced. A classification of the horizontal water vapour time series into two groups according to whether the series occurred above or below the level of nearby convective cloud tops could be performed by detecting the cloud top height from the lidar backscatter signal in the corresponding flight segment. We found that the scaling exponents can be divided into two groups depending on the respective air mass: The smoothness of the time series, expressed by the first-order scaling exponent, varies from less than 0.5 in the low-level convectively influenced air masses to values greater than 0.5 and most frequently near 0.6 in the higher-level air above the convective cloud tops. The time series’ intermittency, expressed by the variation of the scaling exponent with increasing order, is larger in convectively influenced air masses. These differences in variability strongly suggest that convection provides a source of moisture variability on small scales. Our results show that the high horizontal and vertical resolution of lidar observations allows a characterisation of the scale dependency of the water vapour field at scales close to and smaller than the smallest resolved scales in modern weather and climate models. This provides both a reference for validation of high resolution models and a basis for the design of stochastic or pdf-based parameterisations of clouds and convection

    Sensitivity studies for a space-based methane lidar mission

    Get PDF
    Methane is the third most important greenhouse gas in the atmosphere after water vapour and carbon dioxide. A major handicap to quantify the emissions at the Earth's surface in order to better understand biosphere-atmosphere exchange processes and potential climate feedbacks is the lack of accurate and global observations of methane. Space-based integrated path differential absorption (IPDA) lidar has potential to fill this gap, and a Methane Remote Lidar Mission (MERLIN) on a small satellite in polar orbit was proposed by DLR and CNES in the frame of a German-French climate monitoring initiative. System simulations are used to identify key performance parameters and to find an advantageous instrument configuration, given the environmental, technological, and budget constraints. The sensitivity studies use representative averages of the atmospheric and surface state to estimate the measurement precision, i.e. the random uncertainty due to instrument noise. Key performance parameters for MERLIN are average laser power, telescope size, orbit height, surface reflectance, and detector noise. A modest-size lidar instrument with 0.45 W average laser power and 0.55 m telescope diameter on a 506 km orbit could provide 50-km averaged methane column measurement along the sub-satellite track with a precision of about 1% over vegetation. The use of a methane absorption trough at 1.65 Îźm improves the near-surface measurement sensitivity and vastly relaxes the wavelength stability requirement that was identified as one of the major technological risks in the pre-phase A studies for A-SCOPE, a space-based IPDA lidar for carbon dioxide at the European Space Agency. Minimal humidity and temperature sensitivity at this wavelength position will enable accurate measurements in tropical wetlands, key regions with largely uncertain methane emissions. In contrast to actual passive remote sensors, measurements in Polar Regions will be possible and biases due to aerosol layers and thin ice clouds will be minimised

    Passive remote sensing of columnar water vapour content above land surfaces. Part I: Theoretical algorithm development - Part II: Comparison of OVID measurements with radiosonde and DIAL measurements

    Get PDF
    Various efforts are currently being made to develop remote sensing techniques for high accuracy determination of atmospheric columnar water vapour content above land surfaces. Most of those algorithms are based on radiative transfer calcu lations, however, which have to be verified by spectral airborne or satellite measurements. Initial verification of a new algorithm with the aid of airborne spectral data using the spectrometer OVID (Optical Visible and near Infrared Detector), an airborne water vapour DIAL (Differential Absorption Lidar), an airc;raft humicap sensor and radiosonde data is performed dUIing a flight experiment over Southern Germany. This water vapour algorithm is also dedicated to the MERIS (MEdium Resolution Imaging Spectrometer) in strument on board ESA's satellite ENVISAT which will be launched 1999. Spatial water vapour gradients of &120 = 0.1 g/cm2 over a distance of 100 km were resolved by applying the OVID measurements. The error estimation of the absolute value of the retrieved water vapour contents poses¡ some problems due to insufficient additional temporal and spatial radiosonde data. However, the principal feasibility has been prove

    First airborne water vapor lidar measurements in the tropical upper troposphere and mid-latitudes lower stratosphere: accuracy evaluation and intercomparisons with other instruments

    Get PDF
    In the tropics, deep convection is the major source of uncertainty in water vapor transport to the upper troposphere and into the stratosphere. Although accurate measurements in this region would be of first order importance to better understand the processes that govern stratospheric water vapor concentrations and trends in the context of a changing climate, they are sparse because of instrumental shortcomings and observational challenges. Therefore, the Falcon research aircraft of the Deutsches Zentrum fĂźr Luft- und Raumfahrt (DLR) flew a zenith-viewing water vapor differential absorption lidar (DIAL) during the Tropical Convection, Cirrus and Nitrogen Oxides Experiment (TROCCINOX) in 2004 and 2005 in Brazil. The measurements were performed alternatively on three water vapor absorption lines of different strength around 940 nm. These are the first aircraft DIAL measurements in the tropical upper troposphere and in the mid-latitudes lower stratosphere. Sensitivity analyses reveal an accuracy of 5% between altitudes of 8 and 16 km. This is confirmed by intercomparisons with the Fast In-situ Stratospheric Hygrometer (FISH) and the Fluorescent Advanced Stratospheric Hygrometer (FLASH) onboard the Russian M-55 Geophysica research aircraft during five coordinated flights. The average relative differences between FISH and DIAL amount to −3%±8% and between FLASH and DIAL to −8%±14%, negative meaning DIAL is more humid. The average distance between the probed air masses was 129 km. The DIAL is found to have no altitude- or latitude-dependent bias. A comparison with the balloon ascent of a laser absorption spectrometer gives an average difference of 0%±19% at a distance of 75 km. Six tropical DIAL under-flights of the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) on board ENVISAT reveal a mean difference of −8%±49% at an average distance of 315 km. While the comparison with MIPAS is somewhat less significant due to poorer comparison conditions, the agreement with the in-situ hygrometers provides evidence of the excellent quality of FISH, FLASH and DIAL. Most DIAL profiles exhibit a smooth exponential decrease of water vapor mixing ratio in the tropical upper troposphere to lower stratosphere transition. The hygropause with a minimum mixing ratio of 2.5 µmol/mol is found between 15 and 17 km. A high-resolution (2 km horizontal, 0.2 km vertical) DIAL cross section through the anvil outflow of tropical convection shows that the ambient humidity is increased by a factor of three across 100 km

    Mixing of mineral dust with urban pollution aerosol over Dakar (Senegal): Impact on dust physico-chemical and radiative properties.

    Get PDF
    In the framework of the Saharan Mineral Dust Experiment (SAMUM) in 2008, the mixing of the urban pollution plume of Dakar (Senegal) with mineral dust was studied in detail using the German research aircraft Falcon which was equipped with a nadir-looking high spectral resolution lidar (HSRL) and extensive aerosol in situ instrumentation. The mineral dust layer as well as the urban pollution plume were probed remotely by the HSRL and in situ. Back trajectory analyses were used to attribute aerosol samples to source regions.We found that the emission from the region of Dakar increased the aerosol optical depth (532 nm) from approximately 0.30 over sea and over land east of Dakar to 0.35 in the city outflow. In the urban area, local black carbon (BC) emissions, or soot respectively, contributed more than 75% to aerosol absorption at 530 nm. In the dust layer, the single-scattering albedo at 530 nm was 0.96 â�� 0.99, whereas we found a value of 0.908 �± 0.018 for the aerosol dominated by urban pollution. After 6h of transport over the North Atlantic, the externally mixed mode of secondary aerosol particles had almost completely vanished, whereas the BC agglomerates (soot) were still externally mixed with mineral dust particles

    Ultrathin Tropical Tropopause Clouds (UTTCs) : I. Cloud morphology and occurrence

    Get PDF
    Subvisible cirrus clouds (SVCs) may contribute to dehydration close to the tropical tropopause. The higher and colder SVCs and the larger their ice crystals, the more likely they represent the last efficient point of contact of the gas phase with the ice phase and, hence, the last dehydrating step, before the air enters the stratosphere. The first simultaneous in situ and remote sensing measurements of SVCs were taken during the APE-THESEO campaign in the western Indian ocean in February/March 1999. The observed clouds, termed Ultrathin Tropical Tropopause Clouds (UTTCs), belong to the geometrically and optically thinnest large-scale clouds in the Earth´s atmosphere. Individual UTTCs may exist for many hours as an only 200--300 m thick cloud layer just a few hundred meters below the tropical cold point tropopause, covering up to 105 km2. With temperatures as low as 181 K these clouds are prime representatives for defining the water mixing ratio of air entering the lower stratosphere

    An interdisciplinary approach to the study of kiln firing: a case study from the Campus Galli open-air museum (southern Germany)

    Get PDF
    Pottery kilns are a common feature in the archaeological record of different periods. However, these pyrotechnological installations are still seldom the target of interdisciplinary investigations. To fill this gap in our knowledge, an updraft kiln firing experiment was run at the Campus Galli open-air museum (southern Germany) by a team consisting of experimental archaeologists, material scientists, geoarchaeologists, and palaeobotanists. The entire process from the preparation of the raw materials to the firing and opening of the kiln was carefully recorded with a particular focus on the study of the raw materials used for pottery making, as well as on fuel usage. The temperatures were monitored by thermocouples placed at different positions in the combustion and firing chambers. In addition, thermocouples were installed within the kiln wall to measure the temperature distribution inside the structure itself. Unfired raw materials as well as controlled and experimentally thermally altered ceramic samples were then characterised with an integrated analysis including ceramic petrography, X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), and portable X-ray fluorescence (pXRF). Our work provides data about mineralogical and microstructural developments in both pottery kiln structures and the ceramics produced in this type of installations. This is helpful to discuss the limits and potential of various scientific analyses commonly used in ancient ceramic pyrotechnological studies. Overall, our work contributes to a better understanding of updraft kiln technology and offers guidelines on how to address the study of this type of pyrotechnological installations using interdisciplinary research strategies
    • …
    corecore