10,363 research outputs found

    G0^0 Electronics and Data Acquisition (Forward-Angle Measurements)

    Get PDF
    The G0^0 parity-violation experiment at Jefferson Lab (Newport News, VA) is designed to determine the contribution of strange/anti-strange quark pairs to the intrinsic properties of the proton. In the forward-angle part of the experiment, the asymmetry in the cross section was measured for ep\vec{e}p elastic scattering by counting the recoil protons corresponding to the two beam-helicity states. Due to the high accuracy required on the asymmetry, the G0^0 experiment was based on a custom experimental setup with its own associated electronics and data acquisition (DAQ) system. Highly specialized time-encoding electronics provided time-of-flight spectra for each detector for each helicity state. More conventional electronics was used for monitoring (mainly FastBus). The time-encoding electronics and the DAQ system have been designed to handle events at a mean rate of 2 MHz per detector with low deadtime and to minimize helicity-correlated systematic errors. In this paper, we outline the general architecture and the main features of the electronics and the DAQ system dedicated to G0^0 forward-angle measurements.Comment: 35 pages. 17 figures. This article is to be submitted to NIM section A. It has been written with Latex using \documentclass{elsart}. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment In Press (2007

    Bioactive supramolecular peptide nanofibers for regenerative medicine

    Get PDF
    Cataloged from PDF version of article.Recent advances in understanding of cell-matrix interactions and the role of the extracellular matrix (ECM) in regulation of cellular behavior have created new perspectives for regenerative medicine. Supramolecular peptide nanofiber systems have been used as synthetic scaffolds in regenerative medicine applications due to their tailorable properties and ability to mimic ECM proteins. Through designed bioactive epitopes, peptide nanofiber systems provide biomolecular recognition sites that can trigger specific interactions with cell surface receptors. The present Review covers structural and biochemical properties of the self-assembled peptide nanofibers for tissue regeneration, and highlights studies that investigate the ability of ECM mimetic peptides to alter cellular behavior including cell adhesion, proliferation, and/or differentiation. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim

    Size-controlled conformal nanofabrication of biotemplated three-dimensional TiO2 and ZnO nanonetworks

    Get PDF
    Cataloged from PDF version of article.A solvent-free fabrication of TiO2 and ZnO nanonetworks is demonstrated by using supramolecular nanotemplates with high coating conformity, uniformity, and atomic scale size control. Deposition of TiO2 and ZnO on three-dimensional nanofibrous network template is accomplished. Ultrafine control over nanotube diameter allows robust and systematic evaluation of the electrochemical properties of TiO2 and ZnO nanonetworks in terms of size-function relationship. We observe hypsochromic shift in UV absorbance maxima correlated with decrease in wall thickness of the nanotubes. Photocatalytic activities of anatase TiO2 and hexagonal wurtzite ZnO nanonetworks are found to be dependent on both the wall thickness and total surface area per unit of mass. Wall thickness has effect on photoexcitation properties of both TiO2 and ZnO due to band gap energies and total surface area per unit of mass. The present work is a successful example that concentrates on nanofabrication of intact three-dimensional semiconductor nanonetworks with controlled band gap energies

    First events from the CNGS neutrino beam detected in the OPERA experiment

    Get PDF
    The OPERA neutrino detector at the underground Gran Sasso Laboratory (LNGS) was designed to perform the first detection of neutrino oscillations in appearance mode, through the study of nu_mu to nu_tau oscillations. The apparatus consists of a lead/emulsion-film target complemented by electronic detectors. It is placed in the high-energy, long-baseline CERN to LNGS beam (CNGS) 730 km away from the neutrino source. In August 2006 a first run with CNGS neutrinos was successfully conducted. A first sample of neutrino events was collected, statistically consistent with the integrated beam intensity. After a brief description of the beam and of the various sub-detectors, we report on the achievement of this milestone, presenting the first data and some analysis results.Comment: Submitted to the New Journal of Physic

    A Spectroscopic Survey of a Sample of Active M Dwarfs

    Get PDF
    A moderate resolution spectroscopic survey of Fleming's sample of 54 X-ray selected M dwarfs with photometric distances less than 25 pc is presented. Radial and rotation velocities have been measured by fits to the H-alpha profiles. Radial velocities have been measured by cross correlation. Artificial broadening of an observed spectrum has produced a relationship between H-alpha FWHM and rotation speed, which we use to infer rotation speeds for the entire sample by measurement of the H-alpha emission line. We find 3 ultra-fast rotators (UFRs, vsini > 100km/s), and 8 stars with 30 < vsini < 100 km/s. The UFRs have variable emission. Cross-correlation velocities measured for ultra-fast rotators (UFRs) are shown to depend on rotation speed and the filtering used. The radial velocity dispersion of the sample is 17 km/s. A new double emission line spectroscopic binary with a period of 3.55 days has been discovered, and another known one is in the sample. Three other objects are suspected spectroscopic binaries, and at least six are visual doubles. The only star in the sample observed to have significant lithium is a known TW Hya Association member, TWA 8A. These results show that there are a number of young (< 10^8 yr) and very young (< 10^7 yr) low mass stars in the immediate solar neighbourhood. The H-alpha activity strength does not depend on rotation speed. Our fast rotators are less luminous than similarly fast rotators in the Pleiades. They are either younger than the Pleiades, or gained angular momentum in a different way.Comment: 38 pages incl. 14 figures and 4 tables, plus 12 pages of table for electronic journal only; LaTeX, aastex.cls. Accepted 07/18/02 for publication in The Astronomical Journa

    Observation of nu_tau appearance in the CNGS beam with the OPERA experiment

    Get PDF
    The OPERA experiment is searching for nu_mu -> nu_tau oscillations in appearance mode i.e. via the direct detection of tau leptons in nu_tau charged current interactions. The evidence of nu_mu -> nu_tau appearance has been previously reported with three nu_tau candidate events using a sub-sample of data from the 2008-2012 runs. We report here a fourth nu_tau candidate event, with the tau decaying into a hadron, found after adding the 2012 run events without any muon in the final state to the data sample. Given the number of analysed events and the low background, nu_mu -> nu_tau oscillations are established with a significance of 4.2sigma.Comment: Submitted to Progress of Theoretical and Experimental Physics (PTEP

    Determination of the muon charge sign with the dipolar spectrometers of the OPERA experiment

    Full text link
    The OPERA long-baseline neutrino-oscillation experiment has observed the direct appearance of ντ\nu_\tau in the CNGS νμ\nu_\mu beam. Two large muon magnetic spectrometers are used to identify muons produced in the τ\tau leptonic decay and in νμCC\nu_\mu^{CC} interactions by measuring their charge and momentum. Besides the kinematic analysis of the τ\tau decays, background resulting from the decay of charmed particles produced in νμCC\nu_\mu^{CC} interactions is reduced by efficiently identifying the muon track. A new method for the charge sign determination has been applied, via a weighted angular matching of the straight track-segments reconstructed in the different parts of the dipole magnets. Results obtained for Monte Carlo and real data are presented. Comparison with a method where no matching is used shows a significant reduction of up to 40\% of the fraction of wrongly determined charges.Comment: 10 pages. Improvements in the tex
    corecore