Behavioural and transcriptional changes in the amphipod <i>Echinogammarus marinus</i> exposed to two antidepressants, fluoxetine and sertraline
G Electronics and Data Acquisition (Forward-Angle Measurements)
The G parity-violation experiment at Jefferson Lab (Newport News, VA) is
designed to determine the contribution of strange/anti-strange quark pairs to
the intrinsic properties of the proton. In the forward-angle part of the
experiment, the asymmetry in the cross section was measured for
elastic scattering by counting the recoil protons corresponding to the two
beam-helicity states. Due to the high accuracy required on the asymmetry, the
G experiment was based on a custom experimental setup with its own
associated electronics and data acquisition (DAQ) system. Highly specialized
time-encoding electronics provided time-of-flight spectra for each detector for
each helicity state. More conventional electronics was used for monitoring
(mainly FastBus). The time-encoding electronics and the DAQ system have been
designed to handle events at a mean rate of 2 MHz per detector with low
deadtime and to minimize helicity-correlated systematic errors. In this paper,
we outline the general architecture and the main features of the electronics
and the DAQ system dedicated to G forward-angle measurements.Comment: 35 pages. 17 figures. This article is to be submitted to NIM section
A. It has been written with Latex using \documentclass{elsart}. Nuclear
Instruments and Methods in Physics Research Section A: Accelerators,
Spectrometers, Detectors and Associated Equipment In Press (2007
Bioactive supramolecular peptide nanofibers for regenerative medicine
Cataloged from PDF version of article.Recent advances in understanding of cell-matrix interactions and the role of the extracellular matrix (ECM) in regulation of cellular behavior have created new perspectives for regenerative medicine. Supramolecular peptide nanofiber systems have been used as synthetic scaffolds in regenerative medicine applications due to their tailorable properties and ability to mimic ECM proteins. Through designed bioactive epitopes, peptide nanofiber systems provide biomolecular recognition sites that can trigger specific interactions with cell surface receptors. The present Review covers structural and biochemical properties of the self-assembled peptide nanofibers for tissue regeneration, and highlights studies that investigate the ability of ECM mimetic peptides to alter cellular behavior including cell adhesion, proliferation, and/or differentiation. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim
Size-controlled conformal nanofabrication of biotemplated three-dimensional TiO2 and ZnO nanonetworks
Cataloged from PDF version of article.A solvent-free fabrication of TiO2 and ZnO nanonetworks is demonstrated by using supramolecular nanotemplates with high coating conformity, uniformity, and atomic scale size control. Deposition of TiO2 and ZnO on three-dimensional nanofibrous network template is accomplished. Ultrafine control over nanotube diameter allows robust and systematic evaluation of the electrochemical properties of TiO2 and ZnO nanonetworks in terms of size-function relationship. We observe hypsochromic shift in UV absorbance maxima correlated with decrease in wall thickness of the nanotubes. Photocatalytic activities of anatase TiO2 and hexagonal wurtzite ZnO nanonetworks are found to be dependent on both the wall thickness and total surface area per unit of mass. Wall thickness has effect on photoexcitation properties of both TiO2 and ZnO due to band gap energies and total surface area per unit of mass. The present work is a successful example that concentrates on nanofabrication of intact three-dimensional semiconductor nanonetworks with controlled band gap energies
First events from the CNGS neutrino beam detected in the OPERA experiment
The OPERA neutrino detector at the underground Gran Sasso Laboratory (LNGS)
was designed to perform the first detection of neutrino oscillations in
appearance mode, through the study of nu_mu to nu_tau oscillations. The
apparatus consists of a lead/emulsion-film target complemented by electronic
detectors. It is placed in the high-energy, long-baseline CERN to LNGS beam
(CNGS) 730 km away from the neutrino source. In August 2006 a first run with
CNGS neutrinos was successfully conducted. A first sample of neutrino events
was collected, statistically consistent with the integrated beam intensity.
After a brief description of the beam and of the various sub-detectors, we
report on the achievement of this milestone, presenting the first data and some
analysis results.Comment: Submitted to the New Journal of Physic
A Spectroscopic Survey of a Sample of Active M Dwarfs
A moderate resolution spectroscopic survey of Fleming's sample of 54 X-ray
selected M dwarfs with photometric distances less than 25 pc is presented.
Radial and rotation velocities have been measured by fits to the H-alpha
profiles. Radial velocities have been measured by cross correlation. Artificial
broadening of an observed spectrum has produced a relationship between H-alpha
FWHM and rotation speed, which we use to infer rotation speeds for the entire
sample by measurement of the H-alpha emission line. We find 3 ultra-fast
rotators (UFRs, vsini > 100km/s), and 8 stars with 30 < vsini < 100 km/s. The
UFRs have variable emission. Cross-correlation velocities measured for
ultra-fast rotators (UFRs) are shown to depend on rotation speed and the
filtering used. The radial velocity dispersion of the sample is 17 km/s. A new
double emission line spectroscopic binary with a period of 3.55 days has been
discovered, and another known one is in the sample. Three other objects are
suspected spectroscopic binaries, and at least six are visual doubles. The only
star in the sample observed to have significant lithium is a known TW Hya
Association member, TWA 8A. These results show that there are a number of young
(< 10^8 yr) and very young (< 10^7 yr) low mass stars in the immediate solar
neighbourhood. The H-alpha activity strength does not depend on rotation speed.
Our fast rotators are less luminous than similarly fast rotators in the
Pleiades. They are either younger than the Pleiades, or gained angular momentum
in a different way.Comment: 38 pages incl. 14 figures and 4 tables, plus 12 pages of table for
electronic journal only; LaTeX, aastex.cls. Accepted 07/18/02 for publication
in The Astronomical Journa
Observation of nu_tau appearance in the CNGS beam with the OPERA experiment
The OPERA experiment is searching for nu_mu -> nu_tau oscillations in
appearance mode i.e. via the direct detection of tau leptons in nu_tau charged
current interactions. The evidence of nu_mu -> nu_tau appearance has been
previously reported with three nu_tau candidate events using a sub-sample of
data from the 2008-2012 runs. We report here a fourth nu_tau candidate event,
with the tau decaying into a hadron, found after adding the 2012 run events
without any muon in the final state to the data sample. Given the number of
analysed events and the low background, nu_mu -> nu_tau oscillations are
established with a significance of 4.2sigma.Comment: Submitted to Progress of Theoretical and Experimental Physics (PTEP
Determination of the muon charge sign with the dipolar spectrometers of the OPERA experiment
The OPERA long-baseline neutrino-oscillation experiment has observed the
direct appearance of in the CNGS beam. Two large muon
magnetic spectrometers are used to identify muons produced in the
leptonic decay and in interactions by measuring their charge and
momentum. Besides the kinematic analysis of the decays, background
resulting from the decay of charmed particles produced in
interactions is reduced by efficiently identifying the muon track. A new method
for the charge sign determination has been applied, via a weighted angular
matching of the straight track-segments reconstructed in the different parts of
the dipole magnets. Results obtained for Monte Carlo and real data are
presented. Comparison with a method where no matching is used shows a
significant reduction of up to 40\% of the fraction of wrongly determined
charges.Comment: 10 pages. Improvements in the tex
- …