138 research outputs found

    Nanostructured Melt-Spun Sm(Co,Fe,Zr,B)7:5 Alloys for High-Temperature Magnets

    Full text link
    High coercivity, the highest for Cu-free 2 : 17 Sm-Co ribbons, has been obtained in as-spun (= 211 kOe) and short time annealed (= 232 kOe) samples of Sm(CobalFe Zr B)7 5 alloys, with varying B, Zr, and Fe content (= 0-0 06, = 0-0 16, = 0 08-0 3) and wheel speed. In as-spun samples, the TbCu7 type structure and in annealed samples the Th2Zn17 and CaCu5 type structures is observed, plus fcc Co as minority phase is observed. Reduced remanence () is higher than 0.7. High-temperature magnetic measurements show very good stability above 300 C with coercive field as high as 5.2 kOe at 330 C. For annealed Sm(CobalFe0 3Zr0 02B0 04)7 5, very good loop squareness and high maximum energy product of 10.7 MGOe have been obtained. Increasing Zr content results in less uniform microstructure of annealed ribbons.Comment: IEEE Transactions on Magnetics, Vol. 39, No. 5, pages 2869 - 2871, September 200

    a term is known by the company it keeps”: On selecting a good expansion set in pseudo-relevance feedback

    Get PDF
    Abstract. It is well known that pseudo-relevance feedback (PRF) improves the retrieval performance of Information Retrieval (IR) systems in general. However, a recent study by Cao et al [3] has shown that a non-negligible fraction of expansion terms used by PRF algorithms are harmful to the retrieval. In other words, a PRF algorithm would be better off if it were to use only a subset of the feedback terms. The challenge then is to find a good expansion set from the set of all candidate expansion terms. A natural approach to solve the problem is to make term independence assumption and use one or more term selection criteria or a statistical classifier to identify good expansion terms independent of each other. In this work, we challenge this approach and show empirically that a feedback term is neither good nor bad in itself in general; the behavior of a term depends very much on other expansion terms. Our finding implies that a good expansion set can not be found by making term independence assumption in general. As a principled solution to the problem, we propose spectral partitioning of expansion terms using a specific term-term interaction matrix. We demonstrate on several test collections that expansion terms can be partitioned into two sets and the best of the two sets gives substantial improvements in retrieval performance over model-based feedback

    Methods of sputum processing for cell counts, immunocytochemistry and in situ hybridisation.

    Get PDF
    Since the first attempts to use standardised methods for sampling induced airways sputum, two methods for processing the expectorate have evolved. The first involves selecting all viscid or denser portions from the expectorated sample with the aid of an inverted microscope. This method has been extensively evaluated and reported in detail. The second approach involves processing the entire expectorate, comprising sputum plus variable amounts of saliva. Recent modifications to this method include collecting saliva and sputum separately in order to reduce salivary contamination. Both methods have advantages and disadvantages. The advantages of using selected sputum are: squamous cell contamination is v5%, making cell counting easier and quicker to perform, the total cell count (TCC) can be expressed per gram of lower airway secretions, and concentrations of chemicals in the fluid phase are unaffected by the confounding influence of saliva, and can be accurately corrected for dilution. The disadvantage is that selection takes a few minutes longer to perform and requires an inverted microscope. The advantage of using the entire expectorate is that the technique is quicker to perform, but there are some disadvantages that require consideration. The expectorate contains a variable mixture of sputum plus saliva which maydilute the sputum and confound its analysis. The reproducibility of cell counts has been reported to be lower if squamous cell contamination represents w20% of all recovered cells. There is conflicting data as to whether or not differential cell counts (DCCs) differ between the two methods. One study reported a higher percentage of eosinophils in sputum processed by the selection method compared to the entire expectorate but this has not been confirmed in other studies. Although, both the selected sputum and the entire expectorate methods have the same ability to distinguish asthmatics or bronchitics from healthy subjects, they are not interchangeable, and, once a technique has been adopted for a given study, it should always be applied

    A Novel Combined Term Suggestion Service for Domain-Specific Digital Libraries

    Full text link
    Interactive query expansion can assist users during their query formulation process. We conducted a user study with over 4,000 unique visitors and four different design approaches for a search term suggestion service. As a basis for our evaluation we have implemented services which use three different vocabularies: (1) user search terms, (2) terms from a terminology service and (3) thesaurus terms. Additionally, we have created a new combined service which utilizes thesaurus term and terms from a domain-specific search term re-commender. Our results show that the thesaurus-based method clearly is used more often compared to the other single-method implementations. We interpret this as a strong indicator that term suggestion mechanisms should be domain-specific to be close to the user terminology. Our novel combined approach which interconnects a thesaurus service with additional statistical relations out-performed all other implementations. All our observations show that domain-specific vocabulary can support the user in finding alternative concepts and formulating queries.Comment: To be published in Proceedings of Theories and Practice in Digital Libraries (TPDL), 201

    Assessment of a rapid liquid-based cytology method for measuring sputum cell counts

    Get PDF
    Differential sputum cell counting is not widely available despite proven clinical utility in the management of asthma. We compared eosinophil counts obtained using liquid-based cytology (LBC), a routine histopathological processing method, and the current standard method. Eosinophil counts obtained using LBC were a strong predictor of sputum eosinophilia (≥3%) determined by the standard method suggesting LBC could be used in the management of asthma

    Совершенствование технологии сооружения подводных переходов трубопроводов проложенных методом горизонтально-направленного бурения

    Get PDF
    Цель работы – разработка рекомендаций по применению технологии прокладки трубопроводов методом горизонтально-направленного бурения с применением защитного устройства. В процессе исследования проводились сравнительная характеристика существующих методов бестраншейной прокладки трубопроводов, расчет основных характеристик подводного перехода, подбор защитного устройства, исследование напряженно-деформированного состояния трубопровода с помощью конечно-элементного моделирования в программном комплексе Ansys. В результате исследования подобраны оптимальные параметры подводного перехода, методом конечно-элементного моделирования в программном комплексе Ansys определено напряженно-деформированнон состояние трубопровода с защитным устройством и без него.The purpose of the work is to develop recommendations for the application of pipeline laying technology by the method of horizontal directional drilling using a protective device. In the process of the research, the existing methods of trenchless pipeline laying, the calculation of the main characteristics of the underwater crossing, the selection of the protective device, the study of the stress-strain state of the pipeline using finite element modeling in the software complex Ansys were compared. As a result of the research, optimal parameters of the underwater transition were selected, the finite element method in the software complex Ansys determined the stress-strain state of the pipeline with the protective device and without it
    corecore