436 research outputs found

    In Situ Investigations of Simultaneous Two-Layer Slot Die Coating of Component-Graded Anodes for Improved High-Energy Li-Ion Batteries

    Get PDF
    The use of thicker electrodes can contribute to a reduction in cell costs. However, the properties of the electrode must be kept in view to be able to meet the performance requirements. Herein, the possibility of simultaneous multilayer slot die coating is investigated to improve the electrode properties of medium- and high-capacity anodes. The stable coating window of the two-layer slot die coating process is investigated to produce property-graded multilayer electrodes. Electrodes with different styrene–butadiene rubber (SBR) gradients are investigated with regard to adhesive force and electrochemical performance. An increase in the adhesive force of up to 43.5% and an increase in the discharge capacity is observed

    Venous Leak Embolization in Patients with Venogenic Erectile Dysfunction via Deep Dorsal Penile Vein Access: Safety and Early Efficacy.

    Get PDF
    PURPOSE This all-comers registry aimed to assess safety and early efficacy of venous embolization in patients with venogenic erectile dysfunction due to venous leak in an unselected cohort. METHODS Between October 2019 and September 2022, patients with venogenic erectile dysfunction resistant to phosphodiesterase-5-inhibitors were treated with venous embolization using ultrasound-guided anterograde access via a deep dorsal penile vein in a single center. A mix of ethiodized oil and modified cyanoacrylate-based glue n-butyl 2 cyanoacrylate (NBCA) monomer plus methacryloxy-sulpholane monomer (Glubran-2, GEM, Italy) was used as liquid embolic agent. Prior to embolization, venous leak had been verified based on penile duplex sonography and computed tomography cavernosography. Procedural success was defined as technically successful and complete target vein embolization. The primary safety outcome measure was any major adverse event 6 weeks after the procedure. The primary feasibility outcome measure was IIEF-15 (International Index of Erectile Function-15) score improvement ≥ 4 points in ≥ 50% of subjects on 6 weeks follow-up post intervention. RESULTS Fifty consecutive patients (mean age 61.8 ± 10.0 years) with severe erectile dysfunction due to venous leak underwent venous embolization. Procedural success was achieved in 49/50 (98%) of patients with no major adverse events on follow-up. The primary feasibility outcome measure at 6 weeks was reached by 34/50 (68%) of patients. CONCLUSION Venous leak embolization via deep dorsal penile vein access using a liquid embolic agent was safe for all and efficacious in the majority of patients with severe venogenic erectile dysfunction on 6 weeks follow-up

    Leriche Syndrome

    Full text link

    A new efficient trial design for assessing reliability of ankle-brachial index measures by three different observer groups

    Get PDF
    BACKGROUND: The usual method of assessing the variability of a measure such as the ankle brachial index (ABI) as a function of different observer groups is to obtain repeated measurements. Because the number of possible observer-subject combinations is impractically large, only a few small studies on inter- and intraobserver variability of ABI measures have been carried out to date. The present study proposes a new and efficient study design. This paper describes the study methodology. METHODS: Using a partially balanced incomplete block design, six angiologists, six primary-care physicians and six trained medical office assistants performed two ABI measurements each on six individuals from a group of 36 unselected subjects aged 65–70 years. Each test subject is measured by one observer from each of the three observer groups, and each observer measures exactly six of the 36 subjects in the group. Each possible combination of two observers occurs exactly once per patient and is not repeated on a second subject. The study involved four groups of 36 subjects (144), plus standbys. RESULTS: The 192 volunteers present at the study day were similar in terms of demographic characteristics and vascular risk factors: mean age 68.6 ± 1.7; mean BMI 29.1 ± 4.6; mean waist-hip ratio 0.92 ± 0.09; active smokers 12%; hypertension 60.9%; hypercholesterolemia 53.4%; diabetic 17.2%. A complete set of ABI measurements (three observers performing two Doppler measurements each) was obtained from 108 subjects. From all other subjects at least one ABI measurement was obtained. The mean ABI was 1.08 (± 0.13), 15 (7.9%) volunteers had an ABI <0.9, and none had an ABI >1.4, i.e. a ratio that may be associated with increased stiffening of the arterial walls. CONCLUSION: This is the first large-scale study investigating the components of variability and thus reliability in ABI measurements. The advantage of the new study design introduced here is that only one sixth of the number of theoretically possible measurements is required to obtain information about measurement errors. Bland-Altman plots show that there are only small differences and no systematic bias between the observers from three occupational groups with different training backgrounds

    Dacron® vs. PTFE as bypass materials in peripheral vascular surgery – systematic review and meta-analysis

    Get PDF
    Roll S, Müller-Nordhorn J, Keil T, et al. Dacron® vs. PTFE as bypass materials in peripheral vascular surgery – systematic review and meta-analysis. BMC Surgery. 2008;8(1): 22.Background: In peripheral vascular bypass surgery different synthetic materials are available for bypass grafting. It is unclear which of the two commonly used materials, polytetrafluoroethylene (PTFE) or polyester (Dacron®) grafts, is to be preferred. Thus, the aim of this meta-analysis and systematic review was to compare the effectiveness of these two prosthetic bypass materials (Dacron® and PTFE). Methods: We performed a systematic literature search in MEDLINE, Cochrane-Library – CENTRAL, EMBASE and other databases for relevant publications in English and German published between 1999 and 2008. Only randomized controlled trials were considered for inclusion. We assessed the methodological quality by means of standardized checklists. Primary patency was used as the main endpoint. Random-effect meta-analysis as well as pooling data in life table format was performed to combine study results. Results: Nine randomized controlled trials (RCT) were included. Two trials showed statistically significant differences in primary patency, one favouring Dacron® and one favouring PTFE grafts, while 7 trials did not show statistically significant differences between the two materials. Meta-analysis on the comparison of PTFE vs. Dacron® grafts yielded no differences with regard to primary patency rates (hazard ratio 1.04 (95% confidence interval [0.85;1.28]), no significant heterogeneity (p = 0.32, I2 = 14%)). Similarly, there were no significant differences with regard to secondary patency rates. Conclusion: Systematic evaluation and meta-analysis of randomized controlled trials comparing Dacron® and PTFE as bypass materials for peripheral vascular surgery showed no evidence of an advantage of one synthetic material over the other

    Water displacement leg volumetry in clinical studies - A discussion of error sources

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Water displacement leg volumetry is a highly reproducible method, allowing the confirmation of efficacy of vasoactive substances. Nevertheless errors of its execution and the selection of unsuitable patients are likely to negatively affect the outcome of clinical studies in chronic venous insufficiency (CVI).</p> <p>Discussion</p> <p>Placebo controlled double-blind drug studies in CVI were searched (Cochrane Review 2005, MedLine Search until December 2007) and assessed with regard to efficacy (volume reduction of the leg), patient characteristics, and potential methodological error sources. Almost every second study reported only small drug effects (≤ 30 mL volume reduction). As the most relevant error source the conduct of volumetry was identified. Because the practical use of available equipment varies, volume differences of more than 300 mL - which is a multifold of a potential treatment effect - have been reported between consecutive measurements. Other potential error sources were insufficient patient guidance or difficulties with the transition from the Widmer CVI classification to the CEAP (Clinical Etiological Anatomical Pathophysiological) grading.</p> <p>Summary</p> <p>Patients should be properly diagnosed with CVI and selected for stable oedema and further clinical symptoms relevant for the specific study. Centres require a thorough training on the use of the volumeter and on patient guidance. Volumetry should be performed under constant conditions. The reproducibility of short term repeat measurements has to be ensured.</p

    Lifeworld Inc. : and what to do about it

    Get PDF
    Can we detect changes in the way that the world turns up as they turn up? This paper makes such an attempt. The first part of the paper argues that a wide-ranging change is occurring in the ontological preconditions of Euro-American cultures, based in reworking what and how an event is produced. Driven by the security – entertainment complex, the aim is to mass produce phenomenological encounter: Lifeworld Inc as I call it. Swimming in a sea of data, such an aim requires the construction of just enough authenticity over and over again. In the second part of the paper, I go on to argue that this new world requires a different kind of social science, one that is experimental in its orientation—just as Lifeworld Inc is—but with a mission to provoke awareness in untoward ways in order to produce new means of association. Only thus, or so I argue, can social science add to the world we are now beginning to live in

    Chapter VI: Follow-up after Revascularisation

    Get PDF
    AbstractStructured follow-up after revascularisation for chronic critical limb ischaemia (CLI) aims at sustained treatment success and continued best patient care. Thereby, efforts need to address three fundamental domains: (A) best medical therapy, both to protect the arterial reconstruction locally and to reduce atherosclerotic burden systemically; (B) surveillance of the arterial reconstruction; and (C) timely initiation of repeat interventions. As most CLI patients are elderly and frail, sustained resolution of CLI and preserved ambulatory capacity may decide over independent living and overall prognosis. Despite this importance, previous guidelines have largely ignored follow-up after CLI; arguably because of a striking lack of evidence and because of a widespread assumption that, in the context of CLI, efficacy of initial revascularisation will determine prognosis during the short remaining life expectancy. This chapter of the current CLI guidelines aims to challenge this disposition and to recommend evidentially best clinical practice by critically appraising available evidence in all of the above domains, including antiplatelet and antithrombotic therapy, clinical surveillance, use of duplex ultrasound, and indications for and preferred type of repeat interventions for failing and failed reconstructions. However, as corresponding studies are rarely performed among CLI patients specifically, evidence has to be consulted that derives from expanded patient populations. Therefore, most recommendations are based on extrapolations or subgroup analyses, which leads to an almost systematic degradation of their strength. Endovascular reconstruction and surgical bypass are considered separately, as are specific contexts such as diabetes or renal failure; and critical issues are highlighted throughout to inform future studies
    • …
    corecore