164 research outputs found

    SAFE - a Tool for Assessing the Sustainability of Agricultural Systems: an Illustration

    Get PDF
    SAFE (Framework for Assessing Sustainability levels) is a tool for evaluating the sustainability of agricultural systems and uses a hierarchical framework populated with indicators objectively selected by multicriteria evaluation. Indicators are measured at field, farm and landscape scales and progressively integrated into a global sustainability index (SI). SAFE is illustrated below with results on a field scale from a farm site

    SAFE: A Framework for Assessing Sustainability Levels in Agricultural Systems

    Get PDF
    Evaluating the sustainability of agricultural systems is a major challenge for scientists, policy makers and farmers. Numerous sets of indicators have recently been designed, both at national and international levels. However, most of these initiatives focus only on environmental aspects of sustainability, indicators are often selected arbitrarily and usually do not fit in a consistent, comprehensive and universally applicable framework. This paper presents an original framework for integrating the information contained by indicators into a single quantitative measure of agricultural sustainability in order to facilitate comparison and diagnosis

    The need for widely available genomic testing in rare eye diseases: an ERN-EYE position statement

    Get PDF
    BACKGROUND: Rare Eye Diseases (RED) are the leading cause of visual impairment and blindness for children and young adults in Europe. This heterogeneous group of conditions includes over 900 disorders ranging from relatively prevalent disorders such as retinitis pigmentosa to very rare entities such as developmental eye anomalies. A significant number of patients with RED have an underlying genetic etiology. One of the aims of the European Reference Network for Rare Eye Diseases (ERN–EYE) is to facilitate improvement in diagnosis of RED in European member states. MAIN BODY: Technological advances have allowed genetic and genomic testing for RED. The outcome of genetic testing allows better understanding of the condition and allows reproductive and therapeutic options. The increase of the number of clinical trials for RED has provided urgency for genetic testing in RED. A survey of countries participating in ERN-EYE demonstrated that the majority are able to access some forms of genomic testing. However, there is significant variability, particularly regarding testing as part of clinical service. Some countries have a well-delineated rare disease pathway and have a national plan for rare diseases combined or not with a national plan for genomics in medicine. In other countries, there is a well-established organization of genetic centres that offer reimbursed genomic testing of RED and other rare diseases. Clinicians often rely upon research-funded laboratories or private companies. Notably, some member states rely on cross-border testing by way of an academic research project. Consequently, many clinicians are either unable to access testing or are confronted with long turnaround times. Overall, while the cost of sequencing has dropped, the cumulative cost of a genomic testing service for populations remains considerable. Importantly, the majority of countries reported healthcare budgets that limit testing. SHORT CONCLUSION: Despite technological advances, critical gaps in genomic testing remain in Europe, especially in smaller countries where no formal genomic testing pathways exist. Even within larger countries, the existing arrangements are insufficient to meet the demand and to ensure access. ERN-EYE promotes access to genetic testing in RED and emphasizes the clinical need and relevance of genetic testing in RED

    The need for widely available genomic testing in rare eye diseases: an ERN-EYE position statement.

    Get PDF
    BACKGROUND: Rare Eye Diseases (RED) are the leading cause of visual impairment and blindness for children and young adults in Europe. This heterogeneous group of conditions includes over 900 disorders ranging from relatively prevalent disorders such as retinitis pigmentosa to very rare entities such as developmental eye anomalies. A significant number of patients with RED have an underlying genetic etiology. One of the aims of the European Reference Network for Rare Eye Diseases (ERN-EYE) is to facilitate improvement in diagnosis of RED in European member states. MAIN BODY: Technological advances have allowed genetic and genomic testing for RED. The outcome of genetic testing allows better understanding of the condition and allows reproductive and therapeutic options. The increase of the number of clinical trials for RED has provided urgency for genetic testing in RED. A survey of countries participating in ERN-EYE demonstrated that the majority are able to access some forms of genomic testing. However, there is significant variability, particularly regarding testing as part of clinical service. Some countries have a well-delineated rare disease pathway and have a national plan for rare diseases combined or not with a national plan for genomics in medicine. In other countries, there is a well-established organization of genetic centres that offer reimbursed genomic testing of RED and other rare diseases. Clinicians often rely upon research-funded laboratories or private companies. Notably, some member states rely on cross-border testing by way of an academic research project. Consequently, many clinicians are either unable to access testing or are confronted with long turnaround times. Overall, while the cost of sequencing has dropped, the cumulative cost of a genomic testing service for populations remains considerable. Importantly, the majority of countries reported healthcare budgets that limit testing. SHORT CONCLUSION: Despite technological advances, critical gaps in genomic testing remain in Europe, especially in smaller countries where no formal genomic testing pathways exist. Even within larger countries, the existing arrangements are insufficient to meet the demand and to ensure access. ERN-EYE promotes access to genetic testing in RED and emphasizes the clinical need and relevance of genetic testing in RED

    Clinical characteristics and natural history of rho-associated retinitis pigmentosa : a long-term follow-up study

    Get PDF
    Purpose: To investigate the natural history of RHO-associated retinitis pigmentosa (RP). Methods: A multicenter, medical chart review of 100 patients with autosomal dominant RHO-associated RP. Results: Based on visual fields, time-to-event analysis revealed median ages of 52 and 79 years to reach low vision (central visual field <20 degrees) and blindness (central visual field <10 degrees), respectively. For the best-corrected visual acuity (BCVA), the median age to reach mild impairment (20/67 <= BCVA < 20/40) was 72 years, whereas this could not be computed for lower acuities. Disease progression was significantly faster in patients with a generalized RP phenotype (n = 75; 75%) than that in patients with a sector RP phenotype (n = 25; 25%), in terms of decline rates of the BCVA (P < 0.001) and V4e retinal seeing areas (P < 0.005). The foveal thickness of the photoreceptor-retinal pigment epithelium (PR + RPE) complex correlated significantly with BCVA (Spearman's rho = 0.733; P < 0.001). Conclusion: Based on central visual fields, the optimal window of intervention for RHO-associated RP is before the 5th decade of life. Significant differences in disease progression are present between generalized and sector RP phenotypes. Our findings suggest that the PR + RPE complex is a potential surrogate endpoint for the BCVA in future studies

    Comparative Natural History of Visual Function From Patients With Biallelic Variants in BBS1 and BBS10.

    Get PDF
    The purpose of this study was to compare the natural history of visual function change in cohorts of patients affected with retinal degeneration due to biallelic variants in Bardet-Biedl syndrome genes: BBS1 and BBS10. Patients were recruited from nine academic centers from six countries (Belgium, Canada, France, New Zealand, Switzerland, and the United States). Inclusion criteria were: (1) female or male patients with a clinical diagnosis of retinal dystrophy, (2) biallelic disease-causing variants in BBS1 or BBS10, and (3) measures of visual function for at least one visit. Retrospective data collected included genotypes, age, onset of symptoms, and best corrected visual acuity (VA). When possible, data on refractive error, fundus images and autofluorescence (FAF), optical coherence tomography (OCT), Goldmann kinetic perimetry (VF), electroretinography (ERG), and the systemic phenotype were collected. Sixty-seven individuals had variants in BBS1 (n = 38; 20 female patients and 18 male patients); or BBS10 (n = 29; 14 female patients and 15 male patients). Missense variants were the most common type of variants for patients with BBS1, whereas frameshift variants were most common for BBS10. When ERGs were recordable, rod-cone dystrophy (RCD) was observed in 82% (23/28) of patients with BBS1 and 73% (8/11) of patients with BBS10; cone-rod dystrophy (CORD) was seen in 18% of patients with BBS1 only, and cone dystrophy (COD) was only seen in 3 patients with BBS10 (27%). ERGs were nondetectable earlier in patients with BBS10 than in patients with BBS1. Similarly, VA and VF declined more rapidly in patients with BBS10 compared to patients with BBS1. Retinal degeneration appears earlier and is more severe in BBS10 cases as compared to those with BBS1 variants. The course of change of visual function appears to relate to genetic subtypes of BBS

    Physical characteristics of the back are not predictive of low back pain in healthy workers: A prospective study

    Get PDF
    Background. In the working population, back disorders are an important reason for sick leave and permanent work inability. In the context of fitting the job to the worker, one of the primary tasks of the occupational health physician is to evaluate the balance between work-related and individual variables. Since this evaluation of work capacity often consists of a physical examination of the back, the objective of this study was to investigate whether a physical examination of the low back, which is routinely performed in occupational medicine, predicts the development of low back pain (LBP). Methods. This study is part of the Belgian Low Back Cohort (BelCoBack) Study, a prospective study to identify risk factors for the development of low back disorders in occupational settings. The study population for this paper were 692 young healthcare or distribution workers (mean age of 26 years) with no or limited back antecedents in the year before inclusion. At baseline, these workers underwent a standardised physical examination of the low back. One year later, they completed a questionnaire on the occurrence of LBP and some of its characteristics. To study the respective role of predictors at baseline on the occurrence of LBP, we opted for Cox regression with a constant risk period. Analyses were performed separately for workers without any back antecedents in the year before inclusion ('asymptomatic' workers) and for workers with limited back antecedents in the year before inclusion ('mildly symptomatic' workers). Results. In the group of 'asymptomatic' workers, obese workers showed a more than twofold-increased risk on the development of LBP as compared to non-obese colleagues (RR 2.57, 95%CI: 1.09 - 6.09). In the group of 'mildly symptomatic' workers, the self-reports of pain before the examination turned out to be most predictive (RR 3.89, 95%CI: 1.20 - 12.64). Conclusion. This study showed that, in a population of young workers wh no or limited antecedents of LBP at baseline, physical examinations, as routinely assessed in occupational medicine, are not useful to predict workers at risk for the development of back disorders one year later

    The Natural History of Leber Congenital Amaurosis and Cone-Rod Dystrophy Associated with Variants in the GUCY2D Gene

    Get PDF
    OBJECTIVE: To describe the spectrum of Leber congenital amaurosis (LCA) and cone-rod dystrophy (CORD) associated with the GUCY2D gene, and to identify potential clinical endpoints and optimal patient selection for future therapeutic trials. DESIGN: International multicenter retrospective cohort study. SUBJECTS: 82 patients with GUCY2D-associated CORD and LCA from 54 molecularly confirmed families. METHODS: Data were gathered by reviewing medical records for medical history, symptoms, best-corrected visual acuity (BCVA), ophthalmoscopy, visual fields, full-field electroretinography and retinal imaging (fundus photography, spectral-domain optical coherence tomography (SD-OCT), fundus autofluorescence). MAIN OUTCOMES MEASURES: Age of onset, annual decline of visual acuity, estimated visual impairment per age, genotype-phenotype correlations, anatomic characteristics on funduscopy, and multimodal imaging. RESULTS: Fourteen patients with autosomal recessive LCA and 68 with autosomal dominant CORD were included. The median follow-up time was 5.2 years (interquartile range (IQR), 2.6-8.8) for LCA, and 7.2 years (IQR, 2.2-14.2) for CORD. Generally, LCA presented in the first year of life. The BCVA in LCA ranged from no light perception to 1.00 logMAR, and remained relatively stable during follow-up. Imaging for LCA was limited, but showed little to no structural degeneration. In CORD, progressive vision loss started around the second decade of life. The annual decline rate of visual acuity was 0.022 logMAR (P A and the c.2512C>T GUCY2D variant (P = 0.798). At the age of 40 years the probability of being blind or severely visually impaired was 32%. The integrity of the ellipsoid zone (EZ) and external limiting membrane (ELM) on SD-OCT were correlated significantly with BCVA (Spearman's ρ = 0.744, P = 0.001 and ρ = 0.712, P < 0.001, respectively) in CORD. CONCLUSION: LCA due to variants in GUCY2D results in severe congenital visual impairment with relatively intact macular anatomy on funduscopy and available imaging, suggesting a long preservation of photoreceptors. Despite large variability, GUCY2D-associated CORD generally presented during adolescence with a progressive loss of vision and culminated in severe visual impairment during mid to late-adulthood. The integrity of the ELM and EZ may be suitable structural endpoints for therapeutic studies in GUCY2D-associated CORD

    Performance of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System

    Full text link
    Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for the GE1/1 system in the 1.5<η<2.21.5 < \mid\eta\mid < 2.2 region of the muon endcap mainly to control muon level-1 trigger rates after the second long LHC shutdown. A GE1/1 triple-GEM detector is read out by 3,072 radial strips with 455 μ\murad pitch arranged in eight η\eta-sectors. We assembled a full-size GE1/1 prototype of 1m length at Florida Tech and tested it in 20-120 GeV hadron beams at Fermilab using Ar/CO2_{2} 70:30 and the RD51 scalable readout system. Four small GEM detectors with 2-D readout and an average measured azimuthal resolution of 36 μ\murad provided precise reference tracks. Construction of this largest GEM detector built to-date is described. Strip cluster parameters, detection efficiency, and spatial resolution are studied with position and high voltage scans. The plateau detection efficiency is [97.1 ±\pm 0.2 (stat)]\%. The azimuthal resolution is found to be [123.5 ±\pm 1.6 (stat)] μ\murad when operating in the center of the efficiency plateau and using full pulse height information. The resolution can be slightly improved by \sim 10 μ\murad when correcting for the bias due to discrete readout strips. The CMS upgrade design calls for readout electronics with binary hit output. When strip clusters are formed correspondingly without charge-weighting and with fixed hit thresholds, a position resolution of [136.8 ±\pm 2.5 stat] μ\murad is measured, consistent with the expected resolution of strip-pitch/12\sqrt{12} = 131.3 μ\murad. Other η\eta-sectors of the detector show similar response and performance.Comment: 8 pages, 32 figures, submitted to Proc. 2014 IEEE Nucl. Sci. Symposium, Seattle, WA, reference adde

    Quality control and beam test of GEM detectors for future upgrades of the CMS muon high rate region at the LHC

    Get PDF
    Gas Electron Multipliers (GEM) are a proven position sensitive gas detector technology which nowadays is becoming more widely used in High Energy Physics. GEMs offer an excellent spatial resolution and a high particle rate capability, with a close to 100% detection efficiency. In view of the high luminosity phase of the CERN Large Hadron Collider, these aforementioned features make GEMs suitable candidates for the future upgrades of the Compact Muon Solenoid (CMS) detector. In particular, the CMS GEM Collaboration proposes to cover the high-eta region of the muon system with large-area triple-GEM detectors, which have the ability to provide robust and redundant tracking and triggering functions. In this contribution, after a general introduction and overview of the project, the construction of full-size trapezoidal triple-GEM prototypes will be described in more detail. The procedures for the quality control of the GEM foils, including gain uniformity measurements with an x-ray source will be presented. In the past few years, several CMS triple-GEM prototype detectors were operated with test beams at the CERN SPS. The results of these test beam campaigns will be summarised
    corecore