889 research outputs found

    Pathways to strengthening midwifery in Europe

    Get PDF

    Mechanical Behavior of Microelectromechanical Microshutters

    Get PDF
    A custom micro-mechanical test system was constructed using off-the-shelf components to characterize the mechanical properties of microshutters. Microshutters are rectangular microelectromechanical apertures which open and close about a narrow torsion bar hinge. Displacement measurements were verified using both capacitive and digital image correlation techniques. Repeatable experiments on Si3N4 cantilever beams verified that the test system operates consistently. Using beam theory, the modulus of elasticity of the low stress Si3N4 was approximately 150 GPa, though significant uncertainty exists for this measurement due primarily to imprecise knowledge of the cantilever thickness. Tests conducted on microshutter arrays concluded that reducing the Si3N4 thickness from 250 nm to 500 nm reduces the torsional stiffness by a factor of approximately four. This is in good agreement with analytical and finite element models of the microshutters

    Fracture Detection using Amplitude versus Offset and Azimuth Analysis of a 3D P-wave Seismic Dataset and Synthetic Examples

    Get PDF
    Amplitude versus offset (AVO) analysis of seismic reflection data has been a successful tool in describing changes in rock properties along a reflector. This method is extended to azimuthal AVO (AVOA) in order to characterize vertically aligned fractures within a reservoir, which can be important fluid migration pathways. AVOA analysis is performed on synthetic data using a least squares inversion method to investigate the effects of varying acquisition geometry, amount of noise, and fracture properties. These tests show that it is possible to detect the fractured layer and determine the fracture strike orientation under typical acquisition conditions. This method is also applied to field data collected during an Ocean Bottom Cable (OBC) survey. These data include a broad offset-azimuth range, which is important for the AVOA analysis. The fracture location and strike orientation recovered from the field data analysis are well correlated with borehole information from this area. Based on an understanding of AVOA behavior under synthetic conditions, this technique provides an effective methodology for describing the spatial variability of a fractured reservoir using 3D seismic data.Eni S.p.A. (Firm)United States. Dept. of Energy (Grant number DE-FC26-02NT15346)Massachusetts Institute of Technology. Earth Resources Laborator

    Iso-osmotic regulation of nitrate accumulation in lettuce (Lactuca sativa L.)

    Get PDF
    Concerns about possible health hazards arising from human consumption of lettuce and other edible vegetable crops with high concentrations of nitrate have generated demands for a greater understanding of processes involved in its uptake and accumulation in order to devise more sustainable strategies for its control. This paper evaluates a proposed iso-osmotic mechanism for the regulation of nitrate accumulation in lettuce (Lactuca sativa L.) heads. This mechanism assumes that changes in the concentrations of nitrate and all other endogenous osmotica (including anions, cations and neutral solutes) are continually adjusted in tandem to minimise differences in osmotic potential of the shoot sap during growth, with these changes occurring independently of any variations in external water potential. The hypothesis was tested using data from six new experiments, each with a single unique treatment comprising a separate combination of light intensity, N source (nitrate with or without ammonium) and nitrate concentration carried out hydroponically in a glasshouse using a butterhead lettuce variety. Repeat measurements of plant weights and estimates of all of the main soluble constituents (nitrate, potassium, calcium, magnesium, organic anions, chloride, phosphate, sulphate and soluble carbohydrates) in the shoot sap were made at intervals from about 2 weeks after transplanting until commercial maturity, and the data used to calculate changes in average osmotic potential in the shoot. Results showed that nitrate concentrations in the sap increased when average light levels were reduced by between 30 and 49 % and (to a lesser extent) when nitrate was supplied at a supra-optimal concentration, and declined with partial replacement of nitrate by ammonium in the external nutrient supply. The associated changes in the proportions of other endogenous osmotica, in combination with the adjustment of shoot water content, maintained the total solute concentrations in shoot sap approximately constant and minimised differences in osmotic potential between treatments at each sampling date. There was, however, a gradual increase in osmotic potential (ie a decline in total solute concentration) over time largely caused by increases in shoot water content associated with the physiological and morphological development of the plants. Regression analysis using normalised data (to correct for these time trends) showed that the results were consistent with a 1:1 exchange between the concentrations of nitrate and the sum of all other endogenous osmotica throughout growth, providing evidence that an iso-osmotic mechanism (incorporating both concentration and volume regulation) was involved in controlling nitrate concentrations in the shoot

    Labouring women who used a birthing pool in obstetric units in Italy: prospective observational study

    Get PDF
    Background For women at low risk of childbirth complications, water immersion during labour is a care option in many high income countries. Our aims were (a) to describe maternal characteristics, intrapartum events, interventions, maternal and neonatal outcomes for all women who used a birthing pool during labour who either had a waterbirth or left the pool and had a landbirth, and for the subgroup of women who had a waterbirth in 19 obstetric units, and (b) to compare maternal characteristics, intrapartum events, interventions, and maternal and neonatal outcomes for women who used a birthing pool with a control group of women who did not use a birthing pool for whom we prospectively collected data in a single centre. Methods Prospective observational study in 19 Italian obstetric units 2002-2005. Participants were: (a) 2,505 women in labour using a birthing pool in 19 obstetric units; and (b) 114 women in labour using a birthing pool and 459 women who did not use a birthing pool in one obstetric unit. Descriptive statistics were calculated for the sample as a whole and, separately, for those women who gave birth in water. Categorical data were compared using Chi square statistics and continuous data by T-tests. Results Overall, 95.6% of women using a birthing pool had a spontaneous vertex delivery, 63.9% of which occurred in water. Half of nulliparas and three quarters of multiparas delivered in water. Adverse maternal and neonatal outcomes were rare. There were two cases of umbilical cord snap with waterbirth. Compared with controls, significantly more women who used a birthing pool adopted an upright birth position, had hands off delivery technique, and a physiological third stage. Significantly fewer nulliparas had an episiotomy, and more had a second degree perineal tear, with no evidence of a difference for extensive perineal tears. Conclusions Birthing pool use was associated with spontaneous vaginal birth. The increase in second degree tears was balanced by fewer episiotomies. Undue umbilical cord traction should be avoided during waterbirth

    2D Electrostatic Actuation of Microshutter Arrays

    Get PDF
    An electrostatically actuated microshutter array consisting of rotational microshutters (shutters that rotate about a torsion bar) were designed and fabricated through the use of models and experiments. Design iterations focused on minimizing the torsional stiffness of the microshutters, while maintaining their structural integrity. Mechanical and electromechanical test systems were constructed to measure the static and dynamic behavior of the microshutters. The torsional stiffness was reduced by a factor of four over initial designs without sacrificing durability. Analysis of the resonant behavior of the microshutter arrays demonstrates that the first resonant mode is a torsional mode occurring around 3000 Hz. At low vacuum pressures, this resonant mode can be used to significantly reduce the drive voltage necessary for actuation requiring as little as 25V. 2D electrostatic latching and addressing was demonstrated using both a resonant and pulsed addressing scheme

    Reliability of capturing foot parameters using digital scanning and the neutral suspension casting technique

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>A clinical study was conducted to determine the intra and inter-rater reliability of digital scanning and the neutral suspension casting technique to measure six foot parameters. The neutral suspension casting technique is a commonly utilised method for obtaining a negative impression of the foot prior to orthotic fabrication. Digital scanning offers an alternative to the traditional plaster of Paris techniques.</p> <p>Methods</p> <p>Twenty one healthy participants volunteered to take part in the study. Six casts and six digital scans were obtained from each participant by two raters of differing clinical experience. The foot parameters chosen for investigation were cast length (mm), forefoot width (mm), rearfoot width (mm), medial arch height (mm), lateral arch height (mm) and forefoot to rearfoot alignment (degrees). Intraclass correlation coefficients (ICC) with 95% confidence intervals (CI) were calculated to determine the intra and inter-rater reliability. Measurement error was assessed through the calculation of the standard error of the measurement (SEM) and smallest real difference (SRD).</p> <p>Results</p> <p>ICC values for all foot parameters using digital scanning ranged between 0.81-0.99 for both intra and inter-rater reliability. For neutral suspension casting technique inter-rater reliability values ranged from 0.57-0.99 and intra-rater reliability values ranging from 0.36-0.99 for rater 1 and 0.49-0.99 for rater 2.</p> <p>Conclusions</p> <p>The findings of this study indicate that digital scanning is a reliable technique, irrespective of clinical experience, with reduced measurement variability in all foot parameters investigated when compared to neutral suspension casting.</p
    corecore