459 research outputs found

    Performance evaluation of fifth-generation ultra-high-resolution SPECT system with two stationary detectors and multi-pinhole imaging

    Get PDF
    Background Small-animal single-photon emission computed tomography (SPECT) systems with multi-pinhole collimation and large stationary detectors have advantages compared to systems with moving small detectors. These systems benefit from less labour-intensive maintenance and quality control as fewer prone parts are moving, higher accuracy for focused scans and maintaining high resolution with increased sensitivity due to focused pinholes on the field of view. This study aims to investigate the performance of a novel ultra-high-resolution scanner with two-detector configuration (U-SPECT5-E) and to compare its image quality to a conventional micro-SPECT system with three stationary detectors (U-SPECT+). Methods The new U-SPECT5-E with two stationary detectors was used for acquiring data with Tc-99m-filled point source, hot-rod and uniformity phantoms to analyse sensitivity, spatial resolution, uniformity and contrast-to-noise ratio (CNR). Three dedicated multi-pinhole mouse collimators with 75 pinholes each and 0.25-, 0.60- and 1.00-mm pinholes for extra ultra-high resolution (XUHR-M), general-purpose (GP-M) and ultra-high sensitivity (UHS-M) imaging were examined. For CNR analysis, four different activity ranges representing low- and high-count settings were investigated for all three collimators. The experiments for the performance assessment were repeated with the same GP-M collimator in the three-detector U-SPECT+ for comparison. Results Peak sensitivity was 237 cps/MBq (XUHR-M), 847 cps/MBq (GP-M), 2054 cps/MBq (UHS-M) for U-SPECT5-E and 1710 cps/MBq (GP-M) for U-SPECT+. In the visually analysed sections of the reconstructed mini Derenzo phantoms, rods as small as 0.35 mm (XUHR-M), 0.50 mm (GP-M) for the two-detector as well as the three-detector SPECT and 0.75 mm (UHS-M) were resolved. Uniformity for maximum resolution recorded 40.7% (XUHR-M), 29.1% (GP-M, U-SPECT5-E), 16.3% (GP-M, U-SPECT+) and 23.0% (UHS-M), respectively. UHS-M reached highest CNR values for low-count images; for rods smaller than 0.45 mm, acceptable CNR was only achieved by XUHR-M. GP-M was superior for imaging rods sized from 0.60 to 1.50 mm for intermediate activity concentrations. U-SPECT5-E and U-SPECT+ both provided comparable CNR. Conclusions While uniformity and sensitivity are negatively affected by the absence of a third detector, the investigated U-SPECT5-E system with two stationary detectors delivers excellent spatial resolution and CNR comparable to the performance of an established three-detector-setup

    Cloning of a Gene for an Acyl-CoA Dehydrogenase from Pisum sativum L. and Purification and Characterization of Its Product as an Isovaleryl-CoA Dehydrogenase

    Get PDF
    Isovaleryl-CoA dehydrogenase (IVD, EC 1.3.99.10) catalyzes the third step in the catabolism of leucine in mammals. Deficiency of this enzyme leads to the clinical disorder isovaleric acidemia. IVD has been purified and characterized from human and rat liver, and the x-ray crystallographic structure of purified recombinant human IVD has been reported. Nothing is known about IVD activity in plants, although cDNA clones from Arabidopsis thaliana and partial sequences from Gossypium hirsutum and Oryza sativa have been identified as putative IVDs based on sequence homology and immuno cross-reactivity. In this report we describe the identification and characterization of an IVD from pea, purification of the enzyme using a novel and rapid auxin affinity chromatography matrix, and cloning of the corresponding gene. At the amino acid level, pea IVD is 60% similar to human and rat IVD. The specific activity and abundance of plant IVD was found to be significantly lower than for its human counterpart and exhibits developmental regulation. Substrate specificity of the plant enzyme is similar to the human IVD, and it cross-reacts to anti-human IVD antibodies. Molecular modeling of the pea enzyme based on the structure of human IVD indicates a high degree of structural similarity among these enzymes. Glu-244, shown to function as the catalytic base in human IVD along with most of the amino acids that make up the acyl CoA binding pocket, is conserved in pea IVD. The genomic structure of the plant IVD gene consists of 13 exons and 12 introns, spanning approximately 4 kilobases, and the predicted RNA splicing sites exhibit the extended consensus sequence described for other plant genes

    30-days mortality in patients with perforated peptic ulcer: A national audit

    Get PDF
    Anne Nakano1,4, Jørgen Bendix2, Sven Adamsen3, Daniel Buck4, Jan Mainz5, Paul Bartels1, Bente Nørgård4,61The Danish National Indicator Project, Regionshuset Aarhus, Aarhus, Denmark; 2Department of Gastrointestinal Surgery L, Aarhus University Hospital, Denmark; 3Digestive Disease Center, Section for Gastrointestinal Surgery, Copenhagen, Denmark; University Hospital Herlev, Denmark; 4Department of Clinical Epidemiology, Aarhus University Hospital, Aarhus, Denmark; 5Department of Psychiatry Region North, Denmark and Institute of Public Health, University of Southern Denmark, Odense, Denmark; 6Center for National Clinical Databases, South, Odense University Hospital, and Epidemiology, Institute of Public Health, University of Southern Denmark, Odense, DenmarkBackground: In 2005, The Danish National Indicator Project (DNIP) reported findings on patients hospitalized with perforated ulcer. The indicator “30-days mortality” showed major discrepancy between the observed mortality of 28% and the chosen standard (10%).Rationale: An audit committee was appointed to examine quality problems linked to the high mortality. The purpose was to (i) examine patient characteristics, (ii) evaluate the appropriateness of the standard, and (iii) audit all cases of deaths within 30 days after surgery.Methods: Four hundred and twelve consecutive patients were included and used for the analyses of patient characteristics. The evaluation of the standard was based on a literature review, and a structured audit was performed according to the 115 deaths that occurred.Results: The mean age was 69.1 years, 42.0% had one co-morbid disease and 17.7% had two co-morbid diseases. 45.9% had an American Association of Anaesthetists score of 3–4. We found no results on mortality in studies similar to ours. The audit process indicated that the postoperative observation of patients was insufficient.Discussion: As a result of this study, the standard for mortality was increased to 20%, and the new indicators for postoperative monitoring were developed. The DNIP continues to evaluate if these initiatives will improve the results on mortality.Keywords: mortality, perforated peptic ulcer, ulcer, audi

    Capabilities of multi-pinhole SPECT with two stationary detectors for in vivo rat imaging

    Get PDF
    We aimed to investigate the image quality of the U-SPECT5/CT E-Class a micro single-photon emission computed tomography (SPECT) system with two large stationary detectors for visualization of rat hearts and bones using clinically available Tc-99m-labelled tracers. Sensitivity, spatial resolution, uniformity and contrast-to-noise ratio (CNR) of the small-animal SPECT scanner were investigated in phantom studies using an ultra-high-resolution rat and mouse multi-pinhole collimator (UHR-RM). Point source, hot-rod, and uniform phantoms with Tc-99m-solution were scanned for high-count performance assessment and count levels equal to animal scans, respectively. Reconstruction was performed using the similarity-regulated ordered-subsets expectation maximization (SROSEM) algorithm with Gaussian smoothing. Rats were injected with similar to 100 MBq [Tc-99m]Tc-MIBI or similar to 150 MBq [Tc-99m]Tc-HMDP and received multi-frame micro-SPECT imaging after tracer distribution. Animal scans were reconstructed for three different acquisition times and post-processed with different sized Gaussian filters. Following reconstruction, CNR was calculated and image quality evaluated by three independent readers on a five-point scale from 1="very poor" to 5="very good". Point source sensitivity was 567 cps/MBq and radioactive rods as small as 1.2 mm were resolved with the UHR-RM collimator. Collimator-dependent uniformity was 55.5%. Phantom CNR improved with increasing rod size, filter size and activity concentration. Left ventricle and bone structures were successfully visualized in rat experiments. Image quality was strongly affected by the extent of post-filtering, whereas scan time did not have substantial influence on visual assessment. Good image quality was achieved for resolution range greater than 1.8 mm in bone and 2.8 mm in heart. The recently introduced small animal SPECT system with two stationary detectors and UHR-RM collimator is capable to provide excellent image quality in heart and bone scans in a rat using standardized reconstruction parameters and appropriate post-filtering. However, there are still challenges in achieving maximum system resolution in the sub-millimeter range with in vivo settings under limited injection dose and acquisition time

    Production and application of stable isotope-labeled internal standards for RNA modification analysis

    Get PDF
    Post-transcriptional RNA modifications have been found to be present in a wide variety of organisms and in different types of RNA. Nucleoside modifications are interesting due to their already known roles in translation fidelity, enzyme recognition, disease progression, and RNA stability. In addition, the abundance of modified nucleosides fluctuates based on growth phase, external stress, or possibly other factors not yet explored. With modifications ever changing, a method to determine absolute quantities for multiple nucleoside modifications is required. Here, we report metabolic isotope labeling to produce isotopically labeled internal standards in bacteria and yeast. These can be used for the quantification of 26 different modified nucleosides. We explain in detail how these internal standards are produced and show their mass spectrometric characterization. We apply our internal standards and quantify the modification content of transfer RNA (tRNA) from bacteria and various eukaryotes. We can show that the origin of the internal standard has no impact on the quantification result. Furthermore, we use our internal standard for the quantification of modified nucleosides in mouse tissue messenger RNA (mRNA), where we find different modification profiles in liver and brain tissue

    Pulmonary vasculitis due to infection with Mycobacterium goodii : A case report

    Get PDF
    A 57-year-old Caucasian woman suffered from dyspnea on exertion. One year following a supposed pulmonary embolism event, a chronic thromboembolic vasculopathy was diagnosed and a pulmonary thromboendarterectomy was performed. However, a granulomatous pulmonary arterial vasculitis was identified upon examination. DNA of Mycobacterium goodii was detected as the most likely causative agent. Anti-inflammatory and anti-mycobacterial therapy was initiated for more than 12 months. Regular PET-CT scans revealed improvement under therapy. The last PET-CT did not show any tracer uptake following 10 months of therapy
    corecore